参数资料
型号: XC09-009WNC
厂商: Digi International/Maxstream
文件页数: 14/36页
文件大小: 826K
描述: MOD RF 900MHZ 9600BPS W/WIRE ANT
标准包装: 1
系列: 9XCite OEM 模块
频率: 900MHz
数据传输率 - 最大: 9.6kbps
调制或协议: FHSS,FSK
功率 - 输出: 6dBm
灵敏度: -108dBm
电源电压: 2.85 V ~ 5.5 V
电流 - 接收: 45mA
电流 - 传输: 55mA
数据接口: PCB,通孔
天线连接器: 板载,导线天线
工作温度: 0°C ~ 70°C
封装/外壳: 模块
9XCite"燨EM燫F燤odule?燩roduct燤anual爒2.1燵2007.01.04]
2007燤axStream,營nc.
牋牋?4
2.2.5. Command Mode
AT Command Mode provides access to AT-Settable parameters. These parameters extend flexibil-
ity in configuring modems to fit specific design criteria such as networking modems. Not all of the
parameters in the XCite Module can be adjusted using AT Commands.
AT Command Mode
To Enter AT Command Mode:
Default AT Command Mode Sequence (for transition to Command Mode):
" No characters sent for one second [refer to the BT (Guard Time Before) Command]
" Input three plus characters (+++) within one second
[refer to the CC (Command Sequence Character) Command.]
" No characters sent for one second [refer to the AT (Guard Time After) Command.]
All of the parameter values in the sequence can be modified to reflect user preferences.
To Send AT Commands:
Figure?08.燬yntax爁or爏ending燗T燙ommands?/DIV>
To read a parameter value stored in the module register, leave the parameter field blank.
The preceding example would change the modules Destination Address to "0x1F". To store the
new value to non-volatile (long term) memory, the Write (ATWR) command must subsequently be
sent before powering off the module.
System Response. When a command is sent to the module, the module will parse and execute 
the command. Upon successful execution of a command, the module returns an OK message. If
execution of a command results in an error, the module returns an ERROR message.
To Exit AT Command Mode:
For an example of programming the RF module using AT Commands and descriptions of each config-
urable parameter, refer to the "RF Module Configuration" chapter.
1.   Send the 3-character command sequence "+++" and observe guard times before and after
the command characters. [refer to Default AT Command Mode Sequence below.] The Ter-
minal tab (or other serial communications software) of the X-CTU Software can be used to
enter the sequence.
[OR]
2.   Assert (low) the CONFIG
 pin and turn the power going to the RF modem off and back on. To
achieve this result, simultaneously press the Reset and Config switches [Figure 1-02];
release the Reset Switch; then after 1 second, release the Config Switch. The RF Modem
then enters AT Command Mode at the modem's default baud rate
Send AT commands and parameters using the syntax shown below.
1.   If no valid AT Commands are received within the time specified by CT (Command Mode
Timeout) Command, the module automatically returns to Idle Mode.
  [OR]
2.   Send ATCN (Exit Command Mode) Command.
相关PDF资料
PDF描述
FAR-F5KY-740M00-B4UR-Z FILTER SAW 740MHZ LTE XVII SMD
IF-14-30 XFRMR 115/230V 15V 940MA PCB
IF-14-24 XFRMR 115/230V 12V 1.2A 14VA PCB
RF100PC6 RF ENGINE F-ANT MAX RANGE
IF-14-230 XFRMR 115/230V 115V 120MA PCB
相关代理商/技术参数
参数描述
XC09-009WNI 功能描述:射频模块 9XCite 4mW transcei re antenna 9600 bps RoHS:否 制造商:Linx Technologies 产品:Transceiver Modules 频带:902 MHz to 928 MHz 输出功率:- 15.5 dBm to + 12.5 dBm 接口类型:UART 工作电源电压:- 0.3 VDC to + 5.5 VDC 传输供电电流:38.1 mA 接收供电电流:22.7 mA 天线连接器类型:U.FL 最大工作温度:+ 85 C 尺寸:1.15 mm x 0.63 mm x 0.131 mm
XC0900A-03P 制造商:ANAREN 制造商全称:Anaren Microwave 功能描述:Hybrid Coupler 3 dB, 90∑
XC0900A-03S 功能描述:信号调节 811-1000MHz IL:.12dB VSWR:1.12 -55 to 95C RoHS:否 制造商:EPCOS 产品:Duplexers 频率:782 MHz, 751 MHz 频率范围: 电压额定值: 带宽: 阻抗:50 Ohms 端接类型:SMD/SMT 封装 / 箱体:2.5 mm x 2 mm 工作温度范围:- 30 C to + 85 C 封装:Reel
XC0900A-03S-CT 制造商:Anaren Microwave 功能描述:RF HYBRID COUPLER
XC0900A-03SR 制造商:Anaren Microwave 功能描述:HYBRID COUPLERS