参数资料
型号: MAX11080GUU/V+T
厂商: Maxim Integrated Products
文件页数: 21/29页
文件大小: 0K
描述: IC LI/BATTERY MANAGEMENT 38TSSOP
其它有关文件: Automotive Product Guide
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 2,500
功能: 电池监控器
电池化学: 锂离子(Li-Ion)
电源电压: 6 V ~ 72 V
工作温度: -40°C ~ 105°C
安装类型: 表面贴装
封装/外壳: 38-TFSOP(0.173",4.40mm 宽)
供应商设备封装: 38-TSSOP
包装: 带卷 (TR)
12-Channel, High-Voltage
Battery-Pack Fault Monitors
shorted together, but Cell 1 must always be populated.
The designer can choose which cell inputs to leave
unused. The example application circuits recommended
are the most efficient configurations.
At power-up, the part compares the voltage applied to
each cell input with a nominal cell-detection threshold
voltage of 0.7V. If the cell voltage is less than the cell-
detection threshold, undervoltage detection is disabled
for that cell input. If the voltage at the input is 0.7V or
greater, undervoltage detection is specified by the state
of the UVSEL_ inputs. Overvoltage detection is always
enabled for all cell-voltage inputs. The cell-connection
detection occurs just before the MAX11080/MAX11081
are fully functional as shown in Figure 12 under NUMBER
OF CELLS DETECTED.
TOPSEL Function
The TOPSEL pin is used to indicate to a device whether
it is the top device in the daisy-chain stack. The top
daisy-chain device is responsible for generating the
heartbeat signal at the top of the ALRM_ pin bus. This
heartbeat propagates along the chain toward the host.
To designate a device as the top device, the TOPSEL
pin should be connected to V AA . For all other devices
in a daisy-chain, this pin should be connected to
AGND. The TOPSEL pin has a weak internal pulldown
resistor, but this resistor should not be relied upon as
the sole means of setting the TOPSEL logic level. The
logic level of the TOPSEL pin is not latched internally at
startup and is continuously sampled during operation.
The ALRM U input should be connected to GND U for the
top module as good design practice to prevent noise
pickup even though the input logic level is ignored.
For a single device or DC-coupled daisy-chain applica-
tion, the device can be operated in an alarm level mode
instead of heartbeat mode by tying TOPSEL to AGND for
all devices. In this mode of operation, ALRM L passes the
signal of ALRM U when the device is not in the alarm state.
ALRM L drives high when the device is in the alarm state.
ALRM U must be tied to GND U for the topmost device for
this application. The following table summarizes the
operation of TOPSEL and ALRM L for level mode:
Internal Self-Test
The MAX11080/MAX11081 perform an internal self-test
during power-up according to the linear regulator
power-up flowchart (Figure 12). Each overvoltage com-
parator is tested for the ability to detect an internally
generated overvoltage test condition. This is done by
using the ground voltage level as the threshold refer-
ence in place of the usual threshold level. Figure 8
shows the connection for this test-mode compare level.
If all comparators can detect the internally generated
overvoltage test event, part operation continues. If any
comparator fails to detect the internally generated over-
voltage test event, a fault is signaled using the ALRM L
pin. The device must be power cycled to retest the
comparators and attempt to clear this fault condition.
Failure Mode and Effects Analysis
High-voltage battery-pack systems can be subjected to
severe stresses during in-service fault conditions and
could experience similar conditions during the manufac-
turing and assembly process. The MAX11080/MAX11081
are designed with high regard to these potential states.
Open and short circuits at the package level must be
readily detected for fault diagnosis and should be toler-
ated whenever possible. A number of circuits are
employed within the MAX11080/MAX11081 specifically
to detect such conditions and progress to a known
device state. Table 3 summarizes other conditions typi-
cal in a normal manufacturing process along with their
effect on the MAX11080/MAX11081 devices.
See Table 4 for the FMEA analysis of the MAX11080/
MAX11081. If the cell voltage is within the monitor
range, the heartbeat signal on ALRM L resumes once
the fault condition (either open or short) is removed,
unless otherwise specified.
TOPSEL
0
1
ALRM U
0
X
ALRM L
No alarm
ALRM U
Heartbeat
Alarm
1
1
______________________________________________________________________________________
21
相关PDF资料
PDF描述
MAX11081GUU+T IC FAULT MON BATT 12CH 38-TSSOP
MAX11081GUU/V+T IC FAULT MON BATT 12CH 38TSSOP
AIUR-10-330K INDUCTOR POWER 33UH 10% T/H
MAX11080GUU+T IC LI/BATTERY MANAGEMENT 38TSSOP
V48C15C75B3 CONVERTER MOD DC/DC 15V 75W
相关代理商/技术参数
参数描述
MAX11080IUU+ 功能描述:电池管理 12 Ch Hi Volt Batt Pack Fault Monitor RoHS:否 制造商:Texas Instruments 电池类型:Li-Ion 输出电压:5 V 输出电流:4.5 A 工作电源电压:3.9 V to 17 V 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:VQFN-24 封装:Reel
MAX11080IUU+T 功能描述:电池管理 12 Ch Hi Volt Batt Pack Fault Monitor RoHS:否 制造商:Texas Instruments 电池类型:Li-Ion 输出电压:5 V 输出电流:4.5 A 工作电源电压:3.9 V to 17 V 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:VQFN-24 封装:Reel
MAX11081GUU/V+ 功能描述:电池管理 12 Ch Hi Volt Batt Pack Fault Monitor RoHS:否 制造商:Texas Instruments 电池类型:Li-Ion 输出电压:5 V 输出电流:4.5 A 工作电源电压:3.9 V to 17 V 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:VQFN-24 封装:Reel
MAX11081GUU/V+T 功能描述:电池管理 12 Ch Hi Volt Batt Pack Fault Monitor RoHS:否 制造商:Texas Instruments 电池类型:Li-Ion 输出电压:5 V 输出电流:4.5 A 工作电源电压:3.9 V to 17 V 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:VQFN-24 封装:Reel
MAX11081GUU+ 功能描述:电池管理 12 Ch Hi Volt Batt Pack Fault Monitor RoHS:否 制造商:Texas Instruments 电池类型:Li-Ion 输出电压:5 V 输出电流:4.5 A 工作电源电压:3.9 V to 17 V 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:VQFN-24 封装:Reel