Chain Mode, No BUSY Indicator
This mode can be used to daisy chain multiple AD7946s on a 3-
wire serial interface. This feature is useful for reducing
component count and wiring connections, e.g., in isolated
multiconverter applications or for systems with a limited
interfacing capacity. Data readback is analogous to clocking a
shift register.
A connection diagram example using two AD7946s is shown in
Figure 37 and the corresponding timing is given in Figure 38.
When SDI and CNV are low, SDO is driven low. With SCK low,
a rising edge on CNV initiates a conversion, selects the chain
mode, and disables the BUSY indicator. In this mode, CNV is
held high during the conversion phase and the subsequent data
readback. When the conversion is complete, the MSB is output
onto SDO and the AD7946 enters the acquisition phase and
powers down. The remaining data bits stored in the internal
shift register are then clocked by subsequent SCK falling edges.
For each ADC, SDI feeds the input of the internal shift register
and is clocked by the SCK falling edge. Each ADC in the chain
outputs its data MSB first, and 14 × N clocks are required to
readback the N ADCs. The data is valid on both SCK edges.
Although the rising edge can be used to capture the data, a
digital host also using the SCK falling edge will allow a faster
reading rate and, consequently more AD7946s in the chain,
provided the digital host has an acceptable hold time. The
maximum conversion rate may be reduced due to the total
readback time. For instance, with a 5 ns digital host set-up time
and 3 V interface, up to five AD7946s running at a conversion
rate of 333 kSPS can be daisy-chained on a 3-wire port.
CNV
SCK
SDO
SDI
CLK
CONVERT
DATA IN
DIGITAL HOST
AD7946
B
CNV
SCK
SDO
SDI
AD7946
A
Figure 37. Chain Mode, No BUSY Indicator Connection Diagram
04656-P
rC-016
SDOA = SDIB
DA13
DA12
DA11
SCK
12
3
26
27
28
tSSDISCK
tHSDISC
tEN
CONVERSION
ACQUISITION
tCONV
tCYC
tACQ
ACQUISITION
CNV
DA1
12
13
tSCK
tSCKL
tSCKH
DA0
15
16
14
SDIA = 0
SDOB
DB13
DB12
DB11
DA1
DB1DB0DA13
DA12
tHSDO
tDSDO
tSSCKCNV
tHSCKCNV
DA0
Figure 38. Chain Mode, No BUSY Indicator Serial Interface Timing
相关PDF资料
PDF描述
AD8138-EVAL Low Distortion Differential ADC Driver
AD8138AR Low Distortion Differential ADC Driver
AD8139ACP-REEL Low Noise Rail-to-Rail Differential ADC Driver
AD8139ACP-REEL7 Low Noise Rail-to-Rail Differential ADC Driver
AD8139ACPZ-REEL7 Low Noise Rail-to-Rail Differential ADC Driver
相关代理商/技术参数
参数描述
AD79461 制造商:AD 制造商全称:Analog Devices 功能描述:18-Bit, 2 MSPS PulSAR 15 mW ADC in LFCSP (QFN)
AD7946BCP 制造商:Analog Devices 功能描述:ADC SGL SAR 500KSPS 14BIT SERL 10LFCSP EP - Bulk
AD7946BCPRL7 制造商:AD 制造商全称:Analog Devices 功能描述:14-Bit, 500 kSPS PulSAR⑩ ADC in MSOP/QFN
AD7946BCPWP 制造商:AD 制造商全称:Analog Devices 功能描述:14-Bit, 500 kSPS PulSAR⑩ ADC in MSOP/QFN
AD7946BCPZRL 功能描述:IC ADC 14BIT 500KSPS 10-LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:PulSAR® 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极