参数资料
型号: AD7944BCPZ
厂商: Analog Devices Inc
文件页数: 15/28页
文件大小: 0K
描述: IC ADC 14BIT 2.5MSPS 20LFCSP
标准包装: 1
系列: PulSAR®
位数: 14
采样率(每秒): 2.5M
数据接口: DSP,MICROWIRE?,QSPI?,串行,SPI?
转换器数目: 1
功率耗散(最大): 33mW
电压电源: 模拟和数字
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 20-VFQFN 裸露焊盘,CSP
供应商设备封装: 20-LFCSP-VQ
包装: 托盘
输入数目和类型: 1 个伪差分,单极
产品目录页面: 780 (CN2011-ZH PDF)
AD7944
Rev. A | Page 22 of 28
CS MODE, 4-WIRE WITH BUSY INDICATOR
This mode is usually used when a single AD7944 is connected
to an SPI-compatible digital host with an interrupt input and
when it is desired to keep CNV, which is used to sample the
analog input, independent of the signal used to select the data
reading. This independence is particularly important in applica-
tions where low jitter on CNV is desired. This mode is available
only in normal conversion mode (TURBO low). The connection
diagram is shown in Figure 32, and the corresponding timing is
With SDI high, a rising edge on CNV initiates a conversion,
selects CS mode, and forces SDO to high impedance. In this
mode, CNV must be held high during the conversion phase and
the subsequent data readback. (If SDI and CNV are low, SDO is
driven low.) Prior to the minimum conversion time, SDI can be
used to select other SPI devices, such as analog multiplexers, but
SDI must be returned low before the minimum conversion time
elapses and then held low for the maximum possible conversion
time to guarantee the generation of the busy signal indicator.
When the conversion is complete, SDO goes from high imped-
ance to low impedance. With a pull-up on the SDO line, this
transition can be used as an interrupt signal to initiate the data
readback controlled by the digital host. The AD7944 then enters
the acquisition phase and powers down. The data bits are then
clocked out, MSB first, by subsequent SCK falling edges. The
data is valid on both SCK edges. Although the rising edge can
be used to capture the data, a digital host using the SCK falling
edge allows a faster reading rate, provided that it has an accept-
able hold time. After the optional 15th SCK falling edge or when
SDI goes high (whichever occurs first), SDO returns to high
impedance.
AD7944
SDI
SDO
CNV
SCK
CONVERT
DATA IN
CLK
DIGITAL HOST
IRQ
VIO
47k
CS1
TURBO
04658-
015
Figure 32. CS Mode, 4-Wire with Busy Indicator Connection Diagram
(I/O QUIET
TIME)
SDO
D13
D12
D1
D0
tDIS
tQUIET
SCK
1
2
3
13
14
15
tSCK
tSCKL
tSCKH
tHSDO
tDSDO
tEN
CONVERSION
ACQUISITION
tCONV
tCYC
tACQ
ACQUISITION
SDI
CNV
tSSDICNV
tHSDICNV
TURBO = 0
04658-
016
Figure 33. CS Mode, 4-Wire with Busy Indicator Serial Interface Timing
相关PDF资料
PDF描述
AD7946BCPZRL7 IC ADC 14BIT 500KSPS 10-LFCSP
AD7948BN IC DAC 12BIT MULT PARALL 20-DIP
AD7949BCPZRL7 IC ADC 14BIT 250KSPS 8CH 20LFCSP
AD7951BSTZRL IC ADC 14BIT 1MSPS 48-LQFP
AD7952BCPZ IC ADC 14BIT DIFF 1MSPS 48LFCSP
相关代理商/技术参数
参数描述
AD7944BCPZ-RL7 功能描述:IC ADC 14B 2.5MSPS PULSR 20LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:PulSAR® 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极
AD7945 制造商:AD 制造商全称:Analog Devices 功能描述:+3.3 V/+5 V Multiplying 12-Bit DACs
AD7945AN-B 功能描述:IC DAC 12BIT MULT PARALL 20-DIP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 数模转换器 系列:- 标准包装:2,400 系列:- 设置时间:- 位数:18 数据接口:串行 转换器数目:3 电压电源:模拟和数字 功率耗散(最大):- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:36-TFBGA 供应商设备封装:36-TFBGA 包装:带卷 (TR) 输出数目和类型:* 采样率(每秒):*
AD7945ANZ-B 功能描述:IC DAC 12BIT MULT PARALL 20DIP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 数模转换器 系列:- 标准包装:47 系列:- 设置时间:2µs 位数:14 数据接口:并联 转换器数目:1 电压电源:单电源 功率耗散(最大):55µW 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:28-SSOP(0.209",5.30mm 宽) 供应商设备封装:28-SSOP 包装:管件 输出数目和类型:1 电流,单极;1 电流,双极 采样率(每秒):*
AD7945ARS-B 功能描述:IC DAC 12BIT MULT PARALL 20-SSOP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 数模转换器 系列:- 标准包装:47 系列:- 设置时间:2µs 位数:14 数据接口:并联 转换器数目:1 电压电源:单电源 功率耗散(最大):55µW 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:28-SSOP(0.209",5.30mm 宽) 供应商设备封装:28-SSOP 包装:管件 输出数目和类型:1 电流,单极;1 电流,双极 采样率(每秒):*