参数资料
型号: XRT73L03BIV-F
厂商: Exar Corporation
文件页数: 40/61页
文件大小: 0K
描述: IC LIU E3/DS3/STS-1 3CH 120LQFP
标准包装: 72
类型: 线路接口装置(LIU)
驱动器/接收器数: 3/3
规程: DS3,E3,STS-1
电源电压: 3.135 V ~ 3.465 V
安装类型: 表面贴装
封装/外壳: 120-LQFP
供应商设备封装: 120-LQFP(14x20)
包装: 托盘
XRT73L03B
3 CHANNEL DS3/E3/STS-1 LINE INTERFACE UNIT
REV. 1.0.1
43
forced to "0". Once the LOS condition has been
cleared, then the channel(n) resumes normal trans-
mission of the recovered data to the Receiving Termi-
nal.
This feature is available whenever XRT73L03B is op-
erating in the HOST Mode or Hardware Mode.
a. Operating in the Hardware Mode.
The Muting upon LOS feature is enabled by pulling
the LOSMUTEN output pin “High". This enables the
Muting upon LOS feature globally for all channels.
b. Operating in the HOST Mode.
The Muting upon LOS feature for each Channel can
be enabled by writing a "1" into the LOSMUT_(n) bit-
field within Command Register 3.
NOTE: This step only enables the Muting upon LOS feature
within Channel(n).
3.6
ROUTING THE RECOVERED TIMING AND DATA
INFORMATION TO THE RECEIVING TERMINAL
EQUIPMENT
Each channel takes the Recovered Timing and Data
information, converts it into CMOS levels and routes it
to the Receiving Terminal Equipment via the
RPOS_(n), RNEG_(n) and RxClk_(n) output pins.
Each channel can deliver the recovered data and
clock information to the Receiving Terminal in either a
Single-Rail or Dual-Rail format.
3.6.1
Routing Dual-Rail Format Data to the
Receiving Terminal Equipment
Whenever a channel delivers Dual-Rail format to the
Terminal Equipment, it does so via the following sig-
nals.
RPOS_(n)
RNEG_(n)
RxClk_(n)
Figure 28 illustrates the typical interface for the trans-
mission of data in a Dual-Rail Format from the Re-
ceive Section of a channel to the Receiving Terminal
Equipment.
.
The manner that a given channel transmits Dual-Rail
data to the Receiving Terminal Equipment is de-
scribed below and illustrated in Figure 29. Each
COMMAND REGISTER CR3-(n)
D4
D3
D2
D1
D0
(SR/DR)_(n)
LOSMUT_(n)
RxOFF_(n)
RxClk_(n)INV
Reserved
X
1x
x
FIGURE 28. THE TYPICAL INTERFACE FOR THE TRANSMISSION OF DATA IN A DUAL-RAIL FORMAT,
FROM THE
RECEIVE SECTION OF THE XRT73L03B TO THE RECEIVING TERMINAL EQUIPMENT
Terminal
Equipment
(E3/DS3 or STS-1
Framer)
Exar E3/DS3/STS-1 LIU
Receive
Logic
Block
RxPOS
RxNEG
RxClk
RPOS
RNEG
RxClk
相关PDF资料
PDF描述
XRT73L04BIV-F IC LIU E3/DS3/STS-1 4CH 144LQFP
XRT73L06IB-F IC LIU E3/DS3/STS-1 6CH 217BGA
XRT73LC00AIV-F IC LIU STS1/DS3/E3 SGL 44TQFP
XRT73LC03AIV-F IC LIU E3/DS3/STS-1 3CH 120LQFP
XRT73LC04AIV-F IC LIU E3/DS3/STS-1 4CH 144LQFP
相关代理商/技术参数
参数描述
XRT73L03IV 制造商:EXAR 制造商全称:EXAR 功能描述:3 CHANNEL E3/DS3/STS-1 LINE INTERFCE UNIT
XRT73L03IVS 制造商:未知厂家 制造商全称:未知厂家 功能描述:Telecommunication IC
XRT73L04A 制造商:EXAR 制造商全称:EXAR 功能描述:4 CHANNEL DS3/E3/STS-1 LINE INTERFACE UNIT
XRT73L04AIV 制造商:EXAR 制造商全称:EXAR 功能描述:4 CHANNEL DS3/E3/STS-1 LINE INTERFACE UNIT
XRT73L04B 制造商:EXAR 制造商全称:EXAR 功能描述:4 CHANNEL DS3/E3/STS-1 LINE INTERFACE UNIT