参数资料
型号: YS12S10-D
厂商: POWER-ONE INC
元件分类: 电源模块
英文描述: DC-DC REG PWR SUPPLY MODULE
封装: MODULE-6
文件页数: 25/27页
文件大小: 332K
代理商: YS12S10-D
MCD10206 Rev. 1.0, 24-Jun-10
Page 7 of 27
www.power-one.com
YS12S10 DC-DC Converter Data Sheet
9.6-14 VDC Input; 0.7525-5.5 VDC Programmable @ 10 A
Protection Features
Input Undervoltage Lockout
Input undervoltage lockout is standard with this
converter. The converter will shut down when the
input voltage drops below a pre-determined voltage;
it will start automatically when Vin returns to a
specified range.
The input voltage must be typically 9.0 V for the
converter to turn on. Once the converter has been
turned on, it will shut off when the input voltage
drops below typically 8.5 V.
Output Overcurrent Protection (OCP)
The converter is protected against overcurrent and
short circuit conditions. Upon sensing an overcurrent
condition, the converter will enter hiccup mode. Once
overload or short circuit condition is removed, Vout
will return to nominal value.
Overtemperature Protection (OTP)
The
converter
will
shut
down
under
an
overtemperature condition to protect itself from
overheating caused by operation outside the thermal
derating curves, or operation in abnormal conditions
such as system fan failure. After the converter has
cooled to a safe operating temperature, it will
automatically restart.
Safety Requirements
The
converter
meets
North
American
and
International safety regulatory requirements per
UL60950 and EN60950. The maximum DC voltage
between any two pins is Vin under all operating
conditions. Therefore, the unit has ELV (extra low
voltage) output; it meets SELV requirements under
the condition that all input voltages are ELV.
The converter is not internally fused. To comply with
safety agencies’ requirements, a recognized fuse
with a maximum rating of 15 Amps must be used in
series with the input line.
Characterization
General Information
The converter has been characterized for many
operational aspects, to include thermal derating
(maximum load current as a function of ambient
temperature and airflow) for vertical and horizontal
mountings,
efficiency,
startup
and
shutdown
parameters, output ripple and noise, transient
response to load step-change, overload, and short
circuit.
The figures are numbered as Fig. x.y, where x
indicates the different output voltages, and y
associates with specific plots (y = 1 for the vertical
thermal derating, …). For example, Fig. x.1 will refer
to the vertical thermal derating for all the output
voltages in general.
The following pages contain specific plots or
waveforms associated with the converter. Additional
comments for specific data are provided below.
Test Conditions
All data presented were taken with the converter
soldered to a test board, specifically a 0.060” thick
printed wiring board (PWB) with four layers. The top
and bottom layers were not metalized. The two inner
layers, comprised of two-ounce copper, were used to
provide traces for connectivity to the converter.
The lack of metalization on the outer layers as well
as the limited thermal connection ensured that heat
transfer from the converter to the PWB was
minimized. This provides a worst-case but consistent
scenario for thermal derating purposes.
All measurements requiring airflow were made in the
vertical and horizontal wind tunnels using Infrared
(IR)
thermography
and
thermocouples
for
thermometry.
Ensuring components on the converter do not
exceed their ratings is important to maintaining high
reliability. If one anticipates operating the converter
at or close to the maximum loads specified in the
derating curves, it is prudent to check actual
operating
temperatures
in
the
application.
Thermographic
imaging
is
preferable;
if
this
capability is not available, then thermocouples may
be used. The use of AWG #40 gauge thermocouples
is recommended to ensure measurement accuracy.
Careful routing of the thermocouple leads will further
minimize measurement error. Refer to Fig. D for the
optimum measuring thermocouple location.
Fig. D: Location of the thermocouple for thermal testing.
相关PDF资料
PDF描述
YS12S16-0G 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
YS12S16-0 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
YS12S16-DG 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
YS12S16-D 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
YSF224B-D DSP-DIGITAL FILTER, PDIP16
相关代理商/技术参数
参数描述
YS12S10-DG 功能描述:DC/DC转换器 RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
YS12S16 制造商:Power-One 功能描述:DC-DC Converter, 9.6-14 VDC In., 0.7525-5.5 VDC Programmable @ 16 A, RoHS
YS12S16-0 功能描述:DC/DC转换器 RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
YS12S16-0G 功能描述:DC/DC转换器 0.7525-5.5Vout 16A 9.6-14Vin RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
YS12S16-0G-Q 功能描述:DC/DC CONVERTER 0.7525-5.5V 88W 制造商:bel power solutions 系列:Y 包装:剪切带(CT) 零件状态:停产 类型:非隔离 PoL 模块 输出数:1 电压 - 输入(最小值):9.6V 电压 - 输入(最大值):14V 电压 - 输出 1:0.7525 ~ 5.5 V 电压 - 输出 2:- 电压 - 输出 3:- 电流 - 输出(最大值):16A 功率(W) - 制造系列:88W 电压 - 隔离:- 应用:ITE(商业) 特性:远程开/关,OCP,OTP,UVLO 安装类型:表面贴装 封装/外壳:6-SMD 模块 大小/尺寸:1.30" 长 x 0.53" 宽 x 0.33" 高(33.0mm x 13.5mm x 8.3mm) 工作温度:-40°C ~ 85°C 效率:94.8% 功率(W) - 最大值:88W 标准包装:1