ADMC200
REV. A
–4–
ORDERING GUIDE
Part
Number
Temperature
Range
Package
Description
Package
Option
ADMC200AP
–40
°
C to +85
°
C
68-Pin PLCC
P-68A
23
25
26
16
CLK
CS
A0–A3
RD
DATA
22
20
21
18
19
17
Figure 4. Read Cycle Timing Diagram
ABSOLUTE MAXIMUM RATINGS*
Supply Voltage (V
DD
) . . . . . . . . . . . . . . . . . . –0.3 V to +7.0 V
Digital Input Voltage . . . . . . . . . . . . . . . . . . . . . –0.3 V to V
DD
Analog Input Voltage . . . . . . . . . . . . . . . . . . . . . –0.3 V to V
DD
Analog Reference Input Voltage . . . . . . . . . . . . –0.3 V to V
DD
Digital Output Voltage Swing . . . . . . . . . . . . . . –0.3 V to V
DD
Analog Reference Output Swing . . . . . . . . . . . . –0.3 V to V
DD
Operating Temperature . . . . . . . . . . . . . . . . . –40
°
C to +85
°
C
Lead Temperature (Soldering, 10 sec) . . . . . . . . . . . . . +280
°
C
*Stresses greater than those listed above may cause permanent damage to the
device. These are stress ratings only, and functional operation of the device at these
or any other conditions greater than those indicated in the operational sections of
this specification is not implied. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability.
WARNING!
ESD SENSITIVE DEVICE
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the ADMC200 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.