参数资料
型号: TSS463-AA
英文描述: TSS463-AA [Updated 3/03. 60 Pages]
中文描述: TSS463 -机管局[更新3月3日。 60页]
文件页数: 18/52页
文件大小: 268K
代理商: TSS463-AA
TSS461C
18
Rev. D (22 Feb 01)
Status bits give permanent information on the diagnosis performed, whatever the programmed operating mode. This
is encoded over three bits: Sa, Sb and Sc.
Sa and Sb bits indicate the four possible states of the VAN bus
Table 1. Status bits: Sa & Sb
Sa
Sb
Communication
Mode
nominal
0
0
Fault
no fault on VAN bus
Status
differential communication on DATA and DATA
Mode
degraded on DATA
0
1
Fault
fault on DATA
Status
communication on DATA
Mode
degraded on DATA
1
0
Fault
fault on DATA
Status
communication on DATA
Mode
major error
1
1
Fault
fault on DATA and DATA
Status
no communication on DATA and DATA (attempt to communicate alternatively on
DATA then DATA every SDC period)
Sc bit sets to 1 as soon as one of the three inputs (RXD2, RXD1, RXD0) differs from the others in the input
comparison analysis performs by the diagnosis system, S2 is set.
The only ways to reset this status bit are through the RI signal or a general reset.
8.2. Internal Operations
8.2.1. Digital Filtering
If several spurious pulses occur during one bit, the diagnosis for defective conductor may be corrupted. To avoid such
errors, digital filters are implemented.
Filtering operation is based on sampling of the comparator output signals. A transition is taken into account only if
it is observed over five samples (1/16
th
of timeslot).
8.2.2. Transition Analyses
These analyses are continuously done on the effective edges on comparators after digital filtering.
Asynchronous diagnosis
The asynchronous diagnosis is done by comparing the number of edges on DATA and DATA.
If four edges are detected on one input and no edges on the other during the same peiod, the second input is
considered faulty and the diagnosis mode will change to one of the degraded modes.
Synchronous diagnosis
The synchronous diagnosis counts the number of edges on the data input connected to the reception logic during
one SDC period.
If there are less than four edges during one SDC period, the diagnosis mode will change to the major error mode.
相关PDF资料
PDF描述
TSS463D Industrial Control IC
TSS463R Industrial Control IC
TSS461E VAN Data Link Controller
TSS461E-TDRA-9 VAN Data Link Controller
TSS461E-TERA-9 VAN Data Link Controller
相关代理商/技术参数
参数描述
TSS463-AA_04 制造商:ATMEL 制造商全称:ATMEL Corporation 功能描述:VAN Data Link Controller with Serial Interface
TSS463-AAR 制造商:ATMEL 制造商全称:ATMEL Corporation 功能描述:VAN Data Link Controller with Serial Interface
TSS463A-TERZ 功能描述:网络控制器与处理器 IC ASICS RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray