参数资料
型号: 1.1001
元件分类: 保险丝
英文描述: Fuse
中文描述: 保险丝
文件页数: 16/65页
文件大小: 2586K
代理商: 1.1001
time-lag
=
T
super time-lag
=
TT
Example of fuse markings:
T200 mA / 250 V
UL listed and CSA certified fuses are not as easily identifiable
because neither any lettering nor color code is required on the
fuse itself.
11. Dimensions
Traditionally the dimensions have been 5 x 20mm for international
type fuses and 1/4 x 11/4" (6.3 x 32mm) for domestic, Northern
American fuses. Today however, IEC 5 x 20mm fuses with UL
recognition and CSA Component Acceptance are becoming
increasingly popular in North America, especially in applications
where saving space is a major concern.
It should also be pointed out that the 5 x 20mm fuse is available at
most over-the-counter distributors as well as radio supply shops in
North America.
IEC fuses of the 1/4 x 11/4" size should not be used in North
America. These fuses were designed for replacement use in
American made equipment located in Europe.
12. Interchangeability of IEC Fuses with UL Fuses and
Vice Versa
For general applications the rated current of the fuse to be
converted should be multiplied/divided by a factor 2 depending on
whether the fuse has to be converted from the use in a 250V
circuit to the use in a 125V circuit or vice versa. In this case,
however, the fuse normally doesn't provide anything more than
short current protection. For a more accurate correlation, the time
current characteristic curves of both the IEC and UL fuse must be
compared. As a rule of thumb, a factor of 2.4 to 2.6 can be used
to convert an IEC fuse (used in a 250V circuit) into a UL fuse
(used in a 125V circuit) with the corresponding characteristics
(e.g. a 1 A IEC fuse corresponds to a 2.5 A UL fuse).
7. Blowing Charts and Tables
This catalog differentiates between two types of blowing charts
and tables: IEC and UL/CSA. Proper understanding of these
differences is essential when one tries to match the fuse
characteristics to the circuit requirements.
a) Chart and Table for IEC fuses: This chart is an interval graph
showing a curve representing the minimum blowing times and
another curve representing maximum values for a set of current
ratings. The tables give the checkpoints or “gates” mandated by
IEC. Please note that only the gate values are tested by the
agencies. Values on the curve between two gates are
geometrically arrived at and are not guaranteed by the
manufacturer.
b) Chart and Table for UL/CSA listed fuses: The curves for this
graph represent average values, individually for each current
rating.
8. Fusing Integral l2t
The fusing integral is the thermal energy needed to melt the fuse-
element. The fusing integral l2t is used to determine:
- the blowing time for higher overcurrents
- the aging behavior of a fuse caused by in-rush currents.
The formula given below is only valid for blowing periods of less
than 10 ms.
l2t
t
=
= seconds + 20%
(overcurrent)2
To prevent aging caused by in-rush currents we recommend
staying within the following limits:
l2t of in-rush
less than 30% of fuse l2t for
(to be determined by user)
time delay fuses
less than 40% of fuse l2t for
normal blow fuses
The proper selection of a fuse requires that attention be given to
this subject. Often times a fuse problem can only be pinpointed
after a thorough study of this issue.
9. Power Dissipation
Power dissipation heats up the fuse and its surroundings.
Especially when selecting fuseholders, it is important to ensure
that, allowing for the ambient temperature, they are capable of
absorbing sufficient dissipated power. Please refer to the power
dissipation sections on the individual fuse pages when selecting a
fuse.
10. Specification of Characteristics
To quickly and easily classify the various fuse types by their time-
current characteristics, the following letter codes are stamped on
IEC, or other 5 x 20mm fuses.
Letter Code
super quick-acting
=
FF
quick-acting
=
F
medium time-lag
=
M
13. Quality Control
Details about Schurter’s strict quality control procedures are
available upon request.
Should you need fuses for non-standard applications, please
contact our Engineering Department.
Note: new fuse qualifications have been established for low-
voltage fuses; reference EIA/IS-722.
UL
I
A
n
I
A
n
IEC-(DIN)
22
20
18
16
14
12
10
8
6
4
2
0
02468
10
12
14
About Non-Resettable Fuses, continued
Schurter, Inc. Phone 707-778-6311 Fax 707-778-6401 E-mail info@schurterinc.com Website http://www.schurterinc.com
126
相关PDF资料
PDF描述
1.2501 Fuse
1-1337434-0 BNC STR B/HD JK RG58
1-1337436-0 BNC BULKHEAD JACK RG59
1-1337437-0 BNC ELBOW PLUG RG58
1-1337438-0 BNC ELBOW PLUG RG59
相关代理商/技术参数
参数描述
11-001.3-152FB 制造商:Aries Electronics Inc 功能描述:11 Position 152 Fusion Bonded Cable Jumpers
11-001.75-152FB 功能描述:多配对电缆 FUSION BONDED CABLE 11 CONDUCTORS RoHS:否 制造商:Belden Wire & Cable 线规 - 美国线规(AWG):18 对数:1 绞合:16 x 30 屏蔽:Shielded 长度:1000 ft 电压额定值:300 V 外壳材料:Polyvinyl Chloride (PVC) 绝缘材料:Polyethylene (PE) 类型:Audio, Control and Instrumentation 外壳颜色:Chrome
110010 功能描述:TEST LEAD PAIR R/A BANANA PLUG RoHS:否 类别:测试设备 >> 测试引线 - 香蕉,量表接口 系列:BU 标准包装:1 系列:6570 类型:插接线 配置:香蕉插头至短头鳄鱼夹 第一连接器:香蕉插头,单,屏蔽,直角 第二连接器:接线夹,隔离型,特大号 线缆长度:60.0"(1524.00mm) 所含物品:1 根引线,红 材料 - 绝缘体:硅树脂 堆叠方法:不可堆叠 线规:18 AWG 电压 - 额定:1000V(1kV) 额定电流:20A 额定值:CAT III 1000V,IEC 1010
110010000 功能描述:SKELETON BOT 4WD 制造商:seeed technology co., ltd 系列:Skeleton 零件状态:有效 配置:轮式 使用的 IC/零件:- 平台:Hercules 内容:完全装配 标准包装:1
11001010 制造商:RECOM POWER 功能描述:CONV DC/DC 3.5W 4.5-9VIN 09VOUT