DS26324 3.3V, 16-Channel, E1/T1/J1 Short-Haul Line Interface Unit
73 of 120
Register Name:
RSMM4
Register Description:
Receive Sensitivity Monitor Mode 4
Register Address (LIUs 1–8):
0Bh
Bit #
7
6
5
4
3
2
1
0
Name
RTR8
C8RSM2
C8RSM1
C8RSM0
RTR7
C7RSM2
C7RSM1
C7RSM0
Default
0
Bit 7: Receiver Transformer Turns Ratio Channel 8 (RTR8). If this bit is set the turns ratio is 1:1 on the receiver
side. This bit should be set when a 1:1 receiver transformer is used. Note that in order to use fully internal receive
impedance termination, a 1:1 transformer must be used and this bit must be set to 1.
Bits 6 to 4: Channel 8 Receive Sensitivity/Monitor Select [2:0] (C8RSM[2:0]). Bits C8RSM[2:0] are used to
select the receiver sensitivity level and the monitor mode resistive gain. See
Table 6-16.Bit 3: Receiver Transformer Turns Ratio Channel 7 (RTR7). If this bit is set the turns ratio is 1:1 on the receiver
side. This bit should be set when a 1:1 receiver transformer is used. Note that in order to use the fully internal
receive impedance termination, a 1:1 transformer must be used and this bit must be set to 1.
Bits 2 to 0: Channel 7 Receive Sensitivity/Monitor Select [2:0] (C7RSM[2:0]). Bits C7RSM[2:0] are used to
select the receiver sensitivity level and the monitor mode resistive gain. See
Table 6-16.Register Address (LIUs 9–16):
2Bh
Bit #
7
6
5
4
3
2
1
0
Name
RTR16
C16RSM2
C16RSM1
C16RSM0
RTR15
C15RSM2
C15RSM1
C15RSM0
Default
0
Bit 7: Receiver Transformer Turns Ratio Channel 16 (RTR16). If this bit is set the turns ratio is 1:1 on the
receiver side. This bit should be set when a 1:1 receiver transformer is used. Note that in order to use fully internal
receive impedance termination, a 1:1 transformer must be used and this bit must be set to 1.
Bit 6 to 4: Channel 16 Receive Sensitivity/Monitor Select [2:0] (C16RSM[2:0]). Bits C16RSM[2:0] are used to
select the receiver sensitivity level and the monitor mode resistive gain. See
Table 6-16.Bit 3: Receiver Transformer Turns Ratio Channel 15 (RTR15). If this bit is set the turns ratio is 1:1 on the
receiver side. This bit should be set when a 1:1 receiver transformer is used. Note that in order to use the fully
internal receive impedance termination, a 1:1 transformer must be used and this bit must be set to 1.
Bits 2 to 0: Channel 15 Receive Sensitivity/Monitor Select [2:0] (C15RSM[2:0]). Bits C15RSM[2:0] are used to
select the receiver sensitivity level and the monitor mode resistive gain. See
Table 6-16.Table 6-16. Receiver Sensitivity/Monitor Mode Gain Selection
RECEIVER
MONITOR
MODE
DISABLED
CnRSM[2:0],
T1/ E1 MODE
RECEIVER
SENSITIVITY
(MAXIMUM
LOSS)
(dB)
RECEIVER
MONITOR
MODE GAIN
SETTINGS
(dB)
LOSS
DECLARATION
LEVEL
(dB)
No flat gain
000
12
0
15
No flat gain
001
18
0
21
Receiver
monitor mode
enabled
CnRSM[2:0]
Max cable loss
Receiver
monitor mode
gain settings
—
Flat gain
100
30
14
37
Flat gain
101
22.5
20
45.5