参数资料
型号: ZL9101MIRZ
厂商: Intersil
文件页数: 11/19页
文件大小: 0K
描述: MODULE DGTL DC-DC 12A 21QFN
产品培训模块: Solutions for Industrial Control Applications
特色产品: ZL9101M Digital DC/DC Power Module
标准包装: 96
系列: ZL9101M
类型: 非隔离(POL)
输出数: 1
电压 - 输入(最小): 4.5V
电压 - 输入(最大): 13.2V
Voltage - Output 1: 0.6 ~ 4 V
电流 - 输出(最大): 12A
电源(瓦) - 制造商系列: 48W
安装类型: 表面贴装
封装/外壳: 21-QFN,变式
尺寸/尺寸: 0.59" L x 0.59" W x 0.14" H(15.0mm x 15.0mm x 3.5mm)
包装: 托盘
工作温度: -40°C ~ 85°C
效率: 95%
电源(瓦特)- 最大: 48W
ZL9101M
3. Continue operating for a given delay period, followed by
shutdown if the fault still exists.
4. Continue operating through the fault (this could result in
permanent damage to the power supply).
5. Initiate an immediate shutdown.
The default response from an overcurrent fault is an immediate
shutdown of the controller. The controller continuously checks for
the presence of the fault condition, and if the fault condition no
longer exists, the device is re-enabled.
Please refer to Application Note AN2033 for details on how to
select specific overcurrent fault response options via I 2 C/SMBus.
Thermal Overload Protection
The ZL9101M includes a thermal sensor that continuously
measures the internal temperature of the module and shuts
down the controller when the temperature exceeds the preset
limit. The default temperature limit is set to +125°C in the
factory, but the user may set the limit to a different value if
desired. See Application Note AN2033 for details. Note that
setting a higher thermal limit via the I 2 C/SMBus interface may
result in permanent damage to the controller. Once the module
has been disabled due to an internal temperature fault, the user
may select one of several fault response options as follows:
1. Initiate a shutdown and attempt to restart an infinite number
of times with a preset delay period between attempts.
FIGURE 13. OUTPUT RESPONSES TO PRE-BIAS VOLTAGES
If a pre-bias voltage higher than the target voltage exists after the
pre-configured delay period has expired, the target voltage is set
to match the existing pre-bias voltage, and both drivers are
enabled with a PWM duty cycle that would ideally create the
pre-bias voltage.
Once the pre-configured soft-start ramp period has expired, the
PG pin is asserted (assuming the pre-bias voltage is not higher
than the overvoltage limit). The PWM then adjusts its duty cycle
to match the original target voltage, and the output ramps down
to the preconfigured output voltage.
If a pre-bias voltage higher than the overvoltage limit exists, the
device does not initiate a turn-on sequence and declares an
overvoltage fault condition to exist. In this case, the device
responds based on the output overvoltage fault response method
that has been selected. See “Output Overvoltage Protection” on
page 10 for response options due to an overvoltage condition.
Note that pre-bias protection is not offered for current sharing
groups that also have tracking enabled. V DD must be tied to V IN
for proper prebias start-up in single module operation.
Output Overcurrent Protection
The ZL9101M can protect the power supply from damage if the
output is shorted to ground or if an overload condition is imposed
on the output. The following overcurrent protection response
options are available:
1. Initiate a shutdown and attempt to restart an infinite number
of times with a preset delay period between attempts.
2. Initiate a shutdown and attempt to restart a preset number of
times with a preset delay period between attempts.
11
2. Initiate a shutdown and attempt to restart a preset number of
times with a preset delay period between attempts.
3. Continue operating for a given delay period, followed by
shutdown if the fault still exists.
4. Continue operating through the fault (this could result in
permanent damage to the power supply).
5. Initiate an immediate shutdown.
If the user has configured the module to restart, the controller
waits the preset delay period (if configured to do so) and then
checks the module temperature. If the temperature has dropped
below a threshold that is approximately +15°C lower than the
selected temperature fault limit, the controller attempts to
re-start. If the temperature still exceeds the fault limit, the
controller waits the preset delay period and retries again.
The default response from a temperature fault is an immediate
shutdown of the module. The controller continuously checks for
the fault condition, and once the fault has cleared, the ZL9101M
is re-enabled.
Please refer to Application Note AN2033 for details on how to
select specific temperature fault response options via
I 2 C/SMBus.
I 2 C/SMBus Module Address Selection
Each module must have its own unique serial address to
distinguish between other devices on the bus. The module
address is set by connecting a resistor between the SA pin and
SGND. Table 2 lists the available module addresses.
FN7669.4
January 20, 2012
相关PDF资料
PDF描述
EBM18DRKN-S13 CONN EDGECARD 36POS .156 EXTEND
VI-B1F-CY-F1 CONVERTER MOD DC/DC 72V 50W
VI-J32-IZ CONVERTER MOD DC/DC 15V 25W
HWS30-12/A PWR SUP IND 12V 2.5A SNG OUTPUT
2211-H-RC INDUCTOR TORD HI AMP 68UH HORZ
相关代理商/技术参数
参数描述
ZL9101MIRZ-T 功能描述:DCDC DGTL PMBUS MODULE 12A 21QFN RoHS:是 类别:电源 - 板载 >> DC DC Converters 系列:ZL9101M 标准包装:10 系列:PT4570 类型:隔离 输出数:1 电压 - 输入(最小):36V 电压 - 输入(最大):75V Voltage - Output 1:9V Voltage - Output 2:- Voltage - Output 3:- 电流 - 输出(最大):3.3A 电源(瓦) - 制造商系列:30W 电压 - 隔离:1.5kV(1500V) 特点:- 安装类型:表面贴装 封装/外壳:19-SIP SMD 模块 尺寸/尺寸:3.00" L x 1.19" W x 0.50" H(76.2mm x 30.2mm x 12.7mm) 包装:托盘 工作温度:-40°C ~ 85°C 效率:84% 电源(瓦特)- 最大:30W
ZL9106MIRZ 制造商:Intersil Corporation 功能描述:- Bulk
ZL9110MIRZ 制造商:Intersil Corporation 功能描述:- Bulk
ZL9117EVAL1Z 制造商:Intersil Corporation 功能描述:ZL9117EVAL1Z EVALUATION BOARD 1 - 21LD QFN -ROHS COMPLIAN - Bulk 制造商:Intersil Corporation 功能描述:BOARD EVAL FOR ZL9117M 制造商:Intersil Corporation 功能描述:ZL9117EVAL1Z EVALUATION BOARD 1 - 21LD QFN -RoHS COMPLIAN
ZL9117M 制造商:INTERSIL 制造商全称:Intersil Corporation 功能描述:Digital DC/DC PMBus 17A Module