Analog Integrated Circuit Device Data
60
Freescale Semiconductor
33903/4/5
CAN INTERFACE
CAN BUS FAULT DIAGNOSTIC
Once the error is detected the driver is disabled and the
error is reported via SPI in CAN register.
Recovery Condition
The internal recovery is done by sampling a correct low
level at TXD as shown in the following illustration.
Figure 40. RXD Path Simplified Schematic, RXD Short to VDD Detection
TXD PERMANENT DOMINANT
Principle
If the TXD is set to a permanent low level, the CAN bus is
set into dominant level, and no communication is possible.
The device has a TXD permanent timeout detector. After the
timeout (TDOUT), the bus driver is disabled and the bus is
released into a recessive state. The TXD permanent flag is
set.
Recovery
The TXD permanent dominant is used and activated when
there is a TXD short to RXD. The recovery condition for a
TXD permanent dominant (recovery means the re-activation
of the CAN drivers) is done by entering into a Normal mode
controlled by the MCU or when TXD is recessive while RXD
change from recessive to dominant.
TXD TO RXD SHORT-CIRCUIT
Principle
When TXD is shorted to RXD during incoming dominant
information, RXD is set to low. Consequently, the TXD pin is
low and drives CANH and CANL into a dominant state. Thus
the bus is stuck in dominant. No further communication is
possible.
Detection and Recovery
The TXD permanent dominant timeout will be activated and
release the CANL and CANH drivers. However, at the next
incoming dominant bit, the bus will then be stuck in dominant
again. The recovery condition is same as the TXD dominant
failure
IMPORTANT INFORMATION FOR BUS DRIVER
REACTIVATION
The driver stays disabled until the failure is/are removed
(TXD and/or RXD is no longer permanent dominant or
recessive state or shorted) and the failure flags cleared
(read). The CAN driver must be set by SPI in TXD/RXD mode
in order to re enable the CAN bus driver.
CANL&H
Diff output
RXD output
RXD short to VDD
RXD flag
RXD flag latched
Sampling
The RXD flag is not the RXPR bit in the LPC register, and neither is the CANF in the INTR register.
RXD no longer shorted to VDD
相关PDF资料
PDF描述
VE-B50-IW-F4 CONVERTER MOD DC/DC 5V 100W
D38999/24MD15HN CONN RCPT 15POS JAM NUT W/PINS
MCZ33903B3EKR2 IC SBC CAN HS 3.3V 32SOIC
VE-J4B-IW-F4 CONVERTER MOD DC/DC 95V 100W
VE-B4W-IW-F4 CONVERTER MOD DC/DC 5.5V 100W
相关代理商/技术参数
参数描述
MCZ33903B5EKR2 功能描述:CAN 接口集成电路 SBC W/HIGH SPEED CAN 5V RoHS:否 制造商:Texas Instruments 类型:Transceivers 工作电源电压:5 V 电源电流: 工作温度范围:- 40 C to + 85 C 封装 / 箱体:SOIC-8 封装:Tube
MCZ33903B5R2 制造商:FREESCALE 制造商全称:Freescale Semiconductor, Inc 功能描述:SBC Gen2 with CAN High Speed and LIN Interface
MCZ33903BD3EK 功能描述:CAN 接口集成电路 Canvas 32 DL (3.3V) RoHS:否 制造商:Texas Instruments 类型:Transceivers 工作电源电压:5 V 电源电流: 工作温度范围:- 40 C to + 85 C 封装 / 箱体:SOIC-8 封装:Tube
MCZ33903BD3EKR2 功能描述:CAN 接口集成电路 Canvas 32 DL (3.3V) RoHS:否 制造商:Texas Instruments 类型:Transceivers 工作电源电压:5 V 电源电流: 工作温度范围:- 40 C to + 85 C 封装 / 箱体:SOIC-8 封装:Tube
MCZ33903BD3R2 制造商:FREESCALE 制造商全称:Freescale Semiconductor, Inc 功能描述:SBC Gen2 with CAN High Speed and LIN Interface