XRT86L30
56
REV. 1.0.1
SINGLE T1/E1/J1 FRAMER/LIU COMBO
1
Tx_FCS_EN
R/W
0
Transmit LAPD Message with FCS
Configure HDLC1 Controller to include/not include FCS octets in the
outbound LAPD message frames.
0 = Does not include FCS octets into the outbound LAPD message
frame.
1 = Inserts FCS octets into the outbound LAPD message frame.
NOTE: This bit-field is ignored if the transmit HDLC1 controller has
been configured to operate in the BOS mode.
0
MOS/BOS
R/W
0
Message Oriented Signaling/Bit Oriented Signaling Select
Specifies whether the TxRx HDLC1 Controller will be transmitting
and receiving LAPD message frames (MOS) or Bit Oriented Signal
(BOS) messages.
0 = Tx/Rx HDLC1 Controller transmits and receives BOS messages.
1 = Tx/Rx HDLC1 Controller transmits and receives MOS mes-
sages.
TABLE 33: TRANSMIT DATA LINK BYTE COUNT REGISTER
REGISTER 20
TRANSMIT DATA LINK BYTE COUNT REGISTER 1 (TDLBCR1)
HEX ADDRESS: 0X0114
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
BUFAVAL//BUFSEL
R/W
0
Transmit HDLC1 Buffer Available/Buffer Select
Specifies which of the two Tx HDLC1 Buffers that the Tx HDLC1
controller should read from to generate the next outbound HDLC1
message.
0 = transmits message data residing in Tx HDLC1 Buffer 0.
1 = transmits message data residing in Tx HDLC1 buffer 1.
NOTE: If one of these Tx HDLC1 buffers contain a message which
has yet to be completely read-in and processed for
transmission by the Tx HDLC1 controller, then this bit-field
will automatically reflect the value corresponding to the
available buffer. Changing this bit-field to the in-use buffer is
not permitted.
6
TDLBC6
R/W
0
Transmit HDLC1 Message - Byte Count
Depends on whether an MOS or BOS message is being transmitted
to the Remote Terminal Equipment
If BOS message is being transmitted: These bit fields contain the
number of repetitions the BOS message must be transmitted before
the Tx HDLC1 controller generates the TxEOT interrupt and halts
transmission. If these fields are set to 00000000, then the BOS mes-
sage will be transmitted for an indefinite number of times.
If MOS message is being transmitted: These bit fields contain the
length, in number of octets, of the message to be transmitted.
5
TDLBC5
R/W
0
4
TDLBC4
R/W
0
3
TDLBC3
R/W
0
2
TDLBC2
R/W
0
1
TDLBC1
R/W
0
TDLBC0
R/W
0
TABLE 32: DATA LINK CONTROL REGISTER
REGISTER 19
DATA LINK CONTROL REGISTER 1 (DLCR1)
HEX ADDRESS: 0X0113
BIT
FUNCTION
TYPE
DEFAULT