6.5 MODULE 5 - S ERIAL C OMMUNICATIONS P ARAMETERS ( 5-SEriAL )
5-SEriAL
SEL
PARAMETER MENU
Pro
bAUd
Baud Rate
dAtA
Data Bit
PAritY
Parity Bit
Addr
Meter
Abbr
Abbreviated
Prnt OPt
Print
COPY
Copy Program
Address
Printing
Options
Settings
Module 5 is the programming module for the Serial Communications
Parameters. These parameters are used to match the serial settings of the
CUB5T with those of the host computer or other serial device. The Serial Setup
ABBREVIATED PRINTING
Parameters are only accessible when an optional RS232 or RS485 serial
communications module is installed in the meter.
This section replaces the bulletin shipped with the RS232 and RS485 serial
?
Abbr
?
NO
NO
YES
communications plug-in cards. Discard the separate bulletin when using those
serial plug-in cards with the CUB5T.
BAUD RATE
This parameter determines the formatting of data transmitted from the meter
in response to a Transmit Value command or a Block Print Request. Select NO
for a full print transmission, consisting of the meter address, mnemonics, and
parameter data. Select YES for abbreviated print transmissions, consisting of the
parameter data only. This setting is applied to all the parameters selected in the
PRINT OPTIONS. (Note: If the meter address is 0, the address will not be sent
during a full transmission.)
?
bAUd
?
9600
300
600
1200
2400
4800
9600
19200
38400
Set the baud rate to match that of other serial communications equipment.
Normally, the baud rate is set to the highest value that all of the serial
communications equipment is capable of transmitting and receiving.
Prnt OPt ?
? NO
PRINT OPTIONS
NO YES
This parameter selects the meter values transmitted in response to a Print
DATA BIT
Request. A print request is also referred to as a block print because more than
?
dAtA
?
7-bit
7-bit
8-bit
one parameter can be sent to a printer or computer as a block.
Selecting YES displays a sublist for choosing the meter parameters to appear
in the print block. All active parameters entered as YES in the sublist will be
transmitted during a block print. Parameters entered as NO will not be sent.
Select either 7- or 8-bit data word length. Set the word length to match the
other serial communications equipment on the serial link.
The “Print All” ( Prnt ALL ) option selects all meter values for transmitting
( YES ), without having to individually select each parameter in the sublist.
Note: Inactive parameters will not be sent regardless of the print option
setting. For example, the Cycle Counter and Cycle Counter Start values will
only be sent when the Cycle Counter is enabled. If disabled, these parameters
PAritY
?
?
Odd
NO
PARITY BIT
Odd
EVEN
are inactive and will not be transmitted. Likewise, the Setpoint parameters will
not be sent unless an optional setpoint card is installed in the meter.
FACTORY
DISPLAY DESCRIPTION MNEMONIC
SETTING
This parameter only appears when the Data Bit parameter is set to a 7-bit
data word length. Set the parity bit to match that of the other serial equipment
on the serial link. The meter ignores parity when receiving data and sets the
parity bit for outgoing data. If parity is set to NO , an additional stop bit is used
to force the frame size to 10 bits.
t-VALUE
C-VALUE
t-Strt
t-StOP
Cnt Strt
SPt ON
Timer
Cycle Counter
Timer Start
Timer Stop
Counter Start
Setpoint ON
YES
NO
NO
NO
NO
NO
TMR
CNT
TST
TSP
CST
SPT
?
Addr
?
00
METER ADDRESS
0 to 99
SPt OFF
SPt tOUt
Setpoint OFF
Setpoint Time-out
NO
NO
SOF
STO
Enter the serial node address. With a single unit, an address is not needed
and a value of zero can be used (RS232 applications). Otherwise, with multiple
bussed units, a unique address number must be assigned to each meter. The
node address applies specifically to RS485 applications.
11
相关PDF资料
PDF描述
CUB7P200 HSPEED LOGIC INPUT CNTR POS
CUB7T000 TIMER LCD PROGRAM 8 DIGIT
CUB7W020 COUNTER 8-DIGIT RED BKLT VOLT-IN
D-659-0001 TOOL REMOVAL MTC CONN WAFER
D7-1 DIE, .041 HOLE DIA
相关代理商/技术参数
参数描述
CUB5TCB0 功能描述:METER PANEL LCD THERMOCOUPLE RED RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:CUB5 标准包装:12 系列:* 其它名称:Q7072030
CUB5TCR0 功能描述:THERMO METER REFLECTIVE RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:* 标准包装:12 系列:* 其它名称:Q7072030
CUB5TR00 制造商:Red Lion Controls 功能描述:PRESET TIMR & CYCLE COUNTR W/REFL DSPLY 制造商:Red Lion Controls 功能描述:TIMER, ELECTRONIC , 8DIGIT, 9V TO 28V; Supply Voltage Range:9V DC to 28V DC; Panel Cutout Height:39.1mm; Panel Cutout Width:74.9mm; Time Range:- ;RoHS Compliant: Yes
CUB5USB0 功能描述:USB OPTION CARD RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:* 标准包装:12 系列:* 其它名称:Q7072030
CUB5VB00 功能描述:DC VOLTMETER RED/GREEN BKLT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:* 标准包装:12 系列:* 其它名称:Q7072030