参数资料
型号: RXM-900-HP3-SPS
厂商: Linx Technologies Inc
文件页数: 6/13页
文件大小: 0K
描述: RECEIVER RF 902-928MHZ 8P/100S
产品变化通告: Internal Component Change 25/Aug/2011
标准包装: 10
系列: HP3
频率: 902MHz ~ 928MHz
灵敏度: -100dBm
数据传输率 - 最大: 56 kbps
调制或协议: FM,FSK
应用: 家庭/工业自动化,远程访问,安全警报
电流 - 接收: 18mA
数据接口: PCB,表面贴装
天线连接器: PCB,表面贴装
特点: 多通道,模拟和数字数据
电源电压: 2.8 V ~ 13 V
工作温度: -30°C ~ 85°C
封装/外壳: 18-SMD 模块
供应商设备封装: 18-SIP
包装: 管件
其它名称: Q3400415
CHANNEL SELECTION
SERIAL CHANNEL SELECTION TABLE
Parallel Selection
All HP3 receiver models feature eight
parallel selectable channels. Parallel
Mode is selected by grounding the
MODE line. In this mode, channel
CS2
0
0
0
0
1
1
CS1
0
0
1
1
0
0
CS0
0
1
0
1
0
1
Channel
0
1
2
3
4
5
Frequency
903.37
906.37
907.87
909.37
912.37
915.37
CHANNEL TX FREQUENCY
0 902.62
1 902.87
2 903.12
3 903.37
4 903.62
RX LO
867.92
868.17
868.42
868.67
868.92
CHANNEL
51
52
53
54
55
TX FREQUENCY
915.37
915.62
915.87
916.12
916.37
RX LO
880.67
880.92
881.17
881.42
881.67
selection is determined by the logic
states of pins CS0, CS1, and CS2, as
1                 1                 0                        6                           919.87
1 1 1 7 921.37
shown in the adjacent table. A ‘0’ Table 2: Parallel Channel Selection Table
represents ground and a ‘1’ the positive supply. The on-board microprocessor
performs all PLL loading functions, eliminating external programming and
allowing channel selection via DIP switches or a product’s processor.
Serial Selection
In addition to the Parallel Mode, PS versions of the HP3 also feature 100 serially
selectable channels. The Serial Mode is entered when the MODE line is left open
or held high. In this condition, CS1 and CS2 become a synchronous serial port,
with CS1 serving as the clock line and CS2 as the data line. The module is easily
programmed by sending and latching the binary number (0 to 100) of the desired
channel (see the adjacent Serial Channel Selection Table). With no additional
effort, the module’s microprocessor handles the complex PLL loading functions.
5 903.87
6 904.12
7 904.37
8 904.62
9 904.87
10 905.12
11 905.37
12 905.62
13 905.87
14 906.12
15 906.37
16 906.62
17 906.87
18 907.12
19 907.37
20 907.62
869.17
869.42
869.67
869.92
870.17
870.42
870.67
870.92
871.17
871.42
871.67
871.92
872.17
872.42
872.67
872.92
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
916.62
916.87
917.12
917.37
917.62
917.87
918.12
918.37
918.62
918.87
919.12
919.37
919.62
919.87
920.12
920.37
881.92
882.17
882.42
882.67
882.92
883.17
883.42
883.67
883.92
884.17
884.42
884.67
884.92
885.17
885.42
885.67
straightforward; however,
Loading is initiated by
taking the clock line high
and the data line low as
8μs
The      Serial      Mode      is
Note 2
Data
minimum timings and bit
Note 1
order must be followed. Clock
T0
1ms
shown. The eight-bit 25μs
T1
Variable Data
1 2 3 4 5 6 7 8
T3
T2 5μs
5μs
T4
Note 3
21 907.87
22 908.12
23 908.37
24 908.62
25 908.87
26 909.12
27 909.37
28 909.62
29 909.87
873.17
873.42
873.67
873.92
874.17
874.42
874.67
874.92
875.17
72
73
74
75
76
77
78
79
80
920.62
920.87
921.12
921.37
921.62
921.87
922.12
922.37
922.62
885.92
886.17
886.42
886.67
886.92
887.17
887.42
887.67
887.92
channel number is then
1) Loading begins when clock line is high and data line is taken low
30 910.12
875.42
81
922.87
888.17
clocked-in one bit at a 2) Ensure that edge is fully risen prior to high-clock transition
31 910.37
875.67
82
923.12
888.42
time, with the LSB first.
3) Both lines high triggers automatic latch
32 910.62
875.92
83
923.37
888.67
(T0) Time between packets or prior to data startup ................................1mS
(T1) Data-LO / Clock-HI to Data-LO / Clock-LO .......................................25μS
(T2) Clock-LO to Clock-HI ...........................................................................5μS
(T3) Clock-HI to Clock-LO ...........................................................................8μS
(T4) Data-HI / Clock-HI .................................................................................5μS
Total Packet Time ......................................................................................157μS
Figure 13: PLL Serial Data Timing
min.
min.
min.
min.
min.
min.
