参数资料
型号: ER3-512
厂商: TechTools
文件页数: 9/24页
文件大小: 0K
描述: EMULATOR EPROM ECONOROM III 512K
标准包装: 1
系列: EconoROM™ III
类型: 存储器
适用于相关产品: EPROMs
所含物品: ER3 EconoROM III 仿真器,线缆(菊花链、LPT 和目标)等
配用: CBL08-25-ND - 25 FT DOWNLOAD CABLE UPGRADE
C32D-6-ND - 6" TARGET CABLE IDC TO 32PIN DIP
C28D-6-ND - 6" TARGET CABLE IDC TO 28PIN DIP
PS-RT1-ND - EXTERNAL PWR SUPPLY
其它名称: ER3512
Apply Power
The emulator can be powered from the target or via an optional external power supply. If your target
operates at 5Volts and can supply the extra emulator current (100ma typical/200ma max) to the memory
socket, then you can use target power. If your target operates at less than 5V or is incapable of supply the
extra emulator current, then you must use an external power supply. External power supplies are available
from TechTools or your local dealer. The external supply must provide a regulated 5VDC at 300ma or
greater.
The emulator status LED operates differently based on whether you are using target power or external
power.
Using Target Power
Turn on your target power supply. The emulator status LED should glow a STEADY GREEN. If not, refer
to the troubleshooting tips below to correct the problem before continuing.
LED does not turn on:
Immediately turn off target power and correct the
problem before reapplying power!
Your target does not have enough power to operate the emulator or power is not reaching the emulator.
- Verify all target cable connections
- Verify the target cable is plugged in correctly (pin 1 orientation)
- Verify that any adapters you might be using are the correct pin-outs.
- Once you are SURE the emulator is not being subjected to reverse voltage, verify the target
provides at least 4.5V to the memory socket WHILE THE EMULATOR IS PLUGGED IN.
Connect an external power supply to the emulator if necessary.
LED GLOWS RED:
Your target does not have enough power to operate the emulator or is supplying less than 4.5V.
- Verify all target cable connections
- Verify the target cable is plugged in correctly (pin 1 orientation)
- Verify that any adapters you might be using are the correct pin-outs.
- Verify the target provides at least 4.5V to the memory socket WHILE THE EMULATOR IS
PLUGGED IN. Connect an external power supply to the emulator if necessary.
LED Flashes GREEN:
You have enough power, but you failed to connect the reset line properly. When the emulator is first
powered up, it asserts RESET to keep the target from running until it has received a download. The
flashing GREEN LED indicates target activity.
- Verify the RESET line is connected
- Verify your selection of the RESET attachment point
- Verify your selection of RESET polarity.
Econo ROM III User’s Manual
5
Copyright ? 2000, TechTools
相关PDF资料
PDF描述
LXD40-0700SW POWER SUPPLY LED 40W 700MA DIM
MAX5062CASA+T IC MOSFET DRIVER 8-SOIC
VE-B2T-CW-F2 CONVERTER MOD DC/DC 6.5V 100W
MAX628ESA+ IC DRIVER MOSFET DUAL 8-SOIC
LQH32MN391J23L INDUCTOR 390UH 5% 50MA 1210
相关代理商/技术参数
参数描述
ER35-3C90 制造商:FERROXCUBE 制造商全称:Ferroxcube International Holding B.V. 功能描述:ER cores
ER35-3C94 制造商:FERROXCUBE 制造商全称:Ferroxcube International Holding B.V. 功能描述:ER cores
ER35BEIGE 制造商:IMO Precision Controls Ltd 功能描述:TERMINAL BLOCK FEED THRU 35MM
ER35BEIGE 制造商:IMO Precision Controls Ltd 功能描述:TERMINAL FEED THROUGH 35MM
ER35PBEIGE 制造商:IMO Precision Controls Ltd 功能描述:TERMINAL BLOCK DIN SCREW 35MM 制造商:IMO Precision Controls Ltd 功能描述:TERMINAL BLOCK, DIN, SCREW, 35MM 制造商:IMO 功能描述:TERMINAL BLOCK, DIN, SCREW, 35MM, Connector Type:Terminal Block, DIN Rail, Serie 制造商:IMO Precision Controls Ltd 功能描述:TERMINAL BLOCK, DIN, SCREW, 35MM, Connector Type:Terminal Block, DIN Rail, Series:ER, Connector Mounting:DIN Rail, Pitch Spacing:16mm, No. of Contacts:2, Wire Size AWG Max:0AWG, Contact Plating:Tin, Contact Material:Brass, SVHC:No , RoHS Compliant: Yes