NCP1246
S min +
X2 Cap Discharge Feature
The X2 capacitor discharging feature is offered by usage
of the NCP1246. This feature save approx. 16 mW – 25 mW
input power depending on the EMI filter X2 capacitors
volume and it saves the external components count as well.
The discharge feature is ensured via the start ? up current
source with a dedicated control circuitry for this function.
The X2 capacitors are being discharged by current defined
as I start2 when this need is detected.
There is used a dedicated structure called ac line unplug
detector inside the X2 capacitor discharge control circuitry.
See the Figure 50 for the block diagram for this structure and
Figures 51, 52, 53 and 54 for the timing diagrams. The basic
idea of ac line unplug detector lies in comparison of the
direct sample of the high voltage obtained via the high
voltage sensing structure with the delayed sample of the high
voltage. The delayed signal is created by the sample & hold
structure.
The comparator used for the comparison of these signals
is without hysteresis inside. The resolution between the
slopes of the ac signal and dc signal is defined by the
sampling time T SAMPLE and additional internal offset N OS .
These parameters ensure the noise immunity as well. The
additional offset is added to the picture of the sampled HV
signal and its analog sum is stored in the C 1 storage
capacitor. If the voltage level of the HV sensing structure
output crosses this level the comparator CMP output signal
resets the detection timer and no dc signal is detected. The
additional offset N OS can be measured as the V HV(hyst) on
the HV pin. If the comparator output produces pulses it
means that the slope of input signal is higher than set
resolution level and the slope is positive. If the comparator
output produces the low level it means that the slope of input
signal is lower than set resolution level or the slope is
negative. There is used the detection timer which is reset by
any edge of the comparator output. It means if no edge
comes before the timer elapses there is present only dc signal
or signal with the small ac ripple at the HV pin. This type of
the ac detector detects only the positive slope, which fulfils
the requirements for the ac line presence detection.
In case of the dc signal presence on the high voltage input,
the direct sample of the high voltage obtained via the high
voltage sensing structure and the delayed sample of the high
voltage are equivalent and the comparator produces the low
level signal during the presence of this signal. No edges are
present at the output of the comparator, that’s why the
detection timer is not reset and dc detect signal appears.
The minimum detectable slope by this ac detector is given
by the ration between the maximum hysteresis observed at
HV pin V HV(hyst),max and the sampling time:
V HV(hyst),max
(eq. 1)
T sample
Than it can be derived the relationship between the
minimum detectable slope and the amplitude and frequency
of the sinusoidal input voltage:
V HV(hyst),max 5
V max + +
2 @ p @ f @ T sample 2 @ p @ 35 @ 1 @ 10 ? 3 (eq. 2)
+ 22.7 V
The minimum detectable AC RMS voltage is 16 V at
frequency 35 Hz, if the maximum hysteresis is 5 V and
sampling time is 1 ms.
The X2 capacitor discharge feature is available in any
controller operation mode to ensure this safety feature. The
detection timer is reused for the time limiting of the
discharge phase, to protect the device against overheating.
The discharging process is cyclic and continues until the ac
line is detected again or the voltage across the X2 capacitor
is lower than V HV(min ). This feature ensures to discharge
quite big X2 capacitors used in the input line filter to the safe
level. It is important to note that it is not allowed to
connect HV pin to any dc voltage due this feature. e.g.
directly to bulk capacitor.
During the HV sensing or X2 cap discharging the V CC net
is kept above the V CC(off) voltage by the Self ? Supply in any
mode of device operation to supply the control circuitry.
During the discharge sequence is not allowed to start ? up the
device.
http://onsemi.com
20
相关PDF资料
PDF描述
189-015-513R571 CONN DB15 FEM-FEM .625" SPACING
ABB56DHFD-S578 EDGECARD 112POS .050 SMD W/POSTS
RCM10DCAN-S189 CONN EDGECARD 20POS R/A .156 SLD
RSO-4815S CONV DC/DC 1W 36-72VIN 15VOUT
RSC49DREF-S13 CONN EDGECARD 98POS .100 EXTEND
相关代理商/技术参数
参数描述
NCP1246B100DR2G 制造商:ONSEMI 制造商全称:ON Semiconductor 功能描述:Fixed Frequency Current Mode Controller for Flyback Converters
NCP1246B65DR2G 制造商:ONSEMI 制造商全称:ON Semiconductor 功能描述:Fixed Frequency Current Mode Controller for Flyback Converters
NCP1246BD065R2G 功能描述:电流型 PWM 控制器 FIXED FREQ (65KHZ) CURREN RoHS:否 制造商:Texas Instruments 开关频率:27 KHz 上升时间: 下降时间: 工作电源电压:6 V to 15 V 工作电源电流:1.5 mA 输出端数量:1 最大工作温度:+ 105 C 安装风格:SMD/SMT 封装 / 箱体:TSSOP-14
NCP1246BD100R2G 功能描述:电流型 PWM 控制器 FIXED FREQ (65KHZ) CURREN RoHS:否 制造商:Texas Instruments 开关频率:27 KHz 上升时间: 下降时间: 工作电源电压:6 V to 15 V 工作电源电流:1.5 mA 输出端数量:1 最大工作温度:+ 105 C 安装风格:SMD/SMT 封装 / 箱体:TSSOP-14
NCP1246-D 制造商:ONSEMI 制造商全称:ON Semiconductor 功能描述:Fixed Frequency Current Mode Controller for Flyback Converters