参数资料
型号: HIP6017BCB
厂商: INTERSIL CORP
元件分类: 稳压器
英文描述: FPGA - 100000 SYSTEM GATE 2.5 VOLT - NOT RECOMMENDED for NEW DESIGN
中文描述: SWITCHING CONTROLLER, 215 kHz SWITCHING FREQ-MAX, PDSO28
封装: PLASTIC, MS-013AE, SOIC-28
文件页数: 8/16页
文件大小: 139K
代理商: HIP6017BCB
8
soft-start interval (T4 in Figure 6). At start-up, this allows
V
OUT2
and V
OUT3
to slew up without generating a fault.
Cycling the bias input voltage (+12V
IN
on the VCC pin) off
then on resets the counter and the fault latch.
Over-Voltage Protection
During operation, a short on the upper PWM MOSFET (Q1)
causes V
OUT1
to increase. When the output exceeds the
over-voltage threshold of 115% (typical) of DACOUT, the
over-voltage comparator trips to set the fault latch and turns Q2
on as required in order to regulate V
OUT1
to 1.15 x DACOUT.
This blows the input fuse and reduces V
OUT1
. The fault latch
raises the FAULT/RT pin close to VCC potential.
A separate over-voltage circuit provides protection during
the initial application of power. For voltages on the VCC pin
below the power-on reset (and above ~4V), V
OUT1
is
monitored for voltages exceeding 1.26V. Should VSEN1
exceed this level, the lower MOSFET (Q2) is driven on as
needed to regulate V
OUT1
to 1.26V.
Over-Current Protection
All outputs are protected against excessive over-currents.
The PWM controller uses the upper MOSFET’s on-
resistance, r
DS(ON)
to monitor the current for protection
against shorted outputs. The linear regulator monitors the
current of the integrated power device and signals an over-
current condition for currents in excess of 230mA.
Additionally, both the linear regulator and the linear controller
monitor FB2 and FB3 for under-voltage to protect against
excessive currents.
Figures 8 and 9 illustrate the over-current protection with
an overload on OUT1. The overload is applied at T0 and
the current increases through the output inductor (L
OUT1
).
At time T1, the OVER-CURRENT1 comparator trips when
the voltage across Q1 (I
D
x r
DS(ON)
) exceeds the level
programmed by R
OCSET
. This inhibits all outputs,
discharges the soft-start capacitor (C
SS
) with a 11mA
current sink, and increments the counter. C
SS
recharges at
T2 and initiates a soft-start cycle with the error amplifiers
clamped by soft-start. With OUT1 still overloaded, the
inductor current increases to trip the over-current
comparator. Again, this inhibits all outputs, but the soft-start
voltage continues increasing to 4V before discharging. The
counter increments to 2. The soft-start cycle repeats at T3
and trips the over-current comparator. The SS pin voltage
increases to 4V at T4 and the counter increments to 3. This
sets the fault latch to disable the converter. The fault is
reported on the FAULT/RT pin.
The linear regulator operates in the same way as PWM1 to
over-current faults. Additionally, the linear regulator and
linear controller monitor the feedback pins for an under-
voltage. Should excessive currents cause FB2 or FB3 to fall
below the linear under-voltage threshold, the LUV signal
sets the over-current latch if C
SS
isfully charged. Blanking the
LUV signal during the C
SS
charge interval allows the linear
outputs to build above the under-voltage threshold during
normal start-up. Cycling the bias input power off then on
resets the counter and the fault latch.
Resistor R
OCSET1
programs the over-current trip level for the
PWM converter. As shown in Figure 9, the internal 200
μ
A
current sink develops a voltage across R
OCSET
(V
SET
) that is
referenced to V
IN
. The DRIVE signal enables the over-current
comparator (OVER-CURRENT1). When the voltage across
the upper MOSFET (V
DS(ON)
) exceeds V
SET
, the over-
current comparator trips to set the over-current latch. Both
V
SET
and V
DS
are referenced to V
IN
and a small capacitor
across R
OCSET
helps V
OCSET
track the variations of V
IN
due
to MOSFET switching. The over-current function will trip at a
peak inductor current (I
PEAK
) determined by:
I
DS ON
)
The OC trip point varies with MOSFET’s temperature. To
avoid over-current tripping in the normal operating load
FAULT
LATCH
S
R
Q
POR
COUNTER
OC1
OV
LUV
+
-
+
-
0.15V
4V
SS
VCC
FAULT
R
FIGURE 7. FAULT LOGIC - SIMPLIFIED SCHEMATIC
UP
OVER
CURRENT
LATCH
INHIBIT
S
R
Q
S
S
0A
0V
2V
4V
FIGURE 8. OVER-CURRENT OPERATION
TIME
T1
T2
T3
T0
T4
F
0V
10V
COUNT
= 1
COUNT
= 2
COUNT
= 3
OVERLOAD
APPLIED
FAULT
REPORTED
I
PEAK
=
R
×
---------------------------------------------------
HIP6017B
相关PDF资料
PDF描述
HIP6018B 100,000 System Gate FPGA - NOT RECOMMENDED for NEW DESIGN
HIP6018BCB FPGA - 100000 SYSTEM GATE 2.5 VOLT - NOT RECOMMENDED for NEW DESIGN
HIP6019 FPGA - 100000 SYSTEM GATE 2.5 VOLT - NOT RECOMMENDED for NEW DESIGN
HIP6019CB Advanced Dual PWM and Dual Linear Power Control
HIP6019EVAL1 Advanced Dual PWM and Dual Linear Power Control
相关代理商/技术参数
参数描述
HIP6017BCB WAF 制造商:Harris Corporation 功能描述:
HIP6017BCB-T 制造商:Rochester Electronics LLC 功能描述:- Tape and Reel
HIP6017CB 制造商:Rochester Electronics LLC 功能描述:- Bulk
HIP6017CB WAF 制造商:Harris Corporation 功能描述:
HIP6017CB-T 制造商:Rochester Electronics LLC 功能描述:- Bulk