参数资料
型号: IR3009
厂商: International Rectifier
英文描述: 3 PHASE OPTERON, ATHLON, OR VR10.X CONTROL IC
中文描述: 3相皓龙,速龙,或控制IC的VR10.X
文件页数: 12/39页
文件大小: 693K
代理商: IR3009
IR3093
Page 12 of 39
07/15/04
Figure 3
– 3 Phase Oscillator and PWM Waveforms
The RSFF is reset dominant allowing both phases to go to zero duty cycle within a few tens of nanoseconds in
response to a load step decrease. Phases can overlap and go to 100% duty cycle in response to a load step increase
with turn-on gated by the clock pulses. An Error Amplifier output voltage greater than the common mode input range of
the PWM comparator results in 100% duty cycle regardless of the voltage of the PWM ramp. This arrangement
guarantees the Error Amplifier is always in control and can demand 0 to 100% duty cycle as required. It also favors
response to a load step decrease which is appropriate given the low output to input voltage ratio of most systems. The
inductor current will increase much more rapidly than decrease in response to load transients.
This control method is designed to provide “single cycle transient response” where the inductor current changes in
response to load transients within a single switching cycle maximizing the effectiveness of the power train and
minimizing the output capacitor requirements.
Body Braking
TM
In a conventional synchronous buck converter, the minimum time required to reduce the current in the inductor in
response to a load step decrease is;
T
SLEW
= [L x (I
MAX
- I
MIN
)] / Vout
The slew rate of the inductor current can be significantly increased by turning off the synchronous rectifier in response
to a load step decrease. The switch node voltage is then forced to decrease until conduction of the synchronous
rectifier’s body diode occurs. This increases the voltage across the inductor from Vout to Vout + V
BODY DIODE
. The
minimum time required to reduce the current in the inductor in response to a load transient decrease is now;
T
SLEW
= [L x (I
MAX
- I
MIN
)] / (Vout + V
BODY DIODE
)
CLK1
CLK3
50% INTERNAL OSCILLATOR RAMP
RAMP1 SLOPE = 50mV / % DC
0.6V
FIXED RAMP1
EAOUT
RAMP3
RAMP3 MIN DUTY
CYCLE ADJUST
RAMP3 MAX DUTY
CYCLE ADJUST
THE SHARE ADJUST ERROR AMPLIFIER CAN
CHANGE THE PULSE WIDTH OF RAMPS 2 & 3 FROM
0.5 x RAMP1 TO 2.0 X RAMP1 TO FORCE
CURRENT SHARING.
CLK2
RAMP2
相关PDF资料
PDF描述
IR3093M 3 PHASE OPTERON, ATHLON, OR VR10.X CONTROL IC
IR3093MTR 3 PHASE OPTERON, ATHLON, OR VR10.X CONTROL IC
IR3080 XPHASE VRD10 CONTROL IC WITH VCCVID & OVERTEMP DETECT
IR3080MTR XPHASE VRD10 CONTROL IC WITH VCCVID & OVERTEMP DETECT
IR3080M XPHASE VRD10 CONTROL IC WITH VCCVID & OVERTEMP DETECT
相关代理商/技术参数
参数描述
IR301 制造商:Extech 功能描述:IR Plus Stem Thermometer 制造商:Extech 功能描述:IR + STEM THERMOMETER
IR3020-02BG 制造商:SMC Corporation of America 功能描述:Precision Regulator+Gauge, Bracket,R1/4
IR3020-F03 制造商:SMC 功能描述:Precision Regulator 3/8, 0.01 to 0.8MPa
IR3020-F04 制造商:SMC 功能描述:Precision Regulator 1/2, 0.01 to 0.8MPa
IR3080 制造商:IRF 制造商全称:International Rectifier 功能描述:XPHASE VRD10 CONTROL IC WITH VCCVID & OVERTEMP DETECT