参数资料
型号: XRT83SL314IB-L
厂商: Exar Corporation
文件页数: 31/83页
文件大小: 0K
描述: IC LIU SH T1/E1/J1 14CH 304TBGA
标准包装: 27
类型: 线路接口装置(LIU)
驱动器/接收器数: 14/14
规程: T1,E1,J1
电源电压: 3.135 V ~ 3.465 V
安装类型: 表面贴装
封装/外壳: 304-LBGA
供应商设备封装: 304-TBGA(31x31)
包装: 托盘
xr
XRT83SL314
14-CHANNEL T1/E1/J1 SHORT-HAUL LINE INTERFACE UNIT
REV. 1.0.1
34
3.4
Power Failure Protection
For 1:1 or 1+1 line card redundancy in T1/E1 applications, power failure could cause a line card to change the
characteristics of the line impedance, causing a degradation in system performance. The XRT83SL314 was
designed to ensure reliability during power failures. The LIU has patented high impedance circuits that allow
the receiver inputs and the transmitter outputs to be in "High" impedance when the LIU experiences a power
failure or when the LIU is powered off.
NOTE: For power failure protection, a transformer must be used to couple to the line interface. See the TAN-56 application
note for more details.
3.5
Overvoltage and Overcurrent Protection
Physical layer devices such as LIUs that interface to telecommunications lines are exposed to overvoltage
transients posed by environmental threats. An Overvoltage transient is a pulse of energy concentrated over a
small period of time, usually under a few milliseconds. These pulses are random and exceed the operating
conditions of CMOS transceiver ICs. Electronic equipment connecting to data lines are susceptible to many
forms of overvoltage transients such as lightning, AC power faults and electrostatic discharge (ESD). There
are three important standards when designing a telecommunications system to withstand overvoltage
transients.
UL1950 and FCC Part 68
Telcordia (Bellcore) GR-1089
ITU-T K.20, K.21 and K.41
NOTE:
For a reference design and performance, see the TAN-54 application note for more details.
3.6
Non-Intrusive Monitoring
In non-intrusive monitoring applications, the transmitters are shut off by setting TxON "Low". The receivers
must be actively receiving data without interfering with the line impedance.
The XRT83SL314’s internal
termination ensures that the line termination meets T1/E1 specifications for 75
, 100 or 120 while
monitoring the data stream. System integrity is maintained by placing the non-intrusive receiver in "High"
impedance, equivalent to that of a 1+1 redundancy application. A simplified block diagram of non-intrusive
monitoring is shown in Figure 28.
FIGURE 28. SIMPLIFIED BLOCK DIAGRAM OF A NON-INTRUSIVE MONITORING APPLICATION
Line Card Transceiver
Non-Intrusive Receiver
Node
XRT83SL314
Data Traffic
相关PDF资料
PDF描述
XRT83SL34IV-F IC LIU T1/E1/J1 QUAD 128TQFP
XRT83SL38IB-F IC LIU SH T1/E1/J1 OCTAL 225BGA
XRT83VL38IB-F IC LIU SH T1/E1/J1 OCTAL 225BGA
XRT83VSH28IB IC LIU SH E1 OCTAL 225BGA
XRT83VSH314IB-F IC LIU SH T1/E1/J1 14CH 304TBGA
相关代理商/技术参数
参数描述
XRT83SL34 制造商:EXAR 制造商全称:EXAR 功能描述:QUAD T1/E1/J1 SH TRANSCEIVER WITH CLOCK RECOVERY AND JITTER ATTENUATOR
XRT83SL34ES 功能描述:外围驱动器与原件 - PCI 4 CHT1/E1 LIUSH RoHS:否 制造商:PLX Technology 工作电源电压: 最大工作温度: 安装风格:SMD/SMT 封装 / 箱体:FCBGA-1156 封装:Tray
XRT83SL34IV 功能描述:时钟合成器/抖动清除器 RoHS:否 制造商:Skyworks Solutions, Inc. 输出端数量: 输出电平: 最大输出频率: 输入电平: 最大输入频率:6.1 GHz 电源电压-最大:3.3 V 电源电压-最小:2.7 V 封装 / 箱体:TSSOP-28 封装:Reel
XRT83SL34IV-F 功能描述:时钟合成器/抖动清除器 RoHS:否 制造商:Skyworks Solutions, Inc. 输出端数量: 输出电平: 最大输出频率: 输入电平: 最大输入频率:6.1 GHz 电源电压-最大:3.3 V 电源电压-最小:2.7 V 封装 / 箱体:TSSOP-28 封装:Reel
XRT83SL38 制造商:EXAR 制造商全称:EXAR 功能描述:OCTAL T1/E1/J1 SH TRANSCEIVER WITH CLOCK RECOVERY AND JITTER ATTENUATOR