参数资料
型号: XR16L2752CJTR-F
厂商: Exar Corporation
文件页数: 6/49页
文件大小: 0K
描述: IC UART FIFO 64B DUAL 44PLCC
标准包装: 500
特点: *
通道数: 2,DUART
FIFO's: 64 字节
规程: RS232,RS485
电源电压: 2.25 V ~ 5.5 V
带自动流量控制功能:
带IrDA 编码器/解码器:
带故障启动位检测功能:
带调制解调器控制功能:
带CMOS:
安装类型: 表面贴装
封装/外壳: 44-LCC(J 形引线)
供应商设备封装: 44-PLCC(16.59x16.59)
包装: 带卷 (TR)
XR16L2752
xr
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.2.1
14
2.14
Auto RTS (Hardware) Flow Control
Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS#
output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control
features is enabled to fit specific application requirement (see Figure 11):
Enable auto RTS flow control using EFR bit-6.
The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
If using the Auto RTS interrupt:
Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the
RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1.
2.15
Auto RTS Hysteresis
The 2752 has a new feature that provides flow control trigger hysteresis while maintaining compatibility with
the XR16C850, ST16C650A and ST16C550 family of UARTs. With the Auto RTS function enabled, an interrupt
is generated when the receive FIFO reaches the programmed RX trigger level. The RTS# pin will not be forced
HIGH (RTS off), until the receive FIFO reaches the upper limit of the hysteresis level. The RTS# pin will return
LOW after the RX FIFO is unloaded to the lower limit of the hysteresis level. Under the above described
conditions, the 2752 will continue to accept data until the receive FIFO gets full. The Auto RTS function is
initiated when the RTS# output pin is asserted LOW (RTS On). Table 13 shows the complete details for the
Auto RTS# Hysteresis levels. Please note that this table is for programmable trigger levels only (Table D). The
hysteresis values for Tables A-C are the next higher and next lower trigger levels in Tables A-C.
2.16
Auto CTS Flow Control
Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is
monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific
application requirement (see Figure 11):
Enable auto CTS flow control using EFR bit-7.
If using the Auto CTS interrupt:
Enable CTS interrupt through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the
CTS# pin is de-asserted (HIGH): ISR bit-5 will be set to 1, and UART will suspend transmission as soon as
the stop bit of the character in process is shifted out. Transmission is resumed after the CTS# input is re-
asserted (LOW), indicating more data may be sent.
相关PDF资料
PDF描述
ST16C650AIQ48TR-F IC UART FIFO 32B 48TQFP
ST16C552ACJ68TR-F IC UART FIFO 16B DUAL 68PLCC
ST16C650ACJ44TR-F IC UART FIFO 32B 44PLCC
XR16V2552IL-F IC UART FIFO 16B DUAL 32QFN
XR16L2552IM-F IC UART FIFO 16B DUAL 48TQFP
相关代理商/技术参数
参数描述
XR16L2752IJ 制造商:EXAR 制造商全称:EXAR 功能描述:2.25V TO 5.5V DUART WITH 64-BYTE FIFO
XR16L2752IJ-F 功能描述:UART 接口集成电路 UART RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel
XR16L2752IJTR-F 制造商:Exar Corporation 功能描述:XR16L2752 Series 6.25 Mbps 5.5 V Dual UART With 64-Byte FIFO - PLCC-44
XR16L570 制造商:EXAR 制造商全称:EXAR 功能描述:SMALLEST 1.62V TO 5.5V UART WITH 16-BYTE FIFO AND POWERSAVE
XR16L570_07 制造商:EXAR 制造商全称:EXAR 功能描述:SMALLEST 1.62V TO 5.5V UART WITH 16-BYTE FIFO AND POWERSAVE