参数资料
型号: EVAL-ADF4113EBZ1
厂商: Analog Devices Inc
文件页数: 13/28页
文件大小: 0K
描述: BOARD EVAL FOR ADF4113
标准包装: 1
主要目的: 计时,频率合成器
嵌入式:
已用 IC / 零件: ADF4113
主要属性: 单路整数-N PLL
次要属性: 1.75GHz 图形用户界面
已供物品: 板,线缆,软件
相关产品: ADF4113BCPZ-ND - IC PLL FREQ SYNTHESIZER 20-LFCSP
ADF4113BCPZ-RL7-ND - IC PLL FREQ SYNTHESIZER 20-LFCSP
ADF4113BCPZ-RL-ND - IC PLL FREQ SYNTHESIZER 20-LFCSP
ADF4113HVBRUZ-RL7-ND - IC CHARGE PUMP HV SYNTH 16-TSSOP
ADF4113HVBRUZ-RL-ND - IC CHARGE PUMP HV SYNTH 16-TSSOP
ADF4113HVBCPZ-RL7-ND - IC CHARGE PUMP HV SYNTH 20-LFCSP
ADF4113HVBCPZ-RL-ND - IC CHARGE PUMP HV SYNTH 20-LFCSP
ADF4113HVBRUZ-ND - IC CHARGE PUMP HV SYNTH 16-TSSOP
ADF4113HVBCPZ-ND - IC CHARGE PUMP HV SYNTH 20-LFCSP
ADF4113BRUZ-REEL7TR-ND - IC SYNTHESZR FREQ PLL RF 16TSSOP
更多...
ADF4110/ADF4111/ADF4112/ADF4113
Data Sheet
Rev. F | Page 20 of 28
Note that there is an enable feature on the timer counter. It is
enabled when Fastlock Mode 2 is chosen by setting the fastlock
mode bit (DB10) in the function latch to 1.
Charge Pump Currents
CPI3, CPI2, and CPI1 program Current Setting 1 for the charge
pump. CPI6, CPI5, and CPI4 program Current Setting 2 for the
charge pump. The truth table is given in Table 10.
Prescaler Value
P2 and P1 in the function latch set the prescaler values. The
prescaler value should be chosen so that the prescaler output
frequency is always less than or equal to 200 MHz. Thus, with
an RF frequency of 2 GHz, a prescaler value of 16/17 is valid but
a value of 8/9 is not.
PD Polarity
This bit sets the phase detector polarity bit. See Table 10.
CP Three-State
This bit controls the CP output pin. With the bit set high, the
CP output is put into three-state. With the bit set low, the CP
output is enabled.
INITIALIZATION LATCH
When C2, C1 = 1, 1, the initialization latch is programmed.
This is essentially the same as the function latch (programmed
when C2, C1 = 1, 0).
However, when the initialization latch is programmed, an addi-
tional internal reset pulse is applied to the R and AB counters.
This pulse ensures that the AB counter is at load point when the
AB counter data is latched, and the device begins counting in
close phase alignment.
If the latch is programmed for synchronous power-down (CE
pin high; PD1 bit high; PD2 bit low), the internal pulse also
triggers this power-down. The prescaler reference and the
oscillator input buffer are unaffected by the internal reset pulse,
so close phase alignment is maintained when counting resumes.
When the first AB counter data is latched after initialization, the
internal reset pulse is again activated. However, successive AB
counter loads after this will not trigger the internal reset pulse.
DEVICE PROGRAMMING AFTER INITIAL
POWER-UP
After initial power-up of the device, there are three ways to
program the device.
Initialization Latch Method
Apply VDD. Program the initialization latch (11 in 2 LSBs of
input word). Make sure the F1 bit is programmed to 0. Then, do
an R load (00 in 2 LSBs). Then do an AB load (01 in 2 LSBs).
When the initialization latch is loaded, the following occurs:
1. The function latch contents are loaded.
2. An internal pulse resets the R, A, B, and timeout counters
to load state conditions and three-states the charge pump.
Note that the prescaler band gap reference and the oscil-
lator input buffer are unaffected by the internal reset pulse,
allowing close phase alignment when counting resumes.
3. Latching the first AB counter data after the initialization
word activates the same internal reset pulse. Successive AB
loads do not trigger the internal reset pulse unless there is
another initialization.
CE Pin Method
1. Apply VDD.
2. Bring CE low to put the device into power-down. This is an
asynchronous power-down in that it happens immediately.
3. Program the function latch (10). Program the R counter
latch (00). Program the AB counter latch (01).
4. Bring CE high to take the device out of power-down. The R
and AB counters now resume counting in close alignment.
After CE goes high, a duration of 1 s may be required for the
prescaler band gap voltage and oscillator input buffer bias to
reach steady state.
CE can be used to power the device up and down in order to
check for channel activity. The input register does not need to
be reprogrammed each time the device is disabled and enabled
as long as it has been programmed at least once after VDD was
initially applied.
Counter Reset Method
1. Apply VDD.
2. Do a function latch load (10 in 2 LSBs). As part of this,
load 1 to the F1 bit. This enables the counter reset.
3. Do an R counter load (00 in 2 LSBs). Do an AB counter
load (01 in 2 LSBs). Do a function latch load (10 in 2
LSBs). As part of this, load 0 to the F1 bit. This disables the
counter reset.
This sequence provides the same close alignment as the initiali-
zation method. It offers direct control over the internal reset.
Note that counter reset holds the counters at load point and
three states the charge pump but does not trigger synchronous
power-down. The counter reset method requires an extra
function latch load compared to the initialization latch method.
相关PDF资料
PDF描述
EBM31DCBN CONN EDGECARD 62POS R/A .156 SLD
EBM31DCBH CONN EDGECARD 62POS R/A .156 SLD
ECE-T2GA681FA CAP ALUM 680UF 400V 20% SNAP
EBM31DCBD CONN EDGECARD 62POS R/A .156 SLD
EBM31DCAN CONN EDGECARD 62POS R/A .156 SLD
相关代理商/技术参数
参数描述
EVAL-ADF4113EBZ2 功能描述:BOARD EVAL FOR ADF4113 1750MHZ RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:PSoC® 主要目的:电源管理,热管理 嵌入式:- 已用 IC / 零件:- 主要属性:- 次要属性:- 已供物品:板,CD,电源
EVAL-ADF4113HVEB1Z 功能描述:BOARD EVALUATION FOR ADF4113HV RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:- 主要目的:电信,线路接口单元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要属性:T1/J1/E1 LIU 次要属性:- 已供物品:板,电源,线缆,CD 其它名称:82EBV2081
EVAL-ADF4118EB1 制造商:AD 制造商全称:Analog Devices 功能描述:WCDMA Evaluation Board For PLL Frequency Synthesizer
EVAL-ADF4118EBZ1 功能描述:BOARD EVAL FOR ADF4118 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:- 主要目的:电信,线路接口单元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要属性:T1/J1/E1 LIU 次要属性:- 已供物品:板,电源,线缆,CD 其它名称:82EBV2081
EVAL-ADF4118EBZ11 制造商:AD 制造商全称:Analog Devices 功能描述:RF PLL Frequency Synthesizers