位数: 18
采样率(每秒): 480
数据接口: QSPI?,串行,SPI?
转换器数目: 1
功率耗散(最大): 1.25mW
电压电源: 模拟和数字
工作温度: 0°C ~ 70°C
安装类型: 表面贴装
封装/外壳: 28-SSOP(0.209",5.30mm 宽)
供应商设备封装: 28-SSOP
包装: 管件
输入数目和类型: 3 个差分,单极;3 个差分,双极;5 个伪差分,单极;5 个伪差分,双极
MAX1400
+5V, 18-Bit, Low-Power, Multichannel,
Oversampling (Sigma-Delta) ADC
______________________________________________________________________________________
13
Selecting Clock Polarity
The serial interface can be operated with the clock
idling either high or low. This is compatible with
Motorola’s SPI interface operated in (CPOL = 1, CPHA
= 1) or (CPOL = 0, CPHA = 1) mode. Select the clock
polarity by sampling the state of SCLK at the falling
edge of CS. Ensure that the setup times t4/t12 and t5/t13
are not violated. If CS is connected to ground, resulting
in no falling edge on CS, SCLK must idle high (CPOL =
1, CPHA = 1).
Data-Ready Signal (DRDY bit true or IIN
NTT = low)
The data-ready signal indicates that new data may be
read from the 24-bit data register. After the end of a suc-
cessful data register read, the data-ready signal
becomes false. If a new measurement completes before
the data is read, the data-ready signal becomes false.
The data-ready signal becomes true again when new
data is available in the data register.
The MAX1400 provides two methods of monitoring the
data-ready signal. INT provides a hardware solution
(active low when data is ready to be accessed), while
the DRDY bit in the COMM register provides a software
solution (active high).
Read data as soon as possible once data-ready
becomes true. This becomes increasingly important for
faster measurement rates. If the data-read is delayed
significantly, a collision may result. A collision occurs
when a new measurement completes during a data-
register read operation. After a collision, information in
the data register is invalid. The failed read operation
must be completed even though the data is invalid.
Resetting the Interface
Reset the serial interface by clocking in 32 1s.
Resetting the interface does not affect the internal reg-
isters.
If continuous data output mode is in use, clock in eight
0s followed by 32 1s. More than 32 1s may be clocked
in, since a leading 0 is used as the start bit for all oper-
ations.
Continuous Data Output Mode
When scanning the input channels (SCAN = 1), the ser-
ial interface allows the data register to be read repeat-
edly without requiring a write to the COMM register.
The initial COMM write (01111000) is followed by 24
clocks (DIN = high) to read the 24-bit data register.
Once the data register has been read, it can be read
again after the next conversion by writing another 24
clocks (DIN = high). Terminate the continuous data out-
put mode by writing to the COMM register with any
valid access.
Modulator Data Output (MDOUT = 1)
Single-bit, raw modulator data is available at DOUT for
custom filtering when MDOUT = 1. INT provides a mod-
ulator clock for data synchronization. Data is valid on
the falling edge of INT. Write operations can still be
performed, however, read operations are disabled.
After MDOUT is returned to 0, valid data is accessed
by the normal serial-interface read operation.
On-Chip Registers
Communications Register
0/DRDY: (Default = 0) Data Ready Bit. On a write, this
bit must be reset to 0 to signal the start of the Com-
munications Register data word. On a read, a 1 in this
location (0/DRDY) signifies that valid data is available in
the data register. This bit is reset after the data register
is read or, if data is not read, 0/DRDY will go low at the
end of the next measurement.
RS2, RS1, RS0: (Default = 0, 0, 0) Register Select
Bits. These bits select the register to be accessed
(Table 1).
R/W: (Default = 0) Read/Write Bit. When set high, the
selected register is read; when R/W = 0, the selected
register is written.
RESET: (Default = 0) Software Reset Bit. Setting this
bit high causes the part to be reset to its default power-
up condition (RESET = 0).
STDBY: (Default = 0) Standby Power-Down Bit. Setting
the STDBY bit places the part in “standby” condition,
shutting down everything except the serial interface
and the CLK oscillator.
First Bit (MSB)
(LSB)
FUNCTION
0
STDBY
0
RESET
0
Name
FSYNC
0
REGISTER SELECT BITS
RS0
0
RS1
0
DATA RDY
Defaults
RS2
0
R/W
0/DRDY
Communications Register
相关PDF资料
PDF描述
MAX1401CAI+ IC ADC 18BIT LP 28-SSOP
MAX1415AEWE+T IC ADC 16BIT DELTA SIGMA 16-SOIC
MAX1421CCM+D IC ADC 12BIT 40MSPS 48LQFP
MAX1426EAI+T IC ADC 10BITS 10MSPS 28SSOP
MAX1434ECQ+D IC ADC 10BIT 50MSPS 100-TQFP
相关代理商/技术参数
参数描述
MAX1400CAI+ 功能描述:模数转换器 - ADC 18-Bit 5Ch 4.8ksps 2.5V Precision ADC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MAX1400CAI+T 功能描述:模数转换器 - ADC 18-Bit 5Ch 4.8ksps 2.5V Precision ADC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MAX1400CAI+W 制造商:Maxim Integrated Products 功能描述:
MAX1400CAI-T 功能描述:模数转换器 - ADC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MAX1400EAI 功能描述:模数转换器 - ADC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32