参数资料
型号: AD7944BCPZ
厂商: Analog Devices Inc
文件页数: 11/28页
文件大小: 0K
描述: IC ADC 14BIT 2.5MSPS 20LFCSP
标准包装: 1
系列: PulSAR®
位数: 14
采样率(每秒): 2.5M
数据接口: DSP,MICROWIRE?,QSPI?,串行,SPI?
转换器数目: 1
功率耗散(最大): 33mW
电压电源: 模拟和数字
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 20-VFQFN 裸露焊盘,CSP
供应商设备封装: 20-LFCSP-VQ
包装: 托盘
输入数目和类型: 1 个伪差分,单极
产品目录页面: 780 (CN2011-ZH PDF)
AD7944
Rev. A | Page 19 of 28
CS MODE, 3-WIRE WITHOUT BUSY INDICATOR
This mode is usually used when a single AD7944 is connected
to an SPI-compatible digital host. The connection diagram is
shown in Figure 26, and the corresponding timing is given in
With SDI tied to VIO, a rising edge on CNV initiates a con-
version, selects CS mode, and forces SDO to high impedance.
When a conversion is initiated, it continues until completion,
irrespective of the state of CNV. This can be useful, for example,
to bring CNV low to select other SPI devices, such as analog
multiplexers; however, CNV must be returned high before the
minimum conversion time elapses and then held high for the
maximum possible conversion time to avoid the generation of
the busy signal indicator.
When the conversion is complete, the AD7944 enters the
acquisition phase and, if the part is in normal mode (TURBO
low), powers down. When CNV goes low, the MSB is output
onto SDO. The remaining data bits are clocked by subsequent
SCK falling edges. The data is valid on both SCK edges. Although
the rising edge can be used to capture the data, a digital host
using the SCK falling edge allows a faster reading rate, provided
that it has an acceptable hold time. After the 14th SCK falling
edge or when CNV goes high (whichever occurs first), SDO
returns to high impedance.
AD7944
SDI
SDO
CNV
SCK
CONVERT
DATA IN
CLK
DIGITAL HOST
VIO
04658-
009
Figure 26. CS Mode, 3-Wire Without Busy Indicator Connection Diagram (SDI High)
ACQUISITION (n)
ACQUISITION
(n + 1)
ACQUISITION
(n – 1)
1
2
BEGIN DATA (n – 1)
CONVERSION (n)
END DATA (n – 1)
SCK
CNV
SDO
12
13
CONVERSION (n – 1)
END DATA (n – 2)
tCONV
tDATA
0
(I/O QUIET
TIME)
(I/O QUIET
TIME)
14
12
13
14
1
13
12
11
2
0
1
2
SDI = 1
>
tCONV
(I/O QUIET
TIME)
tCYC
tACQ
tCNVH
tQUIET
tSCK
tDIS
tEN
tDSDO
tHSDO
tDATA
tCONV
04658-
010
Figure 27. CS Mode, 3-Wire Without Busy Indicator Serial Interface Timing (SDI High)
相关PDF资料
PDF描述
AD7946BCPZRL7 IC ADC 14BIT 500KSPS 10-LFCSP
AD7948BN IC DAC 12BIT MULT PARALL 20-DIP
AD7949BCPZRL7 IC ADC 14BIT 250KSPS 8CH 20LFCSP
AD7951BSTZRL IC ADC 14BIT 1MSPS 48-LQFP
AD7952BCPZ IC ADC 14BIT DIFF 1MSPS 48LFCSP
相关代理商/技术参数
参数描述
AD7944BCPZ-RL7 功能描述:IC ADC 14B 2.5MSPS PULSR 20LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:PulSAR® 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极
AD7945 制造商:AD 制造商全称:Analog Devices 功能描述:+3.3 V/+5 V Multiplying 12-Bit DACs
AD7945AN-B 功能描述:IC DAC 12BIT MULT PARALL 20-DIP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 数模转换器 系列:- 标准包装:2,400 系列:- 设置时间:- 位数:18 数据接口:串行 转换器数目:3 电压电源:模拟和数字 功率耗散(最大):- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:36-TFBGA 供应商设备封装:36-TFBGA 包装:带卷 (TR) 输出数目和类型:* 采样率(每秒):*
AD7945ANZ-B 功能描述:IC DAC 12BIT MULT PARALL 20DIP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 数模转换器 系列:- 标准包装:47 系列:- 设置时间:2µs 位数:14 数据接口:并联 转换器数目:1 电压电源:单电源 功率耗散(最大):55µW 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:28-SSOP(0.209",5.30mm 宽) 供应商设备封装:28-SSOP 包装:管件 输出数目和类型:1 电流,单极;1 电流,双极 采样率(每秒):*
AD7945ARS-B 功能描述:IC DAC 12BIT MULT PARALL 20-SSOP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 数模转换器 系列:- 标准包装:47 系列:- 设置时间:2µs 位数:14 数据接口:并联 转换器数目:1 电压电源:单电源 功率耗散(最大):55µW 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:28-SSOP(0.209",5.30mm 宽) 供应商设备封装:28-SSOP 包装:管件 输出数目和类型:1 电流,单极;1 电流,双极 采样率(每秒):*