参数资料
型号: X9118TV14-2.7
厂商: Intersil
文件页数: 15/17页
文件大小: 0K
描述: IC XDCP SGL 1024TAP 100K 14TSSOP
标准包装: 95
系列: XDCP™
接片: 1024
电阻(欧姆): 100k
电路数: 1
温度系数: 标准值 ±300 ppm/°C
存储器类型: 非易失
接口: I²C(设备位址)
电源电压: 2.7 V ~ 5.5 V
工作温度: 0°C ~ 70°C
安装类型: 表面贴装
封装/外壳: 14-TSSOP(0.173",4.40mm 宽)
供应商设备封装: 14-TSSOP
包装: 管件
7
FN8161.4
December 4, 2009
Instruction and Register Description
DEVICE ADDRESSING
Wiper Counter Register (WCR)
The X9118 contains a Wiper Counter Register (see Table 4)
for the XDCP potentiometer. The WCR is equivalent to a
serial-in, parallel-out register/counter with its outputs
decoded to select one of 1024 switches along its resistor
array. The contents of the WCR can be altered in one of
three ways:
1. It may be written directly by the host via the write Wiper
Counter Register instruction (serial load)
2. It may be written indirectly by transferring the contents of
one of four associated Data Registers via the XFR Data
register
3. It is loaded with the contents of its Data Register zero
(R0) upon power-up.
The Wiper Counter Register is a volatile register; that is, its
contents are lost when the X9118 is powered-down. Although
the register is automatically loaded with the value in DR0
upon power-up, this may be different from the value present at
power-down. Power-up guidelines are recommended to
ensure proper loadings of the DR0 value into the WCR.
Data Registers (DR)
The potentiometer has four 10-bit non-volatile Data
Registers. These can be read or written directly by the host.
Data can also be transferred between any of the four data
registers and the Wiper Counter Register. All operations
changing data in one of the Data Registers is a nonvolatile
operation and will take a maximum of 10ms.
If the application does not require storage of multiple
settings for the potentiometer, the Data Registers can be
used as regular memory locations for system parameters or
user preference data.
Bit 9–Bit 0 are used to store one of the 1024 wiper position
(0 ~1023).
Four of the six instructions are four bytes in length. These
instructions are:
Read Wiper Counter Register – read the current wiper
position of the potentiometer,
Write Wiper Counter Register – change current wiper
position of the potentiometer,
Read Data Register – read the contents of the selected
Data Register;
Write Data Register – write a new value to the selected
Data Register.
The basic sequence of the four byte instructions is illustrated
in Figure 3. These four-byte instructions exchange data
between the WCR and one of the Data Registers. A transfer
from a data register to a WCR is essentially a write to a static
RAM, with the static RAM controlling the wiper position. The
response of the wiper to this action will be delayed by tWRL. A
transfer from the WCR (current wiper position), to a data
register is a write to nonvolatile memory and takes a minimum
of tWR to complete. The transfer can occur between the
potentiometer and one of its associated registers.
Two instructions (see Figure 4) require a two-byte sequence
to complete. These instructions transfer data between the
host and the X9118; either between the host and one of the
Data Registers or directly between the host and the Wiper
Counter Register. These instructions are:
XFR Data Register to Wiper Counter Register – This
transfers the contents of one specified Data Register to
the Wiper Counter Register.
XFR Wiper Counter Register to Data Register –This
transfers the contents of the specified Wiper Counter
Register to the specified Data Register.
Other
POWER-UP AND DOWN REQUIREMENTS
At all times, the V+ voltage must be greater than or equal to
the voltage at RH or RL, and the voltage at RH or RL must be
greater than or equal to the voltage at V-. During power-up
and power down, VCC, V+, and V- must reach their final
values within 1ms of each other.
TABLE 4. WIPER CONTROL REGISTER, WCR (10-BIT), WCR9–WCR0: USED TO STORE THE CURRENT WIPER POSITION (VOLATILE, V)
WCR9
WCR8
WCR7
WCR6
WCR5
WCR4
WCR3
WCR2
WCR1
WCR0
VVV
VVVVVVV
(MSB)
(LSB)
TABLE 5. DATA REGISTER, DR (10-BIT), BIT 9–BIT 0: USED TO STORE WIPER POSITIONS OR DATA (NON-VOLATILE, NV)
BIT 9
BIT 8
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
NV
MSB
LSB
X9118
相关PDF资料
PDF描述
VE-27X-MY-F2 CONVERTER MOD DC/DC 5.2V 50W
V375A36T600BG CONVERTER MOD DC/DC 36V 600W
VE-27X-MY-F1 CONVERTER MOD DC/DC 5.2V 50W
M83723/95R1005N CONN PLUG 5POS STRAIGHT W/SCKT
VE-26N-MW-S CONVERTER MOD DC/DC 18.5V 100W
相关代理商/技术参数
参数描述
X9118TV14I 功能描述:IC DCP 100K 1024TP 14TSSOP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 数字电位器 系列:XDCP™ 标准包装:2,500 系列:XDCP™ 接片:256 电阻(欧姆):100k 电路数:1 温度系数:标准值 ±300 ppm/°C 存储器类型:非易失 接口:I²C(设备位址) 电源电压:2.7 V ~ 5.5 V 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:14-TSSOP(0.173",4.40mm 宽) 供应商设备封装:14-TSSOP 包装:带卷 (TR)
X9118TV14I-2.7 功能描述:IC XDCP SGL 1024TAP 100K 14TSSOP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 数字电位器 系列:XDCP™ 标准包装:2,500 系列:XDCP™ 接片:256 电阻(欧姆):100k 电路数:1 温度系数:标准值 ±300 ppm/°C 存储器类型:非易失 接口:I²C(设备位址) 电源电压:2.7 V ~ 5.5 V 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:14-TSSOP(0.173",4.40mm 宽) 供应商设备封装:14-TSSOP 包装:带卷 (TR)
X9118TV14IZ 功能描述:IC XDCP SGL 1024TAP 100K 14TSSOP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 数字电位器 系列:XDCP™ 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:- 接片:256 电阻(欧姆):100k 电路数:2 温度系数:标准值 35 ppm/°C 存储器类型:易失 接口:6 线串行(芯片选择,递增,增/减) 电源电压:2.6 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:14-TSSOP(0.173",4.40mm 宽) 供应商设备封装:14-TSSOP 包装:带卷 (TR)
X9118TV14IZ-2.7 功能描述:IC XDCP SGL 1024TAP 100K 14TSSOP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 数字电位器 系列:XDCP™ 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:- 接片:256 电阻(欧姆):100k 电路数:2 温度系数:标准值 35 ppm/°C 存储器类型:易失 接口:6 线串行(芯片选择,递增,增/减) 电源电压:2.6 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:14-TSSOP(0.173",4.40mm 宽) 供应商设备封装:14-TSSOP 包装:带卷 (TR)
X9118TV14Z 功能描述:IC XDCP SGL 1024TAP 100K 14TSSOP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 数字电位器 系列:XDCP™ 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:- 接片:256 电阻(欧姆):100k 电路数:2 温度系数:标准值 35 ppm/°C 存储器类型:易失 接口:6 线串行(芯片选择,递增,增/减) 电源电压:2.6 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:14-TSSOP(0.173",4.40mm 宽) 供应商设备封装:14-TSSOP 包装:带卷 (TR)