参数资料
型号: A1361LKTTN-T
元件分类: 磁阻传感器
英文描述: MAGNETIC FIELD SENSOR-HALL EFFECT, 4.65-4.80V, RECTANGULAR, THROUGH HOLE MOUNT
封装: LEAD FREE, PLASTIC, SIP-4
文件页数: 8/25页
文件大小: 615K
代理商: A1361LKTTN-T
A1360, A1361,
and A1362
Parameter Selection
Each of the four programmable parameters can be accessed
through its corresponding parameter register. These registers are
located in two distinct zones in the A136x devices:
Zone 1, Register 1:
Fine sensitivity, Sens
Zone 2, Register 1:
Fine quiescent voltage output, VOUT(Q)
Zone 2, Register 2:
Coarse quiescent voltage output, VOUT(Q)
Overall device locking, LOCK
To select the register in the first zone, a sequence of one VPH
pulse, the key for the register, and a second VPH pulse (with no
VCC supply interruptions) must be applied serially to the VOUT
pin. The pulse train used for selection of the first register, key 1,
is shown in figure 1.
V+
0
tLOW
tACTIVE
VP(HIGH)
VP(MID)
VP(LOW)
Figure 1. Voltage pulse sequence required to select the first
programmable register in the first zone.
After the falling edge of the second VPH pulse, the bit field of the
selected register may be addressed with the appropriate code (see
Bit Field Addressing section, below).
The first zone must be traversed before the second zone can be
accessed. After completing any bit field addressing in the first
zone, to enter the second zone, apply a third VPH pulse. As in
the first zone, this must be followed by the key for the parameter
register, then a VPH pulse and the bit field code (with no VCC
supply interruptions).
Bit Field Addressing
After the register of a programmable parameter has been selected
as described above, the code pulses must be applied serially to
the VOUT pin with no VCC supply interruptions. As each addi-
tional pulse in the code is transmitted, the overall setting of the
bit field increments by 1, up to the maximum possible code for
that register (see the Programming Logic table). The A136x logic
interprets the overall setting (the binary sum of all of the acti-
vated or blown fuses) and applies it to the value of the parameter,
according to the step size for the parameter (shown in the Electri-
cal Characteristics table).
Addressing activates the corresponding fuse locations in the
given bit field by incrementing the binary value of an internal
DAC. Measurements can be taken after each pulse to determine
if the desired result for the programmable parameter has been
reached. Cycling the supply voltage resets all the locations in the
bit field that have unblown fuses to their initial states.
tLOW
tACTIVE
VP(MID)
VP(LOW)
V+
0
Code
1
Code
2
Code
3
Code
2
n
Code
2
n
–1
Code
2
n
–2
Figure 2. Bit eld addressing pulse train. Addressing the bit eld by incre-
menting the code causes the programmable parameter value to change.
The number of bits available for a given programming code, n, varies
among parameters; for example, the bit eld for Sensitivity has 8 bits avail-
able, which allows 255 separate codes to be used.
Fuse Blowing
After the required code is found for a given parameter, its value
can be set permanently by blowing individual fuses in the appro-
priate register bit field. Blowing is accomplished by applying a
high voltage pulse, called a blow pulse, of sufficient duration to
permanently set an addressed bit by blowing a fuse internal to the
device. Due to power requirements, the fuse for each bit in the
bit field must be blown individually. To accomplish this, the code
representing the desired parameter value must be translated to a
binary number. For example, as shown in figure 3, decimal code
5 is equivalent to the binary number 101. Therefore bit 2 (code
4) must be addressed and blown, the device power supply cycled,
and then bit 0 (code 1) addressed and blown. The order of blow-
ing bits, however, is not important. Blowing bit 0 first, and then
bit 2, is acceptable.
