DS21FT44/DS21FF44
72 of 117
register. The read result should be logically AND’ed with the mask byte that was just written and this
value should be written back into the same register to insure that bit does indeed clear. This second write
step is necessary because the alarms and events in the status registers occur asynchronously in respect to
their access by the parallel port. This write-read-write (for polled-driven access) or write–read (for
interrupt driven access) scheme allows an external microcontroller or microprocessor to individually poll
certain bits without disturbing the other bits in the register. This operation is key in controlling the
DS21Q44 with higher order software languages.
Like the SR1 and SR2 status registers, the HSR register has the unique ability to initiate a hardware
interrupt by the INT* output pin. Each of the events in the HSR can be either masked or unmasked from
the interrupt pin by the HDLC Interrupt Mask Register (HIMR). Interrupts will force the INT* pin low
when the event occurs. The INT* pin will be allowed to return high (if no other interrupts are present)
when the user reads the event bit that caused the interrupt to occur.
19.3. BASIC OPERATION DETAILS
As a basic guideline for interpreting and sending HDLC messages, the following sequences can be
applied:
Receive a HDLC Message
1) Enable RPS interrupts.
2) Wait for interrupt to occur.
3) Disable RPS interrupt and enable either RPE, RNE, or RHALF interrupt.
4) Read RHIR to obtain REMPTY status.
a) If REMPTY = 0, then record OBYTE, CBYTE, and POK bits and then read the FIFO
a1) If CBYTE = 0 then skip to Step 5
a2) If CBYTE = 1 then skip to Step 7
b) If REMPTY = 1, then skip to Step 6
5) Repeat Step 4.
6) Wait for interrupt, skip to Step 4.
7) If POK = 0, then discard whole packet, if POK = 1, accept the packet.
8) Disable RPE, RNE, or RHALF interrupt, enable RPS interrupt and return to Step 1.
Transmit a HDLC Message
1) Make sure HDLC controller is done sending any previous messages and is current sending flags by
checking that the FIFO is empty by reading the TEMPTY status bit in the THIR register.
2) Enable either the THALF or TNF interrupt.
3) Read THIR to obtain TFULL status.
a) If TFULL = 0, then write a byte into the FIFO and skip to next step (special case occurs
when the last byte is to be written, in this case set TEOM = 1 before writing the byte and
then skip to Step 6)
b) If TFULL = 1, then skip to Step 5
4) Repeat Step 3.
5) Wait for interrupt, skip to Step 3.
6) Disable THALF or TNF interrupt and enable TMEND interrupt.
7) Wait for an interrupt, then read TUDR status bit to make sure packet was transmitted correctly.
相关PDF资料
PDF描述
DS21Q352B IC TXRX QUAD T1/E1 3.3V 256-BGA
DS21Q41BT IC FRAMER T1 QUAD 128-TQFP
DS21Q42T+ IC FRAMER ENHANCED T1 4X 128TQFP
DS21Q43-ATN IC FRAMER E1 QUAD 5V 128-TQFP
DS21Q44T+ IC FRAMER ENHANCED E1 4X 128TQFP
相关代理商/技术参数
参数描述
DS21FT44N+ 功能描述:网络控制器与处理器 IC 4x4 16/4x3 12 Chnl E1/E1 Framer RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
DS21Q348 功能描述:网络控制器与处理器 IC RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
DS21Q348B 功能描述:网络控制器与处理器 IC RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
DS21Q348DK 功能描述:网络开发工具 RoHS:否 制造商:Rabbit Semiconductor 产品:Development Kits 类型:Ethernet to Wi-Fi Bridges 工具用于评估:RCM6600W 数据速率:20 Mbps, 40 Mbps 接口类型:802.11 b/g, Ethernet 工作电源电压:3.3 V
DS21Q348N 功能描述:网络控制器与处理器 IC RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray