![](http://datasheet.mmic.net.cn/120000/SAK-C167CS-4R33M_datasheet_3574888/SAK-C167CS-4R33M_55.png)
C167CS-4R
C167CS-L
Data Sheet
51
V2.2, 2001-08
Input leakage current (all other)
IOZ2 CC –
±500
nA
0.45 V <
VIN
<
VDD
RSTIN inactive current6)
IRSTH
7)
–
-10
A
VIN = VIH1
IRSTL
8)
-100
–
A
VIN = VIL
READY/RD/WR inact. current9)
IRWH
–
-40
A
VOUT = 2.4 V
READY/RD/WR active current
9)IRWL
-500
–
A
VOUT = VOLmax
–
40
A
VOUT = VOLmax
IALEH
500
–
A
VOUT = 2.4 V
Port 6 inactive current
9)IP6H
–
-40
A
VOUT = 2.4 V
-500
–
A
VOUT = VOL1max
PORT0 configuration current10)
IP0H
–
-10
A
VIN = VIHmin
-100
–
A
VIN = VILmax
XTAL1 input current
IIL
CC –
±20
A0 V < VIN < VDD
Pin capacitance11)
(digital inputs/outputs)
CIO CC –
10
pF
f = 1 MHz
TA = 25 °C
1) Keeping signal levels within the levels specified in this table, ensures operation without overload conditions.
For signal levels outside these specifications also refer to the specification of the overload current
IOV.
2) For pin RSTIN this specification is only valid in bidirectional reset mode.
3) The maximum deliverable output current of a port driver depends on the selected output driver mode, see
4) As a rule, with decreasing output current the output levels approach the respective supply level (V
OL → VSS,
VOH → VDD). However, only the levels for nominal output currents are guaranteed.
5) This specification is not valid for outputs which are switched to open drain mode. In this case the respective
output will float and the voltage results from the external circuitry.
6) These parameters describe the RSTIN pullup, which equals a resistance of ca. 50 to 250 k.
7) The maximum current may be drawn while the respective signal line remains inactive.
8) The minimum current must be drawn in order to drive the respective signal line active.
9) This specification is valid during Reset and during Hold-mode or Adapt-mode. During Hold-mode Port 6 pins
are only affected, if they are used (configured) for CS output and the open drain function is not enabled. The
READY-pullup is always active, except for Powerdown mode.
10) This specification is valid during Reset and during Adapt-mode.
11) Not 100% tested, guaranteed by design and characterization.
DC Characteristics (cont’d)
(Operating Conditions apply)1)
Parameter
Symbol
Limit Values
Unit Test Condition
min.
max.