参数资料
型号: ADE7156ASTZF16-RL
厂商: Analog Devices Inc
文件页数: 132/152页
文件大小: 0K
描述: IC ENERGY METER 64-LQFP
产品变化通告: Product Discontinuance 27/Oct/2011
标准包装: 1,500
输入阻抗: *
测量误差: *
电压 - 高输入/输出: *
电压 - 低输入/输出: *
电流 - 电源: *
电源电压: *
测量仪表类型: *
工作温度: *
安装类型: 表面贴装
封装/外壳: 64-LQFP
供应商设备封装: 64-LQFP(10x10)
包装: 带卷 (TR)
ADE7116/ADE7156/ADE7166/ADE7169/ADE7566/ADE7569
SBAUDF is the fractional divider ratio required to achieve the
Rx
START
D0
D1
D2
D3
D4
D5
D6
D7
STOP
required baud rate. The appropriate value for SBAUDF can be
calculated with the following formula:
RI
?
SBAUDF = 64 × ?
? 16 × 2 DIV + SBTH × Baud Rate
? 1 ?
?
?
f CORE
?
?
FE
EXTEN = 1
Figure 108. UART Timing in Mode 1
Note that SBAUDF should be rounded to the nearest integer.
After the values for DIV and SBAUDF are calculated, the actual
baud rate can be calculated with the following formula:
Rx
START
D0
D1
D2
D3
D4
D5
D6
D7
D8
STOP
× ? ? 1 +
?
Actual Baud Rate =
16 × 2
f CORE
DIV + SBTH
?
SBAUDF ?
64 ?
RI
FE
EXTEN = 1
For example, to obtain a baud rate of 9600 bps while operating
at a core clock frequency of 4.096 MHz with the PLL CD bits
equal to 0,
Figure 109. UART Timing in Mode 2 and Mode 3
The 8052 standard UART does not provide break error detection.
However, for an 8-bit UART, a break error can be detected when
log ? ?
?
DIV + SBTH =
4,096,000 ?
? 16 × 9600 ?
log ( 2 )
= 4 . 74 = 4
the received character is 0, a null character, and when there is
no stop bit because the RB8 bit is low. Break error detection is
not possible for a 9-bit 8052 UART because the stop bit is not
recorded. The ADE7116/ADE7156/ADE7166/ADE7169/
SBAUDF = 64 × ? ? 1 ? = 42 . 67 = 0x2B
Note that the DIV result is rounded down.
4 , 096 , 000
? 16 × 2 3 × 9600 ?
Thus, the actual baud rate is 9570 bps, resulting in a 0.31% error.
UART ADDITIONAL FEATURES
Enhanced Error Checking
The extended UART provides frame error, break error, and
over-write error detection. Framing errors occur when a stop
bit is not present at the end of the frame. A missing stop bit
implies that the data in the frame may not have been received
properly. Break error detection indicates whether the Rx line
has been low for longer than a 9-bit frame. It indicates that the
data just received, a 0 or null character, is not valid because the
master has disconnected. Overwrite error detection indicates when
the received data has not been read fast enough and, as a result, a
byte of data has been lost.
The 8052 standard UART offers frame-error checking for an 8-bit
UART through the SM2 and RB8 bits. Setting the SM2 bit prevents
frames without a stop bit from being received. The stop bit is
latched into the RB8 bit in the serial communications control
SFR (SCON, Address 0x98). This bit can be examined to
ADE7566/ADE7569 enhanced break error detection is available
through the BE bit in the SBAUDT SFR.
The 8052 standard UART prevents overwrite errors by not
allowing a character to be received when the RI, receive interrupt
flag, is set. However, it does not indicate if a character has been
lost because the RI bit is set when the frame is received. The
enhanced UART overwrite error detection provides this infor-
mation. When the enhanced 8052 UART is enabled, a frame is
received regardless of the state of the RI flag. If RI = 1 when a
new byte is received, the byte in SCON is overwritten, and the
overwrite error flag is set. The overwrite error flag is cleared
when SBUF is read.
The extended UART is enabled by setting the EXTEN bit in the
Configuration SFR (CFG, Address 0xAF).
UART TxD Signal Modulation
There is an internal 38 kHz signal that can be OR’ed with the
UART transmit signal for use in remote control applications
(see the 38 kHz Modulation section).
One of the events that can wake the MCU from sleep mode is
activity on the Rx pin (see the 3.3 V Peripherals and Wake-Up
Events section).
determine if a valid frame was received. The 8052 does not,
however, provide frame error checking for a 9-bit UART. This
enhanced error checking functionality is available through the
frame error bit, FE, in the enhanced serial baud rate control SFR
(SBAUDT, Address 0x9E). The FE bit is set on framing errors
for both 8-bit and 9-bit UARTs.
Rev. B | Page 132 of 1 5 2
相关PDF资料
PDF描述
ADE7116ASTZF8-RL IC ENERGY METER 64-LQFP
ADE7116ASTZF8 IC ENERGY METER 64-LQFP
ADE5166ASTZF62-RL IC METER/8052/RTC/LCD DRV 64LQFP
ADE5166ASTZF62 IC METER/8052/RTC/LCD DRV 64LQFP
NCP699SN28T1G IC REG LDO 2.8V 240MA 5TSOP
相关代理商/技术参数
参数描述
ADE7156ASTZF8 功能描述:IC ENERGY METER 64-LQFP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7156ASTZF8-RL 功能描述:IC ENERGY METER 64-LQFP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7166 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC and LCD driver
ADE7166ACPZF16 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC, and LCD Driver
ADE7166ACPZF161 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC and LCD driver