ADE7953
Interrupt Enable and Interrupt Status Registers
Current Channel A and Voltage Channel Registers
Table 22. IRQENA Register (Address 0x22C and Address 0x32C)
Data Sheet
Bits
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Bit Name
AEHFA
VAREHFA
VAEHFA
AEOFA
VAREOFA
VAEOFA
AP_NOLOADA
VAR_NOLOADA
VA_NOLOADA
APSIGN_A
VARSIGN_A
ZXTO_IA
ZXIA
OIA
ZXTO
ZXV
OV
WSMP
CYCEND
Sag
Reset
CRC
Description
Set to 1 to enable an interrupt when the active energy is half full (Current Channel A)
Set to 1 to enable an interrupt when the reactive energy is half full (Current Channel A)
Set to 1 to enable an interrupt when the apparent energy is half full (Current Channel A)
Set to 1 to enable an interrupt when the active energy has overflowed or underflowed (Current Channel A)
Set to 1 to enable an interrupt when the reactive energy has overflowed or underflowed (Current Channel A)
Set to 1 to enable an interrupt when the apparent energy has overflowed or underflowed (Current Channel A)
Set to 1 to enable an interrupt when the active power no-load condition is detected on Current Channel A
Set to 1 to enable an interrupt when the reactive power no-load condition is detected on Current Channel A
Set to 1 to enable an interrupt when the apparent power no-load condition is detected on Current Channel A
Set to 1 to enable an interrupt when the sign of active energy has changed (Current Channel A)
Set to 1 to enable an interrupt when the sign of reactive energy has changed (Current Channel A)
Set to 1 to enable an interrupt when the zero crossing has been missing on Current Channel A for the length of
time specified in the ZXTOUT register
Set to 1 to enable an interrupt when the current Channel A zero crossing occurs
Set to 1 to enable an interrupt when the current Channel A peak has exceeded the overcurrent threshold set in the
OILVL register
Set to 1 to enable an interrupt when a zero crossing has been missing on the voltage channel for the length of
time specified in the ZXTOUT register
Set to 1 to enable an interrupt when the voltage channel zero crossing occurs
Set to 1 to enable an interrupt when the voltage peak has exceeded the overvoltage threshold set in the OVLVL
register
Set to 1 to enable an interrupt when new waveform data is acquired
Set to 1 to enable an interrupt when it is the end of a line cycle accumulation period
Set to 1 to enable an interrupt when a sag event has occurred
This interrupt is always enabled and cannot be disabled
Set to 1 to enable an interrupt when the checksum has changed
Table 23. IRQSTATA Register (Address 0x22D and Address 0x32D) and RSTIRQSTATA Register (Address 0x22E and
Address 0x32E)
Bits
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Bit Name
AEHFA
VAREHFA
VAEHFA
AEOFA
VAREOFA
VAEOFA
AP_NOLOADA
VAR_NOLOADA
VA_NOLOADA
APSIGN_A
VARSIGN_A
ZXTO_IA
ZXIA
OIA
ZXTO
ZXV
OV
Description
Set to 1 when the active energy register is half full (Current Channel A)
Set to 1 when the reactive energy register is half full (Current Channel A)
Set to 1 when the apparent energy register is half full (Current Channel A)
Set to 1 when the active energy register has overflowed or underflowed (Current Channel A)
Set to 1 when the reactive energy register has overflowed or underflowed (Current Channel A)
Set to 1 when the apparent energy register has overflowed or underflowed (Current Channel A)
Set to 1 when the active power no-load condition is detected Current Channel A
Set to 1 when the reactive power no-load condition is detected Current Channel A
Set to 1 when the apparent power no-load condition is detected Current Channel A
Set to 1 when the sign of active energy has changed (Current Channel A)
Set to 1 when the sign of reactive energy has changed (Current Channel A)
Set to 1 when a zero crossing has been missing on Current Channel A for the length of time specified in the
ZXTOUT register
Set to 1 when a current Channel A zero crossing is detected
Set to 1 when the current Channel A peak has exceeded the overcurrent threshold set in the OILVL register
Set to 1 when a zero crossing has been missing on the voltage channel for the length of time specified in the
ZXTOUT register
Set to 1 when the voltage channel zero crossing is detected
Set to 1 when the voltage peak has exceeded the overvoltage threshold set in the OVLVL register
Rev. B | Page 66 of 72
相关PDF资料
PDF描述
EVAL-ADF4002EBZ1 BOARD EVAL FOR ADF4002
EVAL-ADG788EBZ BOARD EVALUATION FOR ADG788
EVAL-ADM1021AEB BOARD EVAL FOR ADM1021
EVAL-ADM1023EB BOARD EVAL FOR ADM1023
EVAL-ADM1031EB BOARD EVAL FOR ADM1031
相关代理商/技术参数
参数描述
EVAL-ADF4001EBZ2 制造商:Analog Devices 功能描述:Evaluation Board For Pll Frequency Synthesizer 制造商:Analog Devices 功能描述:ADF4001 PLL SYNTHESIZER EVAL BOARD
EVAL-ADF4002EB1 制造商:Analog Devices 功能描述:EVAL BOARD - Bulk
EVAL-ADF4002EBZ1 功能描述:BOARD EVAL FOR ADF4002 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- 主要目的:电源管理,电池充电器 嵌入式:否 已用 IC / 零件:MAX8903A 主要属性:1 芯锂离子电池 次要属性:状态 LED 已供物品:板
EVAL-ADF4007EBZ1 功能描述:BOARD EVALUATION FOR ADF4007EB1 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:PSoC® 主要目的:电源管理,热管理 嵌入式:- 已用 IC / 零件:- 主要属性:- 次要属性:- 已供物品:板,CD,电源
EVAL-ADF4106EB1 制造商:Analog Devices 功能描述:PLL, Frequency Synthesizer