33 910.87
34 911.12
35 911.37
36 911.62
37 911.87
38 912.12
39 912.37
40 912.62
41 912.87
876.17
876.42
876.67
876.92
877.17
877.42
877.67
877.92
878.17
84
85
86
87
88
89
90
91
92
923.62
923.87
924.12
924.37
924.62
924.87
925.12
925.37
925.62
888.92
889.17
889.42
889.67
889.92
890.17
890.42
890.67
890.92
There is no maximum time for this process, only the minimum times that must be
observed. After the eighth bit, both the clock and data lines should be taken high
to trigger the automatic data latch. A typical software routine can complete the
loading sequence in under 200uS. Sample code is available on the Linx website.
NOTE: When the module is powered up in the Serial Mode, it will default to channel 50 until changed
by user software. This allows testing apart from external programming and prevents out-of-band
operation. When programmed properly, the dwell time on this default channel can be less than 200uS.
Channel 50 is not counted as a usable channel since data errors may occur as transmitters also default
to channel 50 on startup. If a loading error occurs, such as a channel number >100 or a timing problem,
42 913.12
43 913.37
44 913.62
45 913.87
46 914.12
47 914.37
48 914.62
49 914.87
50* 915.12
878.42
878.67
878.92
879.17
879.42
879.67
879.92
880.17
880.42
93
94
95
96
97
98
99
100
925.87
926.12
926.37
926.62
926.87
927.12
927.37
927.62
= Also available in Parallel
891.17
891.42
891.67
891.92
892.17
892.42
892.67
892.92
Mode
the receiver will default to serial channel 0. This is useful for debugging as it verifies serial port activity.
Page 10
*See NOTE on previous page.
Page 11
相关PDF资料
PDF描述
M50100SB1600 MODULE POWER 100A 1600V BRIDGE
M50100TB400 MODULE POWER 100A 400V 3PH BRDG
M5060TB1600 MODULE POWER 60A 1600V 3PH BRDG
EKMB1301113K SENSOR PIR STD TYPE 6UA
M50100SB1000 MODULE POWER 100A 1000V BRIDGE
相关代理商/技术参数
参数描述
RXM-916-ES 功能描述:射频模块 RF Receiver 916MHz RoHS:否 制造商:Linx Technologies 产品:Transceiver Modules 频带:902 MHz to 928 MHz 输出功率:- 15.5 dBm to + 12.5 dBm 接口类型:UART 工作电源电压:- 0.3 VDC to + 5.5 VDC 传输供电电流:38.1 mA 接收供电电流:22.7 mA 天线连接器类型:U.FL 最大工作温度:+ 85 C 尺寸:1.15 mm x 0.63 mm x 0.131 mm
RXM-916-ES_ 功能描述:RECEIVER RF 916MHZ 16PIN SMD RoHS:是 类别:RF/IF 和 RFID >> RF 接收器 系列:- 产品培训模块:Lead (SnPb) Finish for COTS 产品变化通告:Product Discontinuation 09/Jan/2012 标准包装:50 系列:* 频率:850MHz ~ 2.175GHz 灵敏度:- 数据传输率 - 最大:- 调制或协议:- 应用:* 电流 - 接收:* 数据接口:PCB,表面贴装 存储容量:- 天线连接器:PCB,表面贴装 特点:- 电源电压:4.75 V ~ 5.25 V 工作温度:0°C ~ 85°C 封装/外壳:40-WFQFN 裸露焊盘 供应商设备封装:40-TQFN-EP(6x6) 包装:托盘
RX-MFR-RNLK-00 功能描述:KIT EVAL S4100 MULTI-FUNC READER RoHS:否 类别:RF/IF 和 RFID >> 过时/停产零件编号 系列:- 标准包装:1 系列:- 类型:用于 200/300 系列的欧盟开发套件 适用于相关产品:Zensys RF 模块 所含物品:开发板,模块,编程器,软件,线缆,电源 其它名称:703-1019Q3225667
RXM-GNSS-GM-B 制造商:Linx Technologies Inc 功能描述:GNSS RX MODULE GM SERIES 制造商:Linx Technologies Inc 功能描述:GM Series Global 3 - 4.3 V SMT -161 db 57.6 kbit/s GNSS Receiver Module 制造商:Linx Technologies Inc 功能描述:GPS Modules GM Series Receiver GNSS Module Bulk 制造商:LINX TECHNOLOGIES 功能描述:GM Series Global 3 - 4.3 V SMT -161 db 57.6 kbit/s GNSS Receiver Module
RXM-GNSS-GM-T 制造商:Linx Technologies Inc 功能描述:GNSS RX MODULE GM SERIES