参数资料
型号: 71M6531D-IMR/F
厂商: Maxim Integrated
文件页数: 89/121页
文件大小: 0K
描述: IC ENERGY METER 128KB 68-QFN
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 2,500
系列: *
FDS 6531/6532 005
Data Sheet 71M6531D/F-71M6532D/F
?
?
?
?
Select the values for SLOT0_SEL[3:0] = 0, SLOT1_SEL[3:0] = 1, SLOT2_SEL[3:0] = 2, SLOT3_SEL[3:0]
= 3
Select the values for SLOT0_ALTSEL[3:0] = 0x0A, SLOT1_ALTSEL[3:0] = 1, SLOT2_ALTSEL[3:0] =
0x0B, SLOT3_ALTSEL[3:0] = 3.
Set CHOP_E[1:0] = 00.
Initialize any MPU interrupts, such as CE_BUSY, XFER_BUSY, or a power failure detection interrupt.
When different CE codes are used, a different set of environment parameters needs to be established.
The exact values for these parameters are stated in the Application Notes and other documentation
accompanying the CE codes.
CE codes should only be used with environment parameters specified in this document or in the
applicable CE code description. Changing environment parameters at random will lead to unpre-
dictable results.
Typically, there are thirteen 32768 Hz cycles per ADC multiplexer frame (see Figure 19 ). This means that
the product of the number of cycles per frame and the number of conversions per frame must be 12 (allowing
for one settling cycle).
During operation, CHOP_E[1:0] = 00 enables the automatic chopping mode and forces an alternate
multiplexer sequence at regular intervals. This enables accurate temperature measurement.
4.3.5
CE Calculations
Table 56: CE EQU[2:0] Equations and Element Input Mapping
I0SQSUM
EQU[2:0]
Watt & VAR Formula
(WSUM/VARSUM)
W0SUM/
VAR0SUM
Element Input Mapping
W1SUM/
VAR1SUM
I1SQSUM
0
1
2
VA IA (1 element, 2W 1 φ )
with tamper detection
VA*(IA-IB)/2
(1 element, 3W 1 φ )
VA*IA + VB*IB
(2 element, 4W 2 φ )
VA*IA
VA*(IA-IB)/2
VA*IA
VA*IB
(VA * IB)/2
VB*IB
IA
IA-IB
IA
IB
IB
IB
4.3.6
CE Status and Control
The CESTATUS register provides information about the status of voltage and input AC signal frequency,
which are useful for generating early power fail warnings, e.g. to initiate necessary data storage. It contains
sag warning flags for VA and VB as well as F 0 , the derived clock operating at the fundamental input
frequency. CESTATUS represents the status flags for the preceding CE code pass (CE busy interrupt).
Sag alarms are not remembered from one code pass to the next. The CE Status word is refreshed at
every CE_BUSY interrupt. The significance of the bits in CESTATUS is shown in Table 57 .
CE Address
0x80
Name
CESTATUS
Description
See description of CESTATUS bits in Table 57 .
Since the CE_BUSY interrupt typically occurs at 2520.6 Hz, it is desirable to minimize the computation
required in the interrupt handler of the MPU. Rather than reading the CE status word at every CE_BUSY
interrupt and interpret the sag bits, it is recommended that the MPU activate the YPULSE output to generate
interrupts when a sag occurs (see the description of the CECONFIG register)
Rev 2
89
相关PDF资料
PDF描述
V48C28H75BG2 CONVERTER MOD DC/DC 28V 75W
ECA10DTKD CONN EDGECARD 20POS DIP .125 SLD
T95S334K035LZAL CAP TANT 0.33UF 35V 10% 1507
V48C28H75BG CONVERTER MOD DC/DC 28V 75W
SS8P4C-M3/87A DIODE SCHOTTKY 8A 40V SMPC
相关代理商/技术参数
参数描述
71M6531F 制造商:TERIDIAN 制造商全称:TERIDIAN 功能描述:Energy Meter IC
71M6531F-DB 功能描述:开发板和工具包 - 8051 71M6531F Demo Brd RoHS:否 制造商:Silicon Labs 产品:Development Kits 工具用于评估:C8051F960, Si7005 核心: 接口类型:USB 工作电源电压: