参数资料
型号: FK1501-7RD0TB2
厂商: POWER-ONE INC
元件分类: 电源模块
英文描述: 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
封装: METAL, CASE K02, MODULE
文件页数: 22/31页
文件大小: 1251K
代理商: FK1501-7RD0TB2
Rugged Environment
DC-DC Converters >100 Watt
K Series
Edition 4/4.99
29/31
MELCHER
The Power Partners.
V output (V0, V2, V3):
Connector pin V is internally connected to the open collec-
tor of a NPN transistor. The emitter is connected to the
negative potential of output 1.
UV
≤ 0.6 V (logic low) corre-
sponds to a monitored voltage level (
Ui and/or Uo1)
<U
t.
The current
IV through the open collector should not exceed
50 mA. The NPN output is not protected against external
overvoltages.
UV should not exceed 60 V.
Ui, Uo1 status
V output,
UV
Ui or Uo1 < Ut
low, L,
UV ≤ 0.6 V at IV = 50 mA
Ui and Uo1 > Ut + Uh
high, H,
IV ≤ 25 A at UV = 5.1 V
Fig. 34
Output configuration of options V0, V2 and V3
Vo1+
Vo1–
V
UV
IV
Rp
Input
11009
Formula for the external input capacitor:
2
Po (th + 0.3 ms) 100
Ci ext = –––––––––––––––––––––– – Ci min
h (Uti 2 – Ui min2)
where as:
Ci min = internal input capacitance [mF]
Ci ext = external input capacitance [mF]
Po
= output power [W]
h
= efficiency [%]
th
= hold-up time [ms]
Ui min = minimum input voltage [V] 1
Uti
= threshold level [V]
1 Min. input voltage according to Electrical Input Data. For output
voltages
Uo > Uo nom, the minimum input voltage increases pro-
portionally to
Uo/Uo nom.
Remarks:
Option V2 and V3 can be adjusted by potentiometer to a
threshold level between
Ui min and Ui max. A decoupling di-
ode should be connected in series with the input of AK...FK
converters to avoid the input capacitance discharging
through other loads connected to the same source voltage.
V ACFAIL signal (VME)
Available for units with
Uo1 = 5.1 V.
This option defines an undervoltage monitoring circuit for
the input or input and main output voltage (
Uo1 nom = 5.1 V
only) equivalent to option D and generates an ACFAIL sig-
nal (V signal) which conforms to the VME standard.
The low state level of the ACFAIL signal is specified at a
sink current of
IV ≤ 48 mA to UV ≤ 0.6 V (open-collector out-
put of a NPN transistor). The pull-up resistor feeding the
open-collector output should be placed on the VME back
plane.
After the ACFAIL signal has gone low, the VME standard
requires a hold-up time
th of at least 4 ms before the 5.1 V
output drops to 4.875 V when the output is fully loaded.
This hold-up time
th is provided by the internal input capaci-
tance. Consequently the working input voltage and the
threshold level
Uti should be adequately above the mini-
mum input voltage
Ui min of the converter so that enough
energy is remaining in the input capacitance. If the input
voltage is below the required level, an external hold-up ca-
pacitor (
Ci ext) should be added.
Formula for threshold level for desired value of
th:
2
Po (th + 0.3 ms) 100
Uti =
––––––––––––––––––––– +
Ui min2
Ci min h
Table 20: Undervoltage monitor functions
V output
Monitoring
Minimum adjustment range
Typical hysteresis
Uh [% of Ut]
(VME compatible)
of threshold level
Ut
for
Ut min…Ut max
Ui
Uo1
Uti
Uto
Uhi
Uho
V2
yes
no
Ui min...Ui max 1
3.4...0.4
V3
yes
Ui min...Ui max 1
0.95...0.985
Uo1 2
3.4...0.4
"0"
V0
yes
no
Ui min...Ui max 3 4
3.4...0.4
yes
Ui min...Ui max 3 4
0.95...0.985
Uo1 2
3.4...0.4
"0"
1 Threshold level adjustable by potentiometer. 2 Fixed value between 95% and 98.5% of Uo1 (tracking). 3 Adjusted at Io nom.
4 Fixed value, resistor-adjusted (
±2% at 25°C) acc. to customer's specifications; individual type number is determined by Melcher.
voltage(s) exceed(s)
Ut + Uh. The threshold level Uti is ei-
ther adjustable by potentiometer, accessible through a hole
in the front cover, or adjusted during manufacture to a de-
termined customer specified value.
Versions V0, V2 and V3 are available as shown below.
Option V operates independently of the built-in input under-
voltage lock-out circuit. A logic "low" signal is generated at
pin 20 as soon as one of the monitored voltages drops be-
low the preselected threshold level
Ut. The return for this
signal is Vo1–. The V output recovers when the monitored
Table 19: Available internal input capacitance and factory potentiometer setting of Uti with resulting hold-up time
Types
AK
BK
FK
CK
DK
EK
Unit
Ci min
0.83
0.3
1.2
0.66
0.26
0.21
mF
Ut i
9.5
19.5
39
61
97
V DC
th
0.1
3.4
1.1
2.7
ms
相关PDF资料
PDF描述
FK1501-9PD0B2 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
FK1501-9PD8TB2 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
FK1501-9RDDT 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
FK1601-9PD8B2 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
FK1601-9RD8TB2 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
FK1501-9ER 制造商:Power-One 功能描述:DCDC - Bulk
F-K15-1 制造商:Cosel Usa Inc 功能描述:Optional Accessories, OP Series
F-K15-2 制造商:Cosel Usa Inc 功能描述:Optional Accessories, OP Series
FK15M 功能描述:TAPERED END PENETRATION PROBE RoHS:是 类别:测试设备 >> 测试引线 - 热电偶,温度探头 系列:FK 标准包装:1 系列:6543 类型:J 型热电偶 使用:液体,半固体 尖端 - 类型:防浸渍 / 穿透式,圆头 插头类型:超微型(热电偶插头) 探针温度范围:-40 ~ 2000°F(-40 ~ 1093°C) 线缆长度:- 线缆绝缘:- 插头颜色:黑 探针长度:12.000"(304.80mm) 探针材料:-
FK15S BLK 制造商:SCHUTZINGER 功能描述:4MM PLG STACK BLACK