YV09T50 50A DC-DC POL Converter
5V to 13.8V Input 0.6V to 3.63V Output
Data Sheet
where:
RTRIM = Required value of trim resistor in k
VOUT = Desired (trimmed) value of output voltage V
If the RTRIM is not used and the Sense+ and Sense-
pins are shorted to VOUT and GND respectively, the
output voltage of the POL converter will be 0.6V. No
capacitor is allowed between Trim+ and Trim- pins.
Note that the trim resistor tolerance directly affects
the output voltage accuracy. It is recommended to
use ±0.1% trim resistors to meet the output voltage
setpoint accuracy specified in p. 4.2.
Table 1. Trim Resistor Values
V0UT, V
Calculated
RTRIM, k
Standard Value of
0.1% Resistor, k
0.6
Open
1.0
3.0
3.01
1.2
2.0
1.5
1.333
1.33
1.8
1.0
2.0
0.857
0.856
2.5
0.631
0.634
3.3
0.444
0.442
3.63
0.396
0.397
6.3
ON/OFF (Pin 6)
The ON/OFF pin is used to turn the POL converter
ON or OFF remotely by a signal from a system
controller. For positive logic, the POL converter is
ON when the ON/OFF pin is at a logic high (2.4V
min) or left open. The POL converter is OFF when
the ON/OFF pin is at a logic low (1.2V max) or
connected to GND.
Figure 17. Circuit Configuration For ON/OFF Function
internal 50k pull-up to 5V supply.
It is
recommended to control the ON/OFF pin with an
open collector transistor or similar device.
6.4
Remote Sense (Pins 10 and 11)
The ON/OFF pin is referenced to ground and
typically has 50k input impedance.
It has an
s for the
of the POL
to the VOUT and GND pins
ote Sense Circu
uration
Becau
rrent,
rge traces on the end-user board are not required.
in order to
) is an open drain output,
A. The Power Good pin
voltage drops below a predetermined voltage. It will
The remote sense feature compensate
voltage drop between the output pins
converter and the load. The Sense- (Pin 10) and
Sense+ (Pin 11) pins should be connected at the
load or at the point where regulation is required
If remote sensing is not required, the Sense pins
must be connected
directly at the output of the POL converter.
Figure 18
Vin
. Rem
it Config
se the sense leads carry minimal cu
la
The voltage sense traces should be located close to
a ground plane to minimize system noise.
When using remote sense, the output voltage at the
converter can be increased by up to 0.5V
maintain the required voltage at the load. However,
the maximum output voltage measured directly
between the VOUT and GND pins shall not exceed
3.63V. In addition it is the user’s responsibility to
ensure the POL converter’s actual output power
always remains at or below the maximum allowable
output power obtained from the derating curves.
6.5
Protections
6.5.1
Power Good
Power Good pin (Pin 9
capable of sinking up to 4m
is high when the output voltage is within the
regulation band. The Power Good pin is at logic low
during
start-up,
undervoltage,
overvoltage,
or
overcurrent conditions, or when the POL converter is
disabled via the ON/OFF signal.
6.5.2
Input Undervoltage Lockout
The POL converter will shut down when the input
Vin
CONTROL
INPUT
VIN
GND
ON
VOUT
YV09T50
Power Good
TRIM+
SENSE+
Rload
GND
TRIM-
SENSE-
4,5
12,13
1,2,3
6
9
8
11
4,5
7
10
VIN
GND
ON/OFF
VOUT
Power Good
TRIM+
SENSE+
Rload
GND
TRIM-
SENSE-
Rw
4,
,5
7
5
12,13
1,2,3
11
YV09T50
6
9
8
4
10
ZD-02078 Rev 1.0
www.power-one.com
Page 10 of 13