参数资料
型号: MAX11359AETL+T
厂商: Maxim Integrated Products
文件页数: 38/67页
文件大小: 0K
描述: IC DAS SYSTEM 16BIT 40-TQFN
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 2,500
类型: 数据采集系统(DAS)
分辨率(位): 16 b
采样率(每秒): 512
数据接口: MICROWIRE?,QSPI?,串行,SPI?
电压电源: 模拟和数字
电源电压: 1.8 V ~ 3.6 V
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 40-WFQFN 裸露焊盘
供应商设备封装: 40-TQFN-EP(6x6)
包装: 带卷 (TR)
MAX11359A
16-Bit Data-Acquisition System with ADC, DAC,
UPIOs, RTC, Voltage Monitors, and Temp Sensor
43
Maxim Integrated
The RTC register stores the 40-bit second and subsec-
ond count of the respective time-of-day and system
clocks.
SEC<31:0>: The second bits store the time-of-day
clock settings. It is a 32-bit binary counter with 1s reso-
lution that can keep time for a span of over 136 years.
Firmware in the C can translate this time count to units
that are meaningful to the system (i.e., translate to cal-
endar time or as an elapsed time from some predefined
time = 0, such as January 1, 2000). The RTC runs con-
tinuously as long as RTCE = 1 (see the
CLK_CNTL
Register section) and does not stop for reads or writes.
The counter increments when the subsecond counter
overflows. Set RWE = 1 to enable writing to the RTC
register. After writing to RWE, perform another write
and set RTCE = 1 to enable the RTC. A 40-bit burst
write operation, starting with SEC31 and finishing with
SUB0 is required to set the RTC second and subsec-
ond bits. If
CS is brought high before the 40th rising
SCLK edge, the write is aborted and the RTC contents
are unchanged. The RTC register is loaded on the ris-
ing SCLK edge of the 40th bit (SUB0). A 40-bit burst
read operation, starting with SEC31 and finishing with
SUB0, is required to retrieve the current RTC second
and subsecond counts. The read command can be
aborted prior to receiving the 40th bit (SUB0) by raising
CS and any RTC data read to that point is valid. When
the read command is received, a snapshot of a valid
RTC second count is latched to avoid reading an erro-
neous, transitioning RTC value. Due to the asynchro-
nous nature of RTC reads, it is possible to have a
maximum 1s error between the actual and reported
times from the time-of-day clock. To prevent the data
from changing during a read operation, complete reads
of the RTC register in less than 1ms. The power-on
default state is 0000 0000 hex.
SUB<7:0>: The subsecond bits store the system clock.
This 8-bit binary counter has 3.9ms resolution (1/256Hz)
and a span of 1s. The subsecond counter increments in
single counts from 00 hex to FF hex before rolling over
again to 00 hex, at which time the RTC second counter
(SEC<31:0>) increments. The RTC runs continuously
(as long as RTCE = 1) and does not stop for reads or
writes. A 256Hz clock, derived from the 32kHz crystal,
increments this counter. Set the RWE = 1 bit to enable
writing to the RTC register. After writing to RWE, perform
another write, setting RTCE = 1, to enable the RTC. A
40-bit burst write operation, starting with SEC31 and fin-
ishing with SUB0, is required to set the RTC second and
subsecond bits. If
CS is brought high before the 40th
rising SCLK edge, the write is aborted and the RTC con-
tents are unchanged. The RTC register is loaded on the
rising SCLK edge of the 40th bit (SUB0). A 40-bit burst
read operation, starting with SEC31 and finishing with
SUB0, is required to retrieve the current RTC second
and subsecond counts. The read command can be
aborted prior to receiving the 40th bit (SUB0) by raising
CS, and any RTC data read to that point is valid. When
the read command is received, a snapshot of a valid
RTC second count is latched to avoid reading an erro-
neous, transitioning RTC value. Due to the asynchro-
nous nature of RTC reads, it is possible to have a
maximum 1s error between the actual and reported
times from the time-of-day clock. To prevent the data
from changing during a read operation, complete reads
of the RTC registers occur in less than 1ms. The power-
on default state is 00 hex.
MSB
SEC31
SEC30
SEC29
SEC28
SEC27
SEC26
SEC25
SEC24
SEC23
SEC22
SEC21
SEC20
SEC19
SEC18
SEC17
SEC16
SEC15
SEC14
SEC13
SEC12
SEC11
SEC10
SEC9
SEC8
SEC7
SEC6
SEC5
SEC4
SEC3
SEC2
SEC1
SEC0
LSB
SUB7
SUB6
SUB5
SUB4
SUB3
SUB2
SUB1
SUB0
RTC Register (Power-On State: 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000)
相关PDF资料
PDF描述
MAX115CAX+ IC DAS SYSTEM 12BIT 36-SSOP
MAX1221BETX+T IC ADC/DAC 12BIT W/FIFO 36TQFNEP
MAX1257BETM+T IC ADC/DAC 12BIT 48-TQFN
MAX125CCAX+D IC DAS 14BIT 2X4CH 36-SSOP
MAX1271AENG+ IC ADC 12BIT 8CH 24-DIP
相关代理商/技术参数
参数描述
MAX1135BCAP 功能描述:模数转换器 - ADC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MAX1135BCAP+ 功能描述:模数转换器 - ADC 16-Bit 150ksps 3.3V Single Supply RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MAX1135BCAP+T 功能描述:模数转换器 - ADC 16-Bit 150ksps 3.3V Single Supply RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MAX1135BCAP-T 功能描述:模数转换器 - ADC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MAX1135BEAP 功能描述:模数转换器 - ADC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32