![](http://datasheet.mmic.net.cn/120000/TPS70702PWP_datasheet_3584259/TPS70702PWP_3.png)
www.ti.com
ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATINGS
TPS70745, TPS70748
TPS70751, TPS70758
TPS70702
SLVS291D – MAY 2000 – REVISED DECEMBER 2007
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION(1)
VOLTAGE (V)(2)
PACKAGE-
SPECIFIED
LEAD
TEMPERATURE
ORDERING
TRANSPORT
PRODUCT
VOUT1
VOUT2
(DESIGNATOR)
RANGE (TJ)
NUMBER
MEDIA, QUANTITY
TPS70702PWP
Tube, 70
TPS70702
Adjustable
HTSSOP-24 (PWP)
-40
°C to +125°C
TPS70702PWPR
Tape and Reel, 2000
TPS70745PWP
Tube, 70
TPS70745
3.3 V
1.2 V
HTSSOP-24 (PWP)
-40
°C to +125°C
TPS70745PWPR
Tape and Reel, 2000
TPS70748PWP
Tube, 70
TPS70748
3.3 V
1.5 V
HTSSOP-24 (PWP)
-40
°C to +125°C
TPS70748PWPR
Tape and Reel, 2000
TPS70751PWP
Tube, 70
TPS70751
3.3 V
1.8 V
HTSSOP-24 (PWP)
-40
°C to +125°C
TPS70751PWPR
Tape and Reel, 2000
TPS70758PWP
Tube, 70
TPS70758
3.3 V
2.5 V
HTSSOP-24 (PWP)
-40
°C to +125°C
TPS70758PWPR
Tape and Reel, 2000
(1)
For the most current package and ordering information see the Package Option Addendum located at the end of this document, or see
(2)
For fixed 1.20V operation, tie FB to OUT.
Over operating free-air temperature range (unless otherwise noted)
(1)
TPS707xx
UNIT
Input voltage range: VIN1, VIN2
(2)
–0.3 to +7
V
Voltage range at EN
–0.3 to +7
V
Output voltage range (VOUT1, VSENSE1)
5.5
V
Output voltage range (VOUT2, VSENSE2)
5.5
V
Maximum RESET, PG1 voltage
7
V
Maximum MR1, MR2, and SEQ voltage
VIN1
V
Peak output current
Internally limited
Continuous total power dissipation
See Dissipation Ratings Table
Junction temperature range, TJ
–40 to +150
°C
Storage temperature range, Tstg
–65 to +150
°C
ESD rating, HBM
2
kV
(1)
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2)
All voltages are tied to network ground.
DERATING
PACKAGE
AIR FLOW (CFM)
TA ≤ +25°C
FACTOR
TA = +70°C
TA = +85°C
0
3.067W
30.67mW/
°C
1.687W
1.227W
PWP(1)
250
4.115W
41.15mW/
°C
2.265W
1.646W
(1)
This parameter is measured with the recommended copper heat sink pattern on a 4-layer PCB, 1 oz. copper on a 4-in by 4-in ground
layer. For more information, refer to TI technical brief
SLMA002.
Copyright 2000–2007, Texas Instruments Incorporated
3