参数资料
型号: ADE7166ASTZF16
厂商: Analog Devices Inc
文件页数: 55/152页
文件大小: 0K
描述: IC ENERGY METER 1PHASE 64LQFP
标准包装: 1
输入阻抗: *
测量误差: *
电压 - 高输入/输出: *
电压 - 低输入/输出: *
电流 - 电源: *
电源电压: *
测量仪表类型: *
工作温度: *
安装类型: 表面贴装
封装/外壳: 64-LQFP
供应商设备封装: 64-LQFP(10x10)
包装: 托盘
ADE7116/ADE7156/ADE7166/ADE7169/ADE7566/ADE7569
Fault with Inactive Input Greater Than Active Input
If the difference between I PB , the inactive input, and I PA , the
active input (that is, being used for billing), becomes greater
I PB
0
CT
R B
R F
V A
C F
I PA
than 6.25% of I PB , and the FAULTSIGN bit (Bit 6) of the
ACCMODE register (Address 0x0F) is cleared, the FAULTSIGN
AGND
I N
flag (Bit 5) in the Interrupt Status 1 SFR (MIRQSTL, Address
0xDC) is set. The I PB analog input becomes the active input.
Again, a time constant of about 3 seconds is associated with this
swap. I PA does not become the active channel again until I PA is
greater than I PB and the difference between I PA and I PB —in this
order—becomes greater than 6.25% of I PB . However, if the
TEST
CURRENT
R A
R F
CT
R B
C F
0V
R F
R F
C T
V P
V N
C F
I PB
FAULTSIGN bit (Bit 6) of the ACCMODE register (Address 0x0F)
is set, the FAULTSIGN flag (Bit 5) in the Interrupt Status 1 SFR
(MIRQSTL, Address 0xDC) is set as soon as I PA is within 6.25%
of I PB . This threshold eliminates potential chatter between I PA
and I PB .
Calibration Concerns
Typically, when a meter is calibrated, the voltage and current
circuits are separated, as shown in Figure 49. Current passes
through only the phase circuit or the neutral circuit. Figure 49
shows current being passed through the phase circuit. This is
the preferred option because the ADE7116/ADE7156/
ADE7166/ADE7169 start billing on the I PA input on power-up.
The phase circuit CT is connected to I PA in the diagram.
Because the current sensors are not perfectly matched, it is
important to match current inputs. The ADE7116/
ADE7156/ADE7166/ADE7169 provide a gain calibration
register for I PB , IBGAIN (Address 0x1C). IBGAIN is a 12-bit,
signed, twos complement register that provides a gain
resolution of 0.0244%/LSB.
For calibration, a first measurement should be done on I PA by
setting the SEL_I_CH bits to 0b01 in the CALMODE register
(Address 0x3D). This measurement should be compared to the
measurement on I PB . Measuring I PB can be forced by setting the
SEL_I_CH bits to 0b10 in the CALMODE register (Address 0x3D).
The gain error between these two measurements can be evaluated
using the following equation:
V
240V rms
Figure 49. Fault Conditions for Inactive Input Greater Than Active Input
di/dt CURRENT SENSOR AND DIGITAL
INTEGRATOR FOR THE ADE7169/ADE7569
A di/dt sensor, a feature available for the AD7169/ADE7569 but
not for the ADE7116/ADE7156/ADE7166/ADE7169, detects
changes in the magnetic field caused by ac currents. Figure 50
shows the principle of a di/dt current sensor.
MAGNETIC FIELD CREATED BY CURRENT
(DIRECTLY PROPORTIONAL TO CURRENT)
+ EMF (ELECTROMOTIVE FORCE)
– INDUCED BY CHANGES IN
MAGNETIC FLUX DENSITY (di/dt)
Figure 50. Principle of a di/dt Current Sensor
The flux density of a magnetic field induced by a current is
directly proportional to the magnitude of the current. The
changes in the magnetic flux density passing through a conductor
loop generate an electromotive force (EMF) between the two
ends of the loop. The EMF is a voltage signal that is proportional
to the di/dt of the current. The voltage output from the di/dt
current sensor is determined by the mutual inductance between
Error ( % ) =
Measuremen t ( I B ) ? Measuremen t ( I A )
Measuremen t ( I A )
(2)
the current-carrying conductor and the di/dt sensor. The current
signal needs to be recovered from the di/dt signal before it can
be used. An integrator is, therefore, necessary to restore the
The two channels, I PA and I PB , can then be matched by writing
signal to its original form.
?Error(%)/(1 + Error (%)) × 2 12 to the IBGAIN register
(Address 0x1C). This matching adjustment is valid for all
energy measurements made by the ADE7116/ADE7156/
ADE7166/ADE7169, including active power, reactive power
(ADE7169 only), apparent power, and I rms .
Rev. B | Page 55 of 1 5 2
相关PDF资料
PDF描述
GMM06DTMI CONN EDGECARD 12POS R/A .156 SLD
ISL2101AAR3Z-T IC DVR HALF-BRDG HF 100V 2A 9DFN
GSM06DTMI CONN EDGECARD 12POS R/A .156 SLD
LQW18AN15NJ00D INDUCTOR 15NH 600MA 0603
ADE7752AARZ-RL IC ENERGY METERING 3PHASE 24SOIC
相关代理商/技术参数
参数描述
ADE7166ASTZF16-RL 功能描述:IC ENERGY METER 1PHASE 64LQFP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7166ASTZF8 功能描述:IC ENERGY METER 1PHASE 64LQFP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7166ASTZF8-RL 功能描述:IC ENERGY METER 1PHASE 64LQFP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7169 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC and LCD driver
ADE7169ACPF16 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC and LCD driver