163
(23)
TCLAV
Address Valid Delay
10
110
10
60
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(24)
TCLAX
Address Hold Time
10
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(25)
TCLAZ
Address Float Delay
TCLAX
80
TCLAX
50
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(26)
TCHSZ
Status Float Delay
80
50
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(27)
TSVLH
Status Valid to ALE High (Note 10)
20
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(28)
TSVMCH
Status Valid to MCE High (Note 10)
30
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(29)
TCLLH
CLK low to ALE Valid (Note 10)
20
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(30)
TCLMCH
CLK low to MCE High (Note 10)
25
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(31)
TCHLL
ALE Inactive Delay (Note 10)
4
18
4
18
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(32)
TCLMCL
MCE Inactive Delay (Note 10)
15
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(33)
TCLDV
Data Valid Delay
10
110
10
60
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
(34)
TCLDX2
Data Hold Time
10
ns
CL = 100pF for All
80C86
Outputs
(In
Addition
to
80C86
Self Load)
AC Electrical Specifications
VCC = 5.0V ±10%
TA = 0
oC to +70oC (C80C86, C80C86-2)
VCC = 5.0V ±10%; TA = -40
oC to +85oC (I80C86, I80C86-2)
VCC = 5.0V ±10%; TA = -55
oC to +125oC (M80C86)
VCC = 5.0V ±5%;
TA = -55
oC to +125oC (M80C86-2) (Continued)
MAX MODE SYSTEM (USING 82C88 BUS CONTROLLER)
TIMING REQUIREMENTS
80C86
80C86-2
UNITS
TEST CONDITIONS
SYMBOL
PARAMETER
MIN
MAX
MIN
MAX
80C86