DATA SHEET
PM7367 FREEDM-32P32
ISSUE 2
PMC-1991499
FRAME ENGINE AND DATA LINK MANAGER
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMER’S INTERNAL USE
241
OFDET:
The overflow detect bit (OFDET) indicates the status of the PMON Receive
FIFO Overflow Count register. OFDET is set high when overflow events have
occurred during the latest PMON accumulation interval. OFDET is set low if
no overflow events are detected.
UFDET:
The underflow detect bit (UFDET) indicates the status of the PMON Transmit
FIFO Underflow Count register. UFDET is set high when underflow events
have occurred during the latest PMON accumulation interval. UFDET is set
low if no underflow events are detected.
C1DET:
The configurable event #1 detect bit (C1DET) indicates the status of the
PMON Configurable Count #1 register. C1DET is set high when selected
events have occurred during the latest PMON accumulation interval. C1DET
is set low if no selected events are detected.
C2DET:
The configurable event #2 detect bit (C2DET) indicates the status of the
PMON Configurable Count #2 register. C2DET is set high when selected
events have occurred during the latest PMON accumulation interval. C2DET
is set low if no selected events are detected.