AD converter control register 2
ADCCR2
7
6
5
4
3
2
1
0
(0x0035)
Bit Symbol
EOCF
ADBF
-
"0"
ACK
Read/Write
R
W
R/W
After reset
0
EOCF
AD conversion end flag
0:
1:
Before conversion or during conversion
Conversion end
ADBF
AD conversion BUSY flag
0:
1:
AD conversion being halted
AD conversion being executed
ACK
AD conversion time select (exam-
ples of AD conversion time are
shown in the table below)
000:
001:
010:
011:
100:
101:
110:
111:
39/fcgck
78/fcgck
156/fcgck
312/fcgck
624/fcgck
1248/fcgck
Reserved
Note 1: Make sure that you make the ACK setting when AD conversion is in a halt condition (ADCCR2<ADBF>="0").
Note 2: Make sure that you write "0" to bit 3 of ADCCR2.
Note 3: If STOP, IDLE0 or SLOW mode is started, EOCF and ADBF are initialized to "0".
Note 4: If the AD converted value register (ADCDRH) is read, EOCF is cleared to "0". It is also cleared to "0" if AD conversion is
started (ADCCR1<ADRS>="1") without reading ADCDRH after completing AD conversion in single mode.
Note 5: If an instruction to read ADCCR2 is executed, 0 is read from bits 3 through 5.
Table 20-1 ACK Settings and Conversion Times Relative to Frequencies
Frequency (fcgck)
ACK setting
Conversion
time
10MHz
8MHz
4MHz
2MHz
5MHz
2.5MHz
1MHz
0.5MHz
0.25 MHz
000
39/fcgck
-
19.5 μs
-
15.6 μs
39.0 μs
78.0 μs
156.0 μs
001
78/fcgck
-
19.5 μs
39.0 μs
15.6 μs
31.2 μs
78.0 μs
156.0 μs
-
010
156/fcgck
15.6 μs
19.5 μs
39.0 μs
78.0 μs
31.2 μs
62.4 μs
156.0 μs
-
011
312/fcgck
31.2 μs
39.0 μs
78.0 μs
156.0 μs
62.4 μs
124.8 μs
-
100
624/fcgck
62.4 μs
78.0 μs
156.0 μs
-
124.8 μs
-
101
1248/fcgck
124.8 μs
156.0 μs
-
11*
Reserved
Note 1: Spaces indicated by "-" in the above table mean that it is prohibited to establish conversion times in these spaces.
fcgck: High Frequency oscillation clock [Hz]
Note 2: Above conversion times do not include the time shown below.
- Time from when ADCCR1<ADRS> is set to 1 to when AD conversion is started
- Time from when AD conversion is finished to when a converted value is stored in ADCDRL and ADCDRH.
If ACK = 00*, the longest conversion time is 10/fcgck (s). If ACK = 01*, it is 32/fcgck (s). If ACK = 10*, it is 128/fcgck(s).
Note 3: The conversion time must be longer than the following time by analog reference voltage (VAREF).
- VAREF = 4.5 to 5.5 V
15.6 μs or longer
- VAREF = 2.7 to 5.5 V
31.2 μs or longer
- VAREF = 2.2 to 5.5 V
124.8 μs or longer
TMP89FM42
20. 10-bit AD Converter (ADC)
20.2 Control
Page 310
RA002