APPLICATIONS INFORMATION
MODES OF OPERATION
The LTC6802-1 has three modes of operation: standby,
measure and monitor. Standby mode is a power saving state
where all circuits except the serial interface are turned off.
In measure mode, the LTC6802-1 is used to measure cell
voltages and store the results in memory. Measure mode
will also monitor each cell voltage for overvoltage (OV)
and undervoltage (UV) conditions. In monitor mode, the
device will only monitor cells for UV and OV conditions.
A signal is output on the SDO pin to indicate the UV/OV
status. The serial interface is disabled in monitor mode.
Standby Mode
The LTC6802-1 defaults (powers up) to standby mode.
Standby mode is the lowest possible supply current state.
All circuits are turned off except the serial interface and the
voltage regulator. For the lowest possible standby current
consumption all SPI logic inputs should be set to a logic
1 level. The LTC6802-1 can be programmed for standby
mode by setting the comparator duty cycle configuration
bits, CDC[2:0], to 0. If the part is put into standby mode
while ADC measurements are in progress, the measure-
ments will be interrupted and the cell voltage registers will
be in an indeterminate state. To exit standby mode, the
If fewer than 12 cells are connected to the LTC6802-1
then it is necessary to mask the unused input channels.
The MCxI bits in the configuration registers are used to
mask channels. If the CELL10 bit is high, then the inputs
for cells 11 and 12 are automatically masked.
The LTC6802-1 can monitor UV and OV conditions con-
tinuously. Alternatively, the duty cycle of the UV and OV
comparisons can be reduced or turned off to lower the
overall power consumption. The CDC bits are used to
control the duty cycle.
To initiate cell voltage measurements while in measure
mode, a Start A/D Conversion and Poll Status command
must be sent. After the command has been sent, the
LTC6802-1 will send the A/D converter status using either
the toggle polling or the level polling method, as described
in the Serial Port section. If the CELL10 bit is high, then
only the bottom 10 cell voltages will be measured, thereby
reducing power consumption and measurement time. By
default the CELL10 bit is low, enabling measurement of all
12 cell voltages. During cell voltage measurement com-
mands, UV and OV flag conditions, reflected in the flag
register group, are also updated. When the measurements
are complete, the part will go back to monitoring UV and
OV conditions at the rate designated by the CDC bits.
CDC bits must be written to a value other than 0.
Monitor Mode
Measure Mode
LTC6802-1 is in measure mode when the CDC bits are
programmed with a value from 1 to 7. The IC monitors
each cell voltage and produces an interrupt signal on the
SDO pin indicating all cell voltages are within the UV and
OV limits. There are two methods for indicating the UV/OV
interrupt status: toggle polling (using a 1kHz output signal)
and level polling (using a high or low output signal). The
polling methods are described in the Serial Port section.
The UV/OV limits are set by the VUV and VOV values in
the configuration registers. When a cell voltage exceeds
the UV/OV limits a bit is set in the flag register. The UV
and OV flag status for each cell can be determined using
the Read Flag Register Group .
The LTC6802-1 can be used as a simple monitoring circuit
with no serial interface by pulling the MMB pin low. When
in this mode, the interrupt status is indicated on the SDO
pin using the toggle polling mode described in the Serial
Port section. Unlike serial port polling commands, how-
ever, the toggling is independent of the state of the CSBI
pin. See Figure 6.
When the MMB pin is low, all the device configuration
values are reset to the default states shown in Table 12.
When MMB is held low the VUV, VOV, and CDC register
values are ignored. Instead VUV and VOV use factory-
programmed setings. CDC is set to state 5. The number
of cells to be monitored is set by the logic levels on the
WDTB and GPIO pins, as shown in Table 1.
68021fa
17
相关PDF资料
PDF描述
LTC6803HG-1#TRPBF IC MONITOR BATT STACK 44-SSOP
LTC692CN8 IC MPU SUPERVISORY CIRCUIT 8-DIP
LTC6943HGN#TRPBF IC BUILDNG BLK SWCAP DUAL 16SSOP
LTC695ISW#TRPBF IC MPU SUPERVISRY CIRCUIT 16SOIC
LTC699IN8#PBF IC MPU SUPERVISORY CIRCUIT 8-DIP
相关代理商/技术参数
参数描述
LTC6802IG-2 制造商:LINER 制造商全称:Linear Technology 功能描述:Multicell Addressable Battery Stack Monitor
LTC6802IG-2#3ZZPBF 制造商:Linear Technology 功能描述:
LTC6802IG-2#PBF 功能描述:IC MONITOR BATT STACK 44-SSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 电池管理 系列:- 其它有关文件:STC3100 View All Specifications 特色产品:STC3100 - Battery Monitor IC 标准包装:4,000 系列:- 功能:燃料,电量检测计/监控器 电池化学:锂离子(Li-Ion) 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:8-TSSOP,8-MSOP(0.118",3.00mm 宽) 供应商设备封装:8-MiniSO 包装:带卷 (TR) 其它名称:497-10526-2
LTC6802IG-2#PBF 制造商:Linear Technology 功能描述:IC BATTERY MONITOR LI-ION 50V SSOP44
LTC6802IG-2#TRPBF 功能描述:IC MONITOR BATT STACK 44-SSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 电池管理 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:- 功能:电池监控器 电池化学:碱性,锂离子,镍镉,镍金属氢化物 电源电压:1 V ~ 5.5 V 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:SOT-23-6 供应商设备封装:SOT-6 包装:带卷 (TR)