参数资料
型号: 71M6511-DB
厂商: Maxim Integrated Products
文件页数: 31/115页
文件大小: 0K
描述: BOARD DEMO 71M6511 ENERGY METER
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 1
主要目的: 电源管理,电度表/功率表
嵌入式:
已用 IC / 零件: 71M6511
已供物品: 2 个板,线缆,CD,电源
71M6511/71M6511H Demo Board User’s Manual
CE
Constant
CAL_VA
RESERVED
RESERVED
CAL_I0
CAL_I1
RESERVED
PHADJ_0
PHADJ_1 1
RESERVED
TEMP_NOM
Address
(hex)
0x09
0x0B
0x0D
0x08
0x0A
0x0C
0x0E
0x0F
0x10
0x11
Description
Adjusts the gain of the voltage channel. +16384 is the typical value. The
gain is directly proportional to the CAL parameter. Allowed range is 0 to
32767. If the gain is 1% slow, CAL should be increased by 1%.
Adjusts the gain of the current channels. +16384 is the typical value.
The gain is directly proportional to the CAL parameter. Allowed range is
0 to 32767. If the gain is 1% slow, CAL should be increased by 1%.
This constant controls the CT phase compensation. No compensation
occurs when PHADJ=0. As PHADJ is increased, more compensation is
introduced.
Note: PHASDJ_1 1 applies to 3W/1-phase systems.
TEMP_RAWX reading
Table 1-4: CE RAM Locations for Calibration Constants
1.9.2 CALIBRATION MACRO FILE
Once, calibration parameters (calibration constants) have been determined, instead of manually typing them
in using the command line interface, macro files may be used to simplify this procedure.
The macro file in Figure 1-11 contains a sequence of the serial interface commands that implements
changes to the calibration parameters (CE address locations 0x08 to 0x10). It is a simple text file and can be
created with Notepad or an equivalent ASCII editor program.
The file is executed with the following command of the HyperTerminal program:
Transfer->Send Text File .
]8=+16022/
]9=+16381/
]a=+16019/
]e=+115/
]f=+113/
ce1
CAL_IA (gain=CAL_IA/16384)
CAL_VA (gain=CAL_VA/16384)
CAL_IB (gain=CAL_IB/16384)
PHADJ_A (default 0)
PHADJ_B (default 0)
Figure 1-11: Typical Calibration Macro file
It is possible to send the calibration macro file to the 71M6511/71M6511H for “temporary” calibration. This
will temporarily change the CE data values. Upon power up, these values are refreshed back to the default
values stored in flash memory. Thus, until the flash memory is updated, the macro file must be loaded each
time the part is powered up. The macro file is run by first issuing the CE0 command to turn off the compute
engine and then sending the file with the transfer
send text file procedure.
Note: Use the Transfer
Send Text File command!
Revision 5.4
? 2005-2007 TERIDIAN Semiconductor Corporation
Page: 31 of 115
相关PDF资料
PDF描述
71M6513H-DB BOARD DEMO 71M6513H ENERGY METER
71M6515H-DB BOARD DEMO 71M6515H ENERGY METER
71M6521FE-DB BOARD DEMO FOR 71M6521FE
71M6531F-DB BOARD DEMO 71M6531F
71M6533-DB BOARD DEMO 71M6533
相关代理商/技术参数
参数描述
71M6511H 制造商:TERIDIAN 制造商全称:TERIDIAN 功能描述:Single-Phase Energy Meter IC
71M6511H-DB 功能描述:开发板和工具包 - 8051 71M6511H Demo Brd RoHS:否 制造商:Silicon Labs 产品:Development Kits 工具用于评估:C8051F960, Si7005 核心: 接口类型:USB 工作电源电压:
71M6511H-IGT 制造商:TERIDIAN 制造商全称:TERIDIAN 功能描述:Single-Phase Energy Meter IC
71M6511H-IGT/F 功能描述:计量片上系统 - SoC Highly Integrated SoC w/MCU Core RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6511H-IGTR 制造商:Maxim Integrated Products 功能描述:RESID. HI PRECISION METR (1P, .1%) - Tape and Reel