参数资料
型号: 12217
厂商: NVE Corp/Sensor Products
文件页数: 140/145页
文件大小: 0K
描述: MAGNET 3.5MM DIA X 4MM THICK
标准包装: 10
系列: *
其它名称: Q7078272A
Appendix
Definitions and Conversion Factors
Definitions:
CSK or Sink: Current sinking output, also referred to as Open Collector output.
Differential: The field difference between the Operate Point and the Release Point.
Electrical Offset: The inherent imbalance of the bridge expressed in differential voltage output.
HBM: Human Body Model for ESD specifications.
Hysteresis: The maximum deviation in volts between the output with increasing field and the output
with decreasing field, where the applied field is unipolar (applied in either a positive or negative
direction, without crossing the zero field point), divided by Voltage Span. Expressed as a percentage.
Input Voltage Range: The voltage range that can be applied across the bridge.
IOL (Current Output Low): The output current in the low (logic 0) state (output stage switched on).
Max Output: A specification given in millivolts per applied voltage. This is the maximum output
voltage possible. This output condition is achieved when one set of resistors is in magnetic saturation
(have achieved the maximum resistance change possible) while the other pair are at zero applied
magnetic field.
Nonlinearity: The maximum deviation from a linear fit taken over the Field Range divided by the
Voltage Span. Expressed as a percentage.
Off-axis Characteristic: A specification that describes the variation in sensor output versus the angle
between the applied field direction and the sensitive axis of the GMR sensor with constant electrical
and magnetic inputs applied. Applicable to non-integrated bridge sensors. The output will vary as the
cosine of the angle rotated.
Operate Point: The field level which produces a logical change in state from “0” to “1” in NVE’s
digital magnetic field sensors ADXXX-XX.
Operating Frequency: Frequency range within which a sensor will produce a responsive output.
Output Leakage Current (Current Output High): The output current in the high (logic 1) state
(output stage switched off).
Output Saturation Voltage (Voltage Output Low): The output voltage in the low (logic 0) state
(output stage switched on).
RBP: Reverse Battery Protection.
Release Point: The field level which produces a logical change in state from “1” to “0” in NVE’s
digital magnetic field sensors ADXXX-XX.
Resistor Separation: This is the mean separation between the two pairs of resistors, in a Gradiometer
or Differential sensor.
Sensitivity: A measure of the output magnitude based on electrical and magnetic input conditions.
Expressed in millivolts of differential output per applied voltage per Oersted.
- 140 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
相关PDF资料
PDF描述
B512-2T-YDA MOD DIODE SCR 25A 240VAC .250"QC
HAL 200-S CURRENT TRANSDUCERS 200A 15V
B553-2 MOD DIODE SCR 25A 280VAC ISO QC
B511F-2 MOD DIODE SCR 25A 120VAC ISO QC
HAL 50-S CURRENT TRANSDUCERS 50A 15V
相关代理商/技术参数
参数描述
122170 制造商:Amphenol Connex 功能描述:TNC BLKHD CRMP JCK RG59-50--TF - Bag
1-22170-6 制造商:TE Connectivity 功能描述:PIN,COTTER - Bulk 制造商:TE CONNECTIVITY 功能描述:PIN,COTTER
1-22170-8 制造商:TE Connectivity 功能描述:PIN,COTTER - Bulk 制造商:TE CONNECTIVITY 功能描述:PIN,COTTER
1-2217206-0 功能描述:BLADE, SLUG 制造商:te connectivity amp connectors 系列:* 零件状态:有效 标准包装:1
1-2217206-1 功能描述:BLADE, SLUG 制造商:te connectivity amp connectors 系列:* 零件状态:有效 标准包装:1