参数资料
型号: ADT7467BBZEVB
厂商: ON Semiconductor
文件页数: 56/72页
文件大小: 0K
描述: BOARD EVALUATION FOR ADT7467
产品变化通告: MFG CHG Notification ADI to ON Semi
标准包装: 1
系列: dBCool®
传感器类型: 温度
传感范围: -40°C ~ 120°C
接口: SMBus(2 线/I²C)
灵敏度: ±1.5°C
电源电压: 3 V ~ 5.5 V
嵌入式:
已供物品: 板,缆线,CD
已用 IC / 零件: ADT7467
其它名称: EVAL-ADT7467EBZ
EVAL-ADT7467EBZ-ND
ADT7467
Table 47. OPERATING POINT REGISTERS (POWER-ON DEFAULT = 0XA4) (Notes 1, 2, 3)
Register Address
0x33
0x34
0x35
R/W
Read/Write
Read/Write
Read/Write
Description
Remote 1 Operating Point Register (Default = 100 ? C)
Local Temperature Operating Point Register (Default = 100 ? C)
Remote 2 Operating Point Register (Default = 100 ? C)
1. These registers set the target operating point for each temperature channel when the dynamic T MIN control feature is enabled.
2. The fans being controlled are adjusted to maintain temperature about an operating point.
3. These registers become read-only registers when the Configuration Register 1 LOCK bit is set to 1. Any subsequent attempts to write to
these registers fail.
Table 48. REGISTER 0X36 ? DYNAMIC T MIN CONTROL REGISTER 1 (POWER-ON DEFAULT = 0X00) (Note 1)
Bit
<0>
<1>
<2>
Name
CYR2
V CCP LO
PHTR1
R/W
Read/Write
Read/Write
Read/Write
Description
MSB of 3-bit Remote 2 cycle value. The other two bits of the code reside in Dynamic T MIN Control
Register 2 (0x37). These three bits define the delay time, in terms of the number of monitoring
cycles, for making subsequent T MIN adjustments in the control loop. The system is associated with
thermal time constants that must be found to optimize the response of the fans and the control
loop.
V CCP LO = 1. When the power is supplied from 3.3 V STANDBY and the core voltage (V CCP ) drops
below its V CCP low limit value (Register 0x46), the following occurs:
Status Bit 1 in Interrupt Status Register 1 is set.
SMBALER T is generated if enabled.
PROCHOT monitoring is disabled.
Dynamic T MIN control is disabled.
The device is prevented from entering shutdown.
Everything is re-enabled once V CCP increases above the VCCPLO limit.
PHTR1 = 1 copies the Remote 1 current temperature to the Remote 1 operating point register if
THERM is asserted. The operating point contains the temperature at which THERM is asserted,
allowing the system to run as quietly as possible without affecting system performance.
PHTR1 = 0 ignores THERM assertions on the THERM pin. The Remote 1 operating point register
reflects its programmed value.
<3>
PHTL
Read/Write
PHTL = 1 copies the local channel’s current temperature to the local operating point register if
THERM is asserted. The operating point contains the temperature at which THERM is asserted.
This allows the system to run as quietly as possible without affecting system performance.
PHTL = 0 ignores THERM assertions on the THERM pin. The local temperature operating point
register reflects its programmed value.
<4>
PHTR2
Read/Write
PHTR2 = 1 copies the Remote 2 current temperature to the Remote 2 operating point register if
THERM is asserted. The operating point contains the temperature at which THERM is asserted,
allowing the system to run as quietly as possible without affecting system performance.
PHTR2 = 0 ignores THERM assertions on the THERM pin. The Remote 2 operating point register
reflects its programmed value.
<5>
R1T
Read/Write
R1T = 1 enables dynamic T MIN control on the Remote 1 temperature channel. The chosen T MIN
value is dynamically adjusted based on the current temperature, operating point, and high and low
limits for the zone.
R1T = 0 disables dynamic T MIN control. The T MIN value chosen is not adjusted, and the channel
behaves as described in the Fan Speed Control section.
<6>
LT
Read/Write
LT = 1 enables dynamic T MIN control on the local temperature channel. The chosen T MIN value is
dynamically adjusted based on the current temperature, operating point, and high and low limits for
the zone.
LT = 0 disables dynamic T MIN control. The T MIN value chosen is not adjusted, and the channel
behaves as described in the Fan Speed Control section.
<7>
R2T
Read/Write
R2T = 1 enables dynamic T MIN control on the Remote 2 temperature channel. The chosen T MIN
value is dynamically adjusted based on the current temperature, operating point, and high and low
limits for the zone.
R2T = 0 disables dynamic T MIN control. The T MIN value chosen is not adjusted, and the channel
behaves as described in the Fan Speed Control section.
1. This register becomes a read-only register when the Configuration Register 1 LOCK bit is set to 1. Any subsequent attempts to write to this
register fail.
http://onsemi.com
56
相关PDF资料
PDF描述
ADT7468ZEVB BOARD EVAL FOR ADT7468
ADT7473ZEVB BOARD EVALUATION FOR ADT7473
ADT7475EBZEVB BOARD EVALUATION FOR ADT7475
ADT7476EBZEVB BOARD EVALUATION FOR ADT7476
ADT7490ZEVB BOARD EVALUATION FOR ADT7490
相关代理商/技术参数
参数描述
ADT7468 制造商:AD 制造商全称:Analog Devices 功能描述:dBCool⑩ Remote Thermal Controller and Voltage Monitor
ADT7468ARQ 功能描述:IC REMOTE THERMAL CTRLR 24-QSOP RoHS:否 类别:集成电路 (IC) >> PMIC - 热管理 系列:dBCool® 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADT7468ARQ-REEL 功能描述:IC REMOTE THERMAL CTRLR 24-QSOP RoHS:否 类别:集成电路 (IC) >> PMIC - 热管理 系列:dBCool® 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADT7468ARQ-REEL7 功能描述:IC REMOTE THERMAL CTRLR 24-QSOP RoHS:否 类别:集成电路 (IC) >> PMIC - 热管理 系列:dBCool® 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADT7468ARQZ 功能描述:板上安装温度传感器 RMT THRM CTR VLT MON RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor