参数资料
型号: XR19L210IL40-0A-EB
厂商: Exar Corporation
文件页数: 3/43页
文件大小: 0K
描述: EVAL BOARD FOR XR19L202 40QFN
标准包装: 1
系列: *
XR19L210
11
REV. 1.0.2
SINGLE CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
upon receiving a character or delay until it reaches the FIFO trigger level. Furthermore, data delivery to the
host is guaranteed by a receive data ready time-out interrupt when data is not received for 4 word lengths as
defined by LCR[1:0] plus 12 bits time. This is equivalent to 3.7-4.6 character times. The RHR interrupt is
enabled by IER bit-0.
2.11.1
Receive Holding Register (RHR) - Read-Only
The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift
Register. It provides the receive data interface to the host processor. The RHR register is part of the receive
FIFO of 16 bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When
the FIFO is enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the
RHR is read, the next character byte is loaded into the RHR and the errors associated with the current data
byte are immediately updated in the LSR bits 2-4.
FIGURE 8. RECEIVER OPERATION IN NON-FIFO MODE
FIGURE 9. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE
Receive Data Shift
Register (RSR)
Receive
Data Byte
and Errors
RHR Interrupt (ISR bit-2)
Receive Data
Holding Register
(RHR)
RXFIFO1
16X Clock
Receive Data Characters
Data Bit
Validation
Error
Tags in
LSR bits
4:2
Receive Data Shift
Register (RSR)
RXFIFO1
16X Clock
E
rror
Tags
(16-sets)
E
rror
Tags
in
LS
R
b
its
4:2
16 bytes by 11-bit
wide
FIFO
Receive Data Characters
FIFO Trigger=8
Example
:
RX FIFO trigger level selected at 8 bytes
Data fills to
14
Data falls to
4
Data Bit
Validation
Receive
Data FIFO
Receive
Data
Receive Data
Byte and Errors
RHR Interrupt (ISR bit-2) programmed for
desired FIFO trigger level.
FIFO is Enabled by FCR bit-0=1
RTS# de-asserts when data fills above the flow
control trigger level to suspend remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
RTS# re-asserts when data falls below the flow
control trigger level to restart remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
相关PDF资料
PDF描述
VI-JTT-EZ-S CONVERTER MOD DC/DC 6.5V 25W
6374109-7 C/A 62.5/125 1.6MM LC 0.34M
XR19L200IL32-0A-EB EVAL BOARD FOR XR19L200 32QFN
6374611-1 C/A 2.0MM SM LC-SC 1M1
RBC15DCST-S288 CONN EDGECARD 30POS .100 EXTEND
相关代理商/技术参数
参数描述
XR19L210IL40-0B-EB 功能描述:界面开发工具 Supports L210 40 pin QFN, PCI Interface RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XR19L210IL40-F 功能描述:UART 接口集成电路 UART RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel
XR19L212 制造商:EXAR 制造商全称:EXAR 功能描述:TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
XR19L212IL48 制造商:EXAR 制造商全称:EXAR 功能描述:TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
XR19L212IL48-0B-EB 功能描述:界面开发工具 Supports L212 48 pin QFN, PCI Interface RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V