Programming Procedures
Low-Noise Programmable Linear Hall Effect Sensor ICs with
Adjustable Bandwidth (50 kHz Maximum) and Analog Output
16
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
相关PDF资料
PDF描述
A150N50X4A 0 MHz - 2700 MHz 50 ohm RF/MICROWAVE TERMINATION
A15QS1-2 FAST BLOW ELECTRIC FUSE, 1A, 150VAC, 150VDC, 100000A (IR), INLINE/HOLDER
A15QS10-2 FAST BLOW ELECTRIC FUSE, 10A, 150VAC, 150VDC, 100000A (IR), INLINE/HOLDER
A15QS100-4TI FAST BLOW ELECTRIC FUSE, 100A, 150VAC, 150VDC, 100000A (IR), INLINE/HOLDER
A15QS100-4 FAST BLOW ELECTRIC FUSE, 100A, 150VAC, 150VDC, 100000A (IR), INLINE/HOLDER
相关代理商/技术参数
参数描述
A1362LKTTN-T 功能描述:IC HALL EFFECT SENSOR LN 4-SIP RoHS:是 类别:传感器,转换器 >> 磁性 - 霍尔效应,数字式开关,线性,罗盘 (IC) 系列:- 标准包装:1 系列:- 传感范围:20mT ~ 80mT 类型:旋转 电源电压:4.5 V ~ 5.5 V 电流 - 电源:15mA 电流 - 输出(最大):- 输出类型:数字式,PWM,8.5 位串行 特点:可编程 工作温度:-40°C ~ 150°C 封装/外壳:20-SSOP(0.209",5.30mm 宽) 供应商设备封装:20-SSOP 包装:Digi-Reel® 其它名称:AS5132-HSST-500DKR
A1363LKTTN-10-T 功能描述:IC HALL SENSOR 6.4-14MV/G 4SIP 制造商:allegro microsystems, llc 系列:- 包装:剪切带(CT) 零件状态:有效 类型:线性 技术:霍尔效应 轴:单路 感应范围:- 电压 - 电源:4.5 V ~ 5.5 V 电流 - 电源(最大值):15mA 电流 - 输出(最大值):10mA 输出类型:模拟电压 分辨率:- 带宽:120kHz 工作温度:-40°C ~ 150°C(TA) 特性:可编程,温度补偿 封装/外壳:4-SIP 模块 供应商器件封装:4-SIP 标准包装:1
A1363LKTTN-1-T 功能描述:IC HALL SENSOR 0.6-1.3MV/G 4SIP 制造商:allegro microsystems, llc 系列:- 包装:剪切带(CT) 零件状态:有效 类型:线性 技术:霍尔效应 轴:单路 感应范围:- 电压 - 电源:4.5 V ~ 5.5 V 电流 - 电源(最大值):15mA 电流 - 输出(最大值):10mA 输出类型:模拟电压 分辨率:- 带宽:120kHz 工作温度:-40°C ~ 150°C(TA) 特性:可编程,温度补偿 封装/外壳:4-SIP 模块 供应商器件封装:模块 标准包装:1
A1363LKTTN-2-T 功能描述:IC HALL SENSOR 1.3-2.9MV/G 4SIP 制造商:allegro microsystems, llc 系列:- 包装:剪切带(CT) 零件状态:有效 类型:线性 技术:霍尔效应 轴:单路 感应范围:- 电压 - 电源:4.5 V ~ 5.5 V 电流 - 电源(最大值):15mA 电流 - 输出(最大值):10mA 输出类型:模拟电压 分辨率:- 带宽:120kHz 工作温度:-40°C ~ 150°C(TA) 特性:可编程,温度补偿 封装/外壳:4-SIP 模块 供应商器件封装:4-SIP 标准包装:1
A1363LKTTN-5-T 功能描述:IC HALL SENSOR 2.9-6.4MV/G 4SIP 制造商:allegro microsystems, llc 系列:- 包装:剪切带(CT) 零件状态:有效 类型:线性 技术:霍尔效应 轴:单路 感应范围:- 电压 - 电源:4.5 V ~ 5.5 V 电流 - 电源(最大值):15mA 电流 - 输出(最大值):10mA 输出类型:模拟电压 分辨率:- 带宽:120kHz 工作温度:-40°C ~ 150°C(TA) 特性:可编程,温度补偿 封装/外壳:4-SIP 模块 供应商器件封装:4-SIP 标准包装:1