6
W.FL2 SeriesqUltra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
The contents of this catalog are current as of date of publication. Contents are subject to change without notice for the purpose of improvements.
5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8587,JAPAN
PHONE: 81-3-3491-9741, FAX: 81-3-3493-2933
http://www.hirose.com
http://www.hirose-connectors.com
sPrecautions
1. Plugs
qUse of the extraction tool is absolutely
mandatory. Any attempt of unmating by
pulling on the cable may result in damage
and affect the mechanical / electrical
performance.
Unmating
Mating
Plug
(1) Recommended reflow
temperature profile
q The temperature of the printed circuit board surface
temperature at the points of contact with the terminals.
w Reflow soldering should be performed at a printed
circuit surface temperature of 250°C max.
e In individual applications the actual temperature may
vary, depending on the solder paste type, volume /
thickness and board size / thickness. Consuly your
solder paste and equipment manufacturer for specific
recommendations.
(2) Recommended metal mask thickness
(3) Reflow cycles
2. Receptacles
80
100
120
140
160
180
200
220
240
260
[]
Preheat
(130 to 180)
230
220
50 seconds max.
120 seconds max.
60 seconds max.
Time
250 max. for
10 seconds
(1) Mating / unmating
(3) Precautions
q Align the mating tool W.FL-LP-IN or the
mating end of the tool W.FL2-LP-IN.OUT over
the plug end of the cable assembly.
w Firmly place the tool over the plug until it is
secured in the tool.
e Place the plug cable assembly (held in the
tool) over the corresponding receptacle.
r Assuring that the plug and receptacle are
aligned press-down perpendicular to the
mounting surface until both connectors are
fully mated.
t Remove the mating tool by carefully pulling it
up.Removal of the tool
q To disconnect connectors, insert the extraction side of insertion and extraction jig W.FL2-LP-IN.OUT and perform as
described in the diagram below.
Do not twist connectors excessively during mating / unmating.
qw
W.FL2-LP-040 (Plug)
W. FL2-R-SMT-1:
qwert
Do NOT apply any pull forces after the
bending of the cable.
(2) Pull forces on the
cable after connectors
are mated
0.1 mm to 0.12 mm
2 times
(1) Operating environment
The connectors are NOT designed to operate in the following environments:
Exposed to a excessive amounts of fine particles and dust
Regions and places having a high density of sulfur dioxide, hydrogen sulfide, nitrogen dioxide or other corrosive gasses.
Environments having large rapid variations in temperature.
(2) Storage conditions -
Receptacle
Store in the Hirose Electric packaging.
Temperature: -10 to +40, Humidity: 85% max.
Use within 6 months of delivery.
Receptacles for which the storage period has elapsed must be tested for solderability to the PC board mounting surface.
3. Operating environment and storage conditions
W.FL2-LP-040
2 N max.
W.FL2-R-SMT-1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.