参数资料
型号: LTC6802IG-1#TRPBF
厂商: Linear Technology
文件页数: 22/38页
文件大小: 0K
描述: IC MONITOR BATT STACK MC 44-SSOP
标准包装: 2,000
功能: 电池监控器
电池化学: 锂离子(Li-Ion)
电源电压: 4 V ~ 50 V
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 44-FSOP(0.209",5.30mm 宽)
供应商设备封装: 44-SSOP
包装: 带卷 (TR)
LTC6802-1
APPLICATIONS INFORMATION
out will be low when any device is busy performing an
A/D conversion and will be high when no device is busy.
Similarly, when polling for interrupt status, the output will
be low when any device has an interrupt condition and will
be high when none has an interrupt condition.
Level polling—Daisy-Chained Broadcast Polling: The SDO
pin (bottom device) or SDI pin (stacked devices) will be
low if a device is busy/in interrupt. If it is not busy/not in
interrupt, the device will pass the level from the SDOI input
to data out (if not the top-of-stack device) or hold the data
out line high (if the top-of-stack device). Therefore, if any
device in the chain is busy or in interrupt, the SDO signal
at the bottom of the stack will be low. If all devices are
not busy/not in interrupt, the SDO signal at the bottom of
the stack will be high.
The master pulls CSBI high to exit polling.
Polling Methods: For A/D conversions, three methods can
be used to determine A/D completion. First, a controller
can start an A/D conversion and wait for the specified
Table 2. Protocol Key
conversion time to pass before reading the results. The
second method is to hold CSBI low after an A/D start
command has been sent. The A/D conversion status will be
output on SDO. A problem with the second method is that
the controller is not free to do other serial communication
while waiting for A/D conversions to complete. The third
method overcomes this limitation. The controller can send
an A/D start command, perform other tasks, and then
send a Poll A/D Converter Status (PLADC) command to
determine the status of the A/D conversions.
For OV/UV interrupt status, the Poll Interrupt Status (PLINT)
command can be used to quickly determine whether
any cell in a stack is in an overvoltage or undervoltage
condition.
Bus Protocols
There are 3 different protocol formats, depicted in Table 3
through Table 5. Table 2 is the key for reading the protocol
diagrams.
PEC
N
Packet error code (CRC-8)
Number of bits
Continuation of protocol
Master-to-slave
Slave-to-master
Complete byte of data
Table 3. Broadcast Poll Command
8
Command
Poll Data
Table 4. Broadcast Read
8
8
8
8
8
8
Command
Data Byte Low
Data Byte High
PEC
Shift Byte 1
Shift Byte N
Table 5. Broadcast Write
8
8
8
8
8
Command
Data Byte Low
Data Byte High
Shift Byte 1
Shift Byte N
68021fa
22
相关PDF资料
PDF描述
LTC6803HG-1#TRPBF IC MONITOR BATT STACK 44-SSOP
LTC692CN8 IC MPU SUPERVISORY CIRCUIT 8-DIP
LTC6943HGN#TRPBF IC BUILDNG BLK SWCAP DUAL 16SSOP
LTC695ISW#TRPBF IC MPU SUPERVISRY CIRCUIT 16SOIC
LTC699IN8#PBF IC MPU SUPERVISORY CIRCUIT 8-DIP
相关代理商/技术参数
参数描述
LTC6802IG-2 制造商:LINER 制造商全称:Linear Technology 功能描述:Multicell Addressable Battery Stack Monitor
LTC6802IG-2#3ZZPBF 制造商:Linear Technology 功能描述:
LTC6802IG-2#PBF 功能描述:IC MONITOR BATT STACK 44-SSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 电池管理 系列:- 其它有关文件:STC3100 View All Specifications 特色产品:STC3100 - Battery Monitor IC 标准包装:4,000 系列:- 功能:燃料,电量检测计/监控器 电池化学:锂离子(Li-Ion) 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:8-TSSOP,8-MSOP(0.118",3.00mm 宽) 供应商设备封装:8-MiniSO 包装:带卷 (TR) 其它名称:497-10526-2
LTC6802IG-2#PBF 制造商:Linear Technology 功能描述:IC BATTERY MONITOR LI-ION 50V SSOP44
LTC6802IG-2#TRPBF 功能描述:IC MONITOR BATT STACK 44-SSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 电池管理 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:- 功能:电池监控器 电池化学:碱性,锂离子,镍镉,镍金属氢化物 电源电压:1 V ~ 5.5 V 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:SOT-23-6 供应商设备封装:SOT-6 包装:带卷 (TR)