参数资料
型号: AS1110 EB
厂商: ams
文件页数: 15/25页
文件大小: 0K
描述: BOARD EVAL AS1110
标准包装: 1
电流 - 输出 / 通道: 0.5 ~ 100 mA
输出及类型: 16,非隔离
输出电压: 0 ~ 15 V
特点: 过热保护,开路 LED,短路 LED,诊断
输入电压: 3 ~ 5.5 V
已供物品:
已用 IC / 零件: AS1110
AS1110
Datasheet - D e t a i l e d D e s c r i p t i o n
8.6.2
Detailed Open-LED Error Report
The detailed open-LED error report can be read out immediately after global error mode has been run. SDI must be 1 for the first device.
Figure 15. Detailed Open-LED Error Report Timing Diagram
OEN
Global Flag Readout
t TESTING
t H(L)
Detailed Error Report Readout
LD
t SU(ERROR)
t GSW(ERROR)
t P4
CLK
t GSW(ERROR)
t GSW(ERROR)
SDI
t SW(ERROR)
DBit15
DBit14 DBit13 DBit12 DBitn
DBit2
DBit1
DBit0
Don’t
Care
New Data Input
SDO
T Flag
O Flag
OBit15 OBit14 OBit13 OBit12 OBitn
OBit2
OBit1
OBit0
Don’t
Care
t P4
Open Error Report Output
t P1
For detailed timing information see Timing Diagrams on page 9 .
Detailed Open-LED Error Report Example
Consider a case where three AS1110s are cascaded in one chain. A 1 indicates a LED is on, a 0 indicates a LED is off, and an X indicates an
open LED. The open-LED test is only applied to LEDs that are turned on. This test is used with a test pattern where all LEDs are on at test time.
IC1:[1111111111111111] IC2:[111XX11111111X11] IC3:[1111111111111111]
IC2 has three open LEDs switched on due to input. 3*16 clock cycles are needed to write the entire error code out. The detailed error report
would look like this:
Input Data: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
LED Status: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Failure Code: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1111111111111111
1 1 1 XX1 1 1 1 1 1 1 1 X1 1
1110011111111011
1111111111111111
1111111111111111
1111111111111111
Comparing this report with the input data indicates that IC2 is the device with two open LEDs at position 4 and 5 and one open LED at position
14. For such a test it is recommended to enter low-current diagnostic mode first (see Low-Current Diagnostic Mode on page 15) to reduce screen
flickering.
This test can be used also on-the-fly without using an all 1s test pattern (see Figure 19 on page 17) .
Note: In an actual report there are no spaces in the output. LEDs turned off during test time cannot be tested and will show a logic 1 in the
detailed error report.
Revision 1.6
14 - 24
相关PDF资料
PDF描述
AS1112 EB BOARD EVAL AS1112
AS1115 DB-YELLOW BOARD DEMO AS1115 YELLOW
AS1116 DB-YELLOW BOARD DEMO AS1116 YELLOW
AS3691A EB BOARD EVAL AS3691A
AS5030 DB BOARD DEMO AS5030
相关代理商/技术参数
参数描述
AS1110-QF_EK_ST 功能描述:AS1110 16, Non-Isolated Output LED Driver Evaluation Board 制造商:ams 系列:- 零件状态:有效 电流 - 输出/通道:100mA 输出和类型:16,非隔离 电压 - 输出:15V 特性:过热保护,开路 LED,短路 LED,诊断 电压 - 输入:3 V ~ 5.5 V 所含物品:板 使用的 IC/零件:AS1110 标准包装:1
AS11110 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog IC
AS11110-XXX-I-A1-D 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog Filter
AS11110-XXX-I-A1-S 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog Filter
AS11110-XXX-I-A2-D 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog Filter