参数资料
型号: 71M6521FE-IGT/F
厂商: MAXIM INTEGRATED PRODUCTS INC
元件分类: 模拟信号调理
英文描述: SPECIALTY ANALOG CIRCUIT, QFP64
封装: LEAD FREE, LQFP-64
文件页数: 57/103页
文件大小: 1691K
代理商: 71M6521FE-IGT/F
71M6521DE/71M6521FE
Energy Meter IC
DATA SHEET
OCTOBER 2010
v1.1
2005-2010 Teridian Semiconductor Corporation
Page: 57 of 103
A Maxim Integrated Products Brand
19-5370; 10/10
time
VBAT
MPU Mode
Battery
Current
MPU Clock
Source
Xtal
PLL_OK
WAKE
Internal
RESETZ
1024 CK32
cycles
BROWNOUT
14.5 CK32
cycles
VBAT_OK
Figure 24: Power-Up Timing with VBAT only
Fault and Reset Behavior
Reset Mode: When the RESET pin is pulled high all digital activity stops. The oscillator and RTC module continue to run.
Additionally, all I/O RAM bits are set to their default states. As long as V1, the input voltage at the power fault block, is greater
than VBIAS, the internal 2.5V regulator will continue to provide power to the digital section.
Once initiated, the reset mode will persist until the reset timer times out, signified by the internal signal WAKE rising. This will
occur in 4100 cycles of the real time clock after RESET goes low, at which time the MPU will begin executing its preboot and
boot sequences from address 00. See the security section for more description of preboot and boot.
If system power is not present, the reset timer duration will be 2 cycles of the crystal clock, at which time the MPU will begin
executing in BROWNOUT mode, starting at address 00.
Power Fault Circuit: The 71M6521DE/FE includes a comparator to monitor system power fault conditions. When the output
of the comparator falls (V1<VBIAS), the I/P RAM bits PLL_OK is zeroed and the part switches to BROWNOUT mode if a
battery is present. Once, system power returns, the MPU remains in reset and does not start Mission Mode until 4100
oscillator clocks later, when PLL_OK rises. If a battery is not present, indicated by BAT_OK=0, WAKE will fall and the part will
enter SLEEP mode.
There are several conditions the part could be in as system power returns. If the part is in BROWNOUT mode, it will auto-
matically switch to mission mode when PLL_OK rises. It will receive an interrupt indicating this. No configuration bits will be
reset or reconfigured during this transition.
If the part is in LCD or SLEEP mode when system power returns, it will also switch to mission mode when PLL_OK rises. In
this case, all configuration bits will be in the reset state due to WAKE having been zero. The RTC clock will not be disturbed,
but the MPU RAM must be re-initialized. The hardware watchdog timer will become active when the part enters MISSION
mode.
相关PDF资料
PDF描述
71M6531D-IMR/F 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, QCC68
71M6532D-IGTR/F 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PQFP100
71M6532F-IGT/F 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PQFP100
71M6531D-IM/F 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, QCC68
71M6531F-IMR/F 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, QCC68
相关代理商/技术参数
参数描述
71M6521FE-IGTR 制造商:Maxim Integrated Products 功能描述:Metering Systems on a Chip - SoC Residential Energy Meter IC
71M6521FE-IGTR/F 功能描述:计量片上系统 - SoC Residential Energy Meter IC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6521FE-IGTR/F1 功能描述:计量片上系统 - SoC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6521FE-IM 制造商:Maxim Integrated Products 功能描述:Metering Systems on a Chip - SoC Residential Energy Meter IC
71M6521FE-IM/F 功能描述:计量片上系统 - SoC Residential Energy Meter IC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel