参数资料
型号: 37C669
厂商: SMSC Corporation
英文描述: DIODE SCHOTTKY SINGLE 25V 200mW 0.5V-vf 200mA-IFM 30mA-IF 2uA-IR SOD-323 3K/REEL
中文描述: 电脑98/99顺从超级I / O软盘控制器与红外线支持
文件页数: 120/164页
文件大小: 621K
代理商: 37C669
59
Read Deleted Data
This command is the same as the Read Data
command, only it operates on sectors that
contain a Deleted Data Address Mark at the
beginning of a Data Field.
Table 25 describes the effect of the SK bit on
the Read Deleted Data command execution and
results.
Except where noted in Table 25, the C or R
value of the sector address is automatically
incremented (see Table 26).
Table 23 - Skip Bit vs. Read Deleted Data Command
RESULTS
SK BIT
VALUE
DATA ADDRESS
MARK TYPE
ENCOUNTERED
SECTOR
READ?
CM BIT OF
ST2 SET?
DESCRIPTION
OF RESULTS
0
1
Normal Data
Deleted Data
Normal Data
Deleted Data
Yes
No
Yes
No
Yes
No
Address not
incremented.
Next sector not
searched for.
Normal
termination.
Normal
termination.
Sector not read
("skipped").
Normal
termination.
Read A Track
This command is similar to the Read Data
command except that the entire data field is
read continuously from each of the sectors of a
track.
Immediately after encountering a pulse
on the nINDEX pin, the FDC starts to read
all data fields on the track as continuous blocks
of data without regard to logical sector numbers.
If the FDC finds an error in the ID or DATA CRC
check bytes, it continues to read data from the
track and sets the appropriate error bits at the
end of the command. The FDC compares the
ID information read from each sector with the
specified
value
in
the
command
and
sets the
ND flag of Status Register 1
to a "1" if there is no comparison. Multi-track or
skip operations are not allowed with this
command. The MT and SK bits (bits D7 and D5
of the first command byte respectively) should
always be set to "0".
This
command
terminates
when
the
EOT
specified number of sectors has not been read.
If the FDC does not find an ID Address Mark on
the diskette after the second occurrence of a
pulse on the IDX pin, then it sets the IC code in
Status
Register
0
to
"01"
(abnormal
termination), sets the MA bit in Status Register
1 to "1", and terminates the command.
相关PDF资料
PDF描述
37C672 ENHANCED SUPER I/O CONTROLLER WITH FAST IR
37C67X ENHANCED SUPER I/O CONTROLLER WITH FAST IR
37C957FR ULTRA I/O CONTROLLER FOR PORTABLE APPLICATIONS
37FMA1-ABW31N SPECIAL SWITCH-PIEZO SWITCH, SPST, MOMENTARY, 0.2A, 24VDC, PANEL MOUNT-THREADED
37FML1-BEW31N SPECIAL SWITCH-PIEZO SWITCH, SPST, MOMENTARY, 0.2A, 24VDC, PANEL MOUNT-THREADED
相关代理商/技术参数
参数描述
37C672 制造商:SMSC 制造商全称:SMSC 功能描述:ENHANCED SUPER I/O CONTROLLER WITH FAST IR
37C67X 制造商:SMSC 制造商全称:SMSC 功能描述:ENHANCED SUPER I/O CONTROLLER WITH FAST IR
37C-6BH-5-5 制造商:Birtcher Products 功能描述:
37C72U-185 制造商:White-Rodgers 功能描述:
37C73U-170 制造商:White-Rodgers 功能描述: