参数资料
型号: XR16C850CJ-F
厂商: Exar Corporation
文件页数: 13/56页
文件大小: 0K
描述: IC UART FIFO 128B 44PLCC
标准包装: 27
特点: *
通道数: 1,UART
FIFO's: 128 字节
规程: RS485
电源电压: 2.97 V ~ 5.5 V
带自动流量控制功能:
带IrDA 编码器/解码器:
带故障启动位检测功能:
带调制解调器控制功能:
带CMOS:
安装类型: 表面贴装
封装/外壳: 44-LCC(J 形引线)
供应商设备封装: 44-PLCC(16.59x16.59)
包装: 管件
XR16C850
xr
2.97V TO 5.5V UART WITH 128-BYTE FIFO
REV. 2.3.1
20
2.17
Auto Xon/Xoff (Software) Flow Control
When software flow control is enabled (See Table 14), the 850 compares one or two sequential receive data
characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the
programmed values, the 850 will halt transmission (TX) as soon as the current character has completed
transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output
pin will be activated. Following a suspension due to a match of the Xoff character, the 850 will monitor the
receive data stream for a match to the Xon-1,2 character. If a match is found, the 850 will resume operation
and clear the flags (ISR bit-4).
Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0. Following reset the user
can write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/
Xoff characters (See Table 14) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are
selected, the 850 compares two consecutive receive characters with two software flow control 8-bit values
(Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control
mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO.
In the event that the receive buffer is overfilling and flow control needs to be executed, the 850 automatically
sends an Xoff message (when enabled) via the serial TX output to the remote modem. The 850 sends the Xoff-
1,2 characters two-character-times (= time taken to send two characters at the programmed baud rate) after
the receive FIFO crosses the programmed trigger level (for all trigger tables A-D). To clear this condition, the
850 will transmit the programmed Xon-1,2 characters as soon as receive FIFO is less than one trigger level
below the programmed trigger level (for Trigger Tables A, B, and C) or when receive FIFO is less than the
trigger level minus the hysteresis value (for Trigger Table D). This hysteresis value is the same as the Auto
RTS Hysteresis value in Table 5. Table 6 below explains this when Trigger Table-B (See Table 10) is
selected.
* After the trigger level is reached, an xoff character is sent after a short span of time (= time required to send 2
characters); for example, after 2.083ms has elapsed for 9600 baud and 10-bit word length setting.
2.18
Special Character Detect
A special character detect feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced
Feature Register (EFR). When this character (Xoff2) is detected, it will be placed in the FIFO along with normal
incoming RX data.
The 850 compares each incoming receive character with Xoff-2 data. If a match exists, the received data will
be transferred to FIFO and ISR bit-4 will be set to indicate detection of special character. Although the Internal
Register Table shows Xon, Xoff Registers with eight bits of character information, the actual number of bits is
dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of
character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also
determines the number of bits that will be used for the special character comparison. Bit-0 in the Xon, Xoff
Registers corresponds with the LSB bit for the receive character.
2.19
Auto RS485 Half-duplex Control
The auto RS485 half-duplex direction control changes the behavior of the transmitter when enabled by MCR
bit-2. It de-asserts OP1#/RS485 output following the last stop bit of the last character that has been
transmitted. This helps in turning around the transceiver to receive the remote station’s response. When the
host is ready to transmit next polling data packet again, it only has to load data bytes to the transmit FIFO. The
transmitter automatically re-asserts OP1# output prior to sending the data. See Figure 14.
TABLE 6: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL
RX TRIGGER LEVEL
INT PIN ACTIVATION
XOFF CHARACTER(S) SENT
(CHARACTERS IN RX FIFO)
XON CHARACTER(S) SENT
(CHARACTERS IN RX FIFO)
8
8*
0
16
16*
8
24
24*
16
28
28*
24
相关PDF资料
PDF描述
MS3116F16-23P CONN PLUG 23POS STRAIGHT W/PINS
XR16C2852CJTR-F IC UART FIFO 128B 44PLCC
D38999/20FB5SA CONN RCPT 5POS WALL MNT W/SCKT
XR16C2850CJTR-F IC UART FIFO 128B 44PLCC
XR68C192IJ-F IC UART FIFI DUAL 44PLCC
相关代理商/技术参数
参数描述
XR16C850CJTR-F 制造商:Exar Corporation 功能描述:UART 1-CH 128Byte FIFO 3.3V/5V 44-Pin PLCC T/R 制造商:Exar Corporation 功能描述:XR16C850CJTR-F
XR16C850CM 制造商:Rochester Electronics LLC 功能描述: 制造商:Exar Corporation 功能描述:
XR16C850CM-0A-EVB 功能描述:UART 接口集成电路 Supports C850 48 ld TQFP, ISA Interface RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel
XR16C850CM-F 功能描述:UART 接口集成电路 UARTW/128BYTE FIFO RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel
XR16C850CMTR-F 功能描述:UART 接口集成电路 UART w/128 Bytes FIFO & IrDA RